Authentication bypass vulnerability in ACERA 1320 firmware ver.01.26 and earlier, and ACERA 1310 firmware ver.01.26 and earlier allows a network-adjacent unauthenticated attacker who can access the affected product to download configuration files and/or log files, and upload configuration files and/or firmware. They are affected when running in ST(Standalone) mode.
Lindy 42633 4-Port USB 2.0 Gigabit Network Server 2.078.000 devices allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R6700v3 1.0.4.120_10.0.91 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the httpd service. The issue results from incorrect string matching logic when accessing protected pages. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-15854.
Sensitive information disclosure in NetScaler Console
When a non-x86 platform is detected, cloud-init grants root access to a hardcoded url with a local IP address. To prevent this, cloud-init default configurations disable platform enumeration.
A limited authentication bypass vulnerability was discovered that could allow an attacker to achieve remote code execution and escalate privileges on the My Cloud devices. Addressed this vulnerability by changing access token validation logic and rewriting rule logic on PHP scripts.
An issue was discovered on NETGEAR Orbi Tri-Band Business WiFi Add-on Satellite (SRS60) AC3000 V2.5.1.106, Outdoor Satellite (RBS50Y) V2.5.1.106, and Pro Tri-Band Business WiFi Router (SRR60) AC3000 V2.5.1.106. The administrative SOAP interface allows an unauthenticated remote write of arbitrary Wi-Fi configuration data such as authentication details (e.g., the Web-admin password), network settings, DNS settings, system administration interface configuration, etc.
The WAVLINK Quantum D4G (WN531G3) running firmware version M31G3.V5030.200325 uses IP addresses to hold sessions and does not not use session tokens. Therefore, if an attacker changes their IP address to match the logged-in administrator's, or is behind the same NAT as the logged in administrator, session takeover is possible.
Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized remote attacker to gain administrative access by sending a specially crafted HTTP request.
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.
Insufficient security checks exist in the recovery procedure used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.43. An attacker who is in the same subnetwork of the camera or has remote administrator access can fully compromise the device by performing a firmware recovery using a custom image.
DrayTek Vigor310 devices through 4.3.2.6 use unencrypted HTTP for authentication requests.
Certain NETGEAR devices are affected by authentication bypass. This affects EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6120 before 1.0.0.32, EX6130 before 1.0.0.16, R6300v2 before 1.0.4.12, R6700 before 1.0.1.26, R6900 before 1.0.1.22, R7000 before 1.0.9.6, R7300DST before 1.0.0.52, R7900 before 1.0.1.12, R8000 before 1.0.3.24, R8500 before 1.0.2.74, and WNR2000v2 before 1.2.0.8.
A logic error in SiLabs Z/IP Gateway SDK 7.18.02 and earlier allows authentication to be bypassed, remote administration of Z-Wave controllers, and S0/S2 encryption keys to be recovered.
Improper authentication for some Intel(R) Server Boards, Server Systems and Compute Modules before version 1.59 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
Certain NETGEAR devices are affected by authentication bypass. This affects R6300v2 before 1.0.4.8, R6400 before 1.0.1.20, R6700 before 1.0.1.20, R6900 before 1.0.1.20, R7000 before 1.0.7.10, R7100LG before V1.0.0.32, R7300DST before 1.0.0.52, R7900 before 1.0.1.16, R8000 before 1.0.3.36, R8300 before 1.0.2.94, R8500 before 1.0.2.94, WNDR3400v3 before 1.0.1.12, and WNR3500Lv2 before 1.2.0.40.
Improper authentication for some Intel(R) Server Boards, Server Systems and Compute Modules before version 1.59 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
Certain NETGEAR devices are affected by authentication bypass. This affects D6220 before 1.0.0.28, D6400 before 1.0.0.60, D8500 before 1.0.3.29, R6250 before 1.0.4.8, R6400 before 1.0.1.22, R6400v2 before 1.0.2.32, R7100LG before 1.0.0.32, R7300DST before 1.0.0.52, R8300 before 1.0.2.94, and R8500 before 1.0.2.100.
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.
Waybox Enel X web management API authentication could be bypassed and provide administrator’s privileges over the Waybox system.
A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation.
CWE-287: Improper Authentication vulnerability exists that could cause unauthorized tampering of device configuration over NFC communication.
The Bluetooth module of some Huawei Smart Screen products has an identity authentication bypass vulnerability. Successful exploitation of this vulnerability may allow attackers to access restricted functions. Successful exploitation of this vulnerability may allow attackers to access restricted functions.
A vulnerability was found in SATO CL4NX-J Plus 1.13.2-u455_r2. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component WebConfig. The manipulation leads to improper authentication. The attack needs to be done within the local network. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-241027.
A vulnerability in the mesh code of Cisco Wireless LAN Controller (WLC) software could allow an unauthenticated, remote attacker to impersonate a WLC in a meshed topology. The vulnerability is due to insufficient authentication of the parent access point in a mesh configuration. An attacker could exploit this vulnerability by forcing the target system to disconnect from the correct parent access point and reconnect to a rogue access point owned by the attacker. An exploit could allow the attacker to control the traffic flowing through the impacted access point or take full control of the target system. This vulnerability affects the following products running a vulnerable version of Wireless LAN Controller software and configured for meshed mode: Cisco 8500 Series Wireless Controller, Cisco 5500 Series Wireless Controller, Cisco 2500 Series Wireless Controller, Cisco Flex 7500 Series Wireless Controller, Cisco Virtual Wireless Controller, Wireless Services Module 2 (WiSM2). Note that additional configuration is needed in addition to upgrading to a fixed release. Cisco Bug IDs: CSCuc98992 CSCuu14804.
Certain NETGEAR devices are affected by authentication bypass. This affects R6300v2 before 1.0.4.8, PLW1000v2 before 1.0.0.14, and PLW1010v2 before 1.0.0.14.
Certain NETGEAR devices are affected by authentication bypass. This affects D6200 before 1.1.00.24, R6700v2 before 1.1.0.42, R6800 before 1.1.0.42, and R6900v2 before 1.1.0.42.
A vulnerability in the Netgear DGN2200 router with firmware version v1.0.0.46 and earlier permits unauthorized individuals to bypass the authentication. When adding "?x=1.gif" to the the requested url, it will be recognized as passing the authentication.
An issue was discovered in Victure RX1800 WiFi 6 Router (software EN_V1.0.0_r12_110933, hardware 1.0) devices. A remote attacker (in proximity to a Wi-Fi network) can derive the default Wi-Fi PSK value via the last 4 octets of the BSSID.
An incorrect authorization vulnerability exists in multiple WSO2 products due to a business logic flaw in the account recovery-related SOAP admin service. A malicious actor can exploit this vulnerability to reset the password of any user account, leading to a complete account takeover, including accounts with elevated privileges. This vulnerability is exploitable only through the account recovery SOAP admin services exposed via the "/services" context path in affected products. The impact may be reduced if access to these endpoints has been restricted based on the "Security Guidelines for Production Deployment" by disabling exposure to untrusted networks.
There is no account authentication and permission check logic in the firmware and existing apps of SiHAS's SGW-300, ACM-300, GCM-300, so unauthorized users can remotely control the device.
An issue was discovered on Victure RX1800 WiFi 6 Router (software EN_V1.0.0_r12_110933, hardware 1.0) devices. The TELNET service is enabled by default with admin/admin as default credentials and is exposed over the LAN. The allows attackers to execute arbitrary commands with root-level permissions. Device setup does not require this password to be changed during setup in order to utilize the device. (However, the TELNET password is dictated by the current GUI password.)
Improper authentication in socket services for some Intel(R) Server Boards, Server Systems and Compute Modules before version 2.45 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
OpenBlocks IoT VX2 prior to Ver.4.0.0 (Ver.3 Series) allows an attacker on the same network segment to bypass authentication and to initialize the device via unspecified vectors.
NETGEAR DGN2200v1 devices before v1.0.0.60 mishandle HTTPd authentication (aka PSV-2020-0363, PSV-2020-0364, and PSV-2020-0365).