An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. Unauthenticated remote command execution can occur via the management portal.
Telepad allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
PC Keyboard allows remote unauthenticated users to send instructions to the server to execute arbitrary code without any previous authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
The default configuration of Lazy Mouse does not require a password, allowing remote unauthenticated users to execute arbitrary code with no prior authorization or authentication. CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
An issue discovered in Shenzhen Zhiboton Electronics ZBT WE1626 Router v 21.06.18 allows attackers to escalate privileges via WGET command to the Network Diagnosis endpoint.
The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.
In the default configuration of Apache SOAP, an RPCRouterServlet is available without authentication. This gives an attacker the possibility to invoke methods on the classpath that meet certain criteria. Depending on what classes are available on the classpath this might even lead to arbitrary remote code execution. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
authentik is an open-source identity provider. Versions prior to 2022.11.2 and 2022.10.2 are vulnerable to unauthorized user creation and potential account takeover. With the default flows, unauthenticated users can create new accounts in authentik. If a flow exists that allows for email-verified password recovery, this can be used to overwrite the email address of admin accounts and take over their accounts. authentik 2022.11.2 and 2022.10.2 fix this issue. As a workaround, a policy can be created and bound to the `default-user-settings-flow flow` with the contents `return request.user.is_authenticated`.
The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
KubeView through 0.1.31 allows attackers to obtain control of a Kubernetes cluster because api/scrape/kube-system does not require authentication, and retrieves certificate files that can be used for authentication as kube-admin. NOTE: the vendor's position is that KubeView was a "fun side project and a learning exercise," and not "very secure."
An issue was discovered in BACKCLICK Professional 5.9.63. User authentication for accessing the CORBA back-end services can be bypassed.
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Multiple W&T products of the ComServer Series are prone to an authentication bypass. An unathenticated remote attacker, can log in without knowledge of the password by crafting a modified HTTP GET Request.
A vulnerability classified as critical was found in SourceCodester Book Store Management System 1.0. This vulnerability affects unknown code of the file /bsms_ci/index.php. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-214588.
The SMS Alert Order Notifications – WooCommerce plugin for WordPress is vulnerable to privilege escalation via account takeover in all versions up to, and including, 3.7.9. This is due to the plugin using the Host header to determine if the plugin is in a playground environment. This makes it possible for unauthenticated attackers to spoof the Host header to make the OTP code "1234" and authenticate as any user, including administrators.
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
A missing authentication for critical function vulnerability [CWE-306] in FortiPresence infrastructure server before version 1.2.1 allows a remote, unauthenticated attacker to access the Redis and MongoDB instances via crafted authentication requests.
By default, the Packet Power Monitoring and Control Web Interface do not enforce authentication mechanisms. This vulnerability could allow unauthorized users to access and manipulate monitoring and control functions.
A vulnerability has been found in SourceCodester Sanitization Management System 1.0 and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The identifier VDB-212017 was assigned to this vulnerability.
An authentication bypass in the admin web console of Ivanti CSA before 5.0.3 allows a remote unauthenticated attacker to gain administrative access
This vulnerability allows remote attackers to bypass authentication on affected installations of Ivanti Avalanche. Authentication is not required to exploit this vulnerability. The specific flaw exists within the SetSettings class. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-15919.
Missing authentication for critical function vulnerability in UNIMO Technology digital video recorders (UDR-JA1004/JA1008/JA1016 firmware versions v1.0.20.13 and earlier, and UDR-JA1016 firmware versions v2.0.20.13 and earlier) allows a remote unauthenticated attacker to execute an arbitrary OS command by sending a specially crafted request to the affected device web interface.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of BMC Track-It! 20.21.2.109. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authorization of HTTP requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-16709.
A vulnerability has been found in TOTOLINK T6 4.1.5cu.748_B20211015 and classified as critical. Affected by this vulnerability is the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument telnet_enabled with the input 1 leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Web page which "wizardpwd.asp" ALLNET Router model WR0500AC is prone to Authorization bypass vulnerability – the password, located at "admin" allows changing the http[s]://wizardpwd.asp/cgi-bin. Does not validate the user's identity and can be accessed publicly.
Authentication Bypass vulnerability in miniOrange OAuth 2.0 client for SSO plugin <= 1.11.3 at WordPress.
HGiga EIP product lacks ineffective access control in certain pages that allow attackers to access database or perform privileged functions.
CVE-2024-10386 IMPACT An authentication vulnerability exists in the affected product. The vulnerability could allow a threat actor with network access to send crafted messages to the device, potentially resulting in database manipulation.
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port.
Improper Access Control, Missing Authorization, Incorrect Authorization, Incorrect Permission Assignment for Critical Resource, Missing Authentication, Weak Authentication, Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Talya Informatics Elektraweb allows Exploiting Incorrectly Configured Access Control Security Levels, Manipulating Web Input to File System Calls, Embedding Scripts within Scripts, Malicious Logic Insertion, Modification of Windows Service Configuration, Malicious Root Certificate, Intent Spoof, WebView Exposure, Data Injected During Configuration, Incomplete Data Deletion in a Multi-Tenant Environment, Install New Service, Modify Existing Service, Install Rootkit, Replace File Extension Handlers, Replace Trusted Executable, Modify Shared File, Add Malicious File to Shared Webroot, Run Software at Logon, Disable Security Software.This issue affects Elektraweb: before v17.0.68.
Access to the Advantech iView versions prior to v5.7.03.6112 configuration are missing authentication, which may allow an unauthorized attacker to change the configuration and obtain code execution.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users.
Missing authentication for critical function in DAP-1880AC firmware version 1.21 and earlier allows a remote attacker to login to the device as an authenticated user without the access privilege via unspecified vectors.
ASUS Armoury Crate has a vulnerability in arbitrary file write and allows remote attackers to access or modify arbitrary files by sending specific HTTP requests without permission.
Multiple vulnerabilities in Cisco Application Services Engine could allow an unauthenticated, remote attacker to gain privileged access to host-level operations or to learn device-specific information, create diagnostic files, and make limited configuration changes. For more information about these vulnerabilities, see the Details section of this advisory.
Certain NETGEAR devices are affected by authentication bypass. This affects WAC505 before 5.0.0.17 and WAC510 before 5.0.0.17.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A cfm UDP service listening on port 65002 allows remote, unauthenticated exfiltration of administrative credentials.
Trend Micro Apex One (2019), OfficeScan XG and Worry-Free Business Security (9.0, 9.5, 10.0) server contains a vulnerable service DLL file that could allow a remote attacker to execute arbitrary code on affected installations with SYSTEM level privileges. Authentication is not required to exploit this vulnerability.
In Apache Spark 2.4.5 and earlier, a standalone resource manager's master may be configured to require authentication (spark.authenticate) via a shared secret. When enabled, however, a specially-crafted RPC to the master can succeed in starting an application's resources on the Spark cluster, even without the shared key. This can be leveraged to execute shell commands on the host machine. This does not affect Spark clusters using other resource managers (YARN, Mesos, etc).
D-Link DIR-822+ V1.0.2 contains a login bypass in the HNAP1 interface, which allows attackers to log in to administrator accounts with empty passwords.
Improper Authentication vulnerability in Abdul Hakeem Build App Online allows Privilege Escalation.This issue affects Build App Online: from n/a through 1.0.19.
Missing Authentication for Critical Function in GitHub repository ikus060/rdiffweb prior to 2.5.0a6.
SAP Solution Manager (User Experience Monitoring), version- 7.2, due to Missing Authentication Check does not perform any authentication for a service resulting in complete compromise of all SMDAgents connected to the Solution Manager.
A ZTE product is impacted by the improper access control vulnerability. Due to lack of an authentication protection mechanism in the program, attackers could use this vulnerability to gain access right through brute-force attacks. This affects: <ZXONE 19700 SNPE><ZXONE8700V1.40R2B13_SNPE>
Standalone clients connecting to SAP NetWeaver AS Java via P4 Protocol, versions (SAP-JEECOR 7.00, 7.01; SERVERCOR 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50; CORE-TOOLS 7.00, 7.01, 7.02, 7.05, 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50) do not perform any authentication checks for operations that require user identity leading to Authentication Bypass.
A vulnerability exists allowing attackers, when present in the same network segment as ClearPass' management interface, to make changes to certain databases in ClearPass by crafting HTTP packets. As a result of this attack, a possible complete cluster compromise might occur. Resolution: Fixed in 6.7.13, 6.8.4, 6.9.0 and higher.
The ClearPass Policy Manager web interface is affected by a vulnerability that leads to authentication bypass. Upon successful bypass an attacker could then execute an exploit that would allow to remote command execution in the underlying operating system. Resolution: Fixed in 6.7.13-HF, 6.8.5-HF, 6.8.6, 6.9.1 and higher.
The router console is accessible without authentication at "data" field, and while a user needs to be logged in in order to modify the configuration, the session state is shared. If any other user is currently logged in, the anonymous user can execute commands in the context of the authenticated one. If the logged in user has administrative privileges, it is possible to use webadmin service configuration commands to create a new admin user with a chosen password.
The MStore API plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.1.5. This is due to unrestricted access to the 'register' and 'update_user_profile' routes. This makes it possible for unauthenticated attackers to create new administrator accounts, delete existing administrator accounts, or escalate privileges on any account.