Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.
An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
Gladinet CentreStack through 16.1.10296.56315 (fixed in 16.4.10315.56368) has a deserialization vulnerability due to the CentreStack portal's hardcoded machineKey use, as exploited in the wild in March 2025. This enables threat actors (who know the machineKey) to serialize a payload for server-side deserialization to achieve remote code execution. NOTE: a CentreStack admin can manually delete the machineKey defined in portal\web.config.
Calibre-Web 0.6.6 allows authentication bypass because of the 'A0Zr98j/3yX R~XHH!jmN]LWX/,?RT' hardcoded secret key.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) use undocumented accounts.
mcollective has a default password set at install
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Hardcoded Credentials exist in the APK for Ports 9091 and 9092. The dashcam's Android application contains hardcoded credentials that allow unauthorized access to device settings through ports 9091 and 9092. These credentials, stored in cleartext, can be exploited by an attacker who gains access to the dashcam's network.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.
An issue was discovered in the G-Net GNET APK 2.6.2. Hardcoded credentials exist in in APK for ports 9091 and 9092. The GNET mobile application contains hardcoded credentials that provide unauthorized access to the dashcam's API endpoints on ports 9091 and 9092. Once the GNET SSID is connected to, the attacker sends a crafted authentication command with TibetList and 000000 to list settings of the dashcam at port 9091. There's a separate set of credentials for port 9092 (stream) that is also exposed in cleartext: admin + tibet. For settings, the required credentials are adim + 000000.
The management tool in MyLittleAdmin 3.8 allows remote attackers to execute arbitrary code because machineKey is hardcoded (the same for all customers' installations) in web.config, and can be used to send serialized ASP code.
Hard-coded credentials in AmosConnect 8 allow remote attackers to gain full administrative privileges, including the ability to execute commands on the Microsoft Windows host platform with SYSTEM privileges by abusing AmosConnect Task Manager.
QNAP F_VioCard 2312 and F_VioGate 2308 have hardcoded entries in authorized_keys files. NOTE: 1. All active models are not affected. The last affected model was EOL since 2010. 2. The legacy authorization mechanism is no longer adopted in all active models
The Jitsi Meet (aka docker-jitsi-meet) stack on Docker before stable-4384-1 uses default passwords (such as passw0rd) for system accounts.
An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
OpsRamp Gateway before 7.0.0 has a backdoor account vadmin with the password 9vt@f3Vt that allows root SSH access to the server. This issue has been resolved in OpsRamp Gateway firmware version 7.0.0 where an administrator and a system user accounts are the only available user accounts for the gateway appliance.
OpenC3 COSMOS v6.0.0 was discovered to contain hardcoded credentials for the Service Account.
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
Hardcoded credentials are discovered within the application's source code, creating a potential security risk for unauthorized access.
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. During the installation, it sets up administrative access by default with the account admin and password 0000. After the installation, users/admins are not prompted to change this password.
Arbitrary code execution vlnerability in Operation bridge Manager, Application Performance Management and Operations Bridge (containerized) vulnerability in Micro Focus products products Operation Bridge Manager, Operation Bridge (containerized) and Application Performance Management. The vulneravility affects: 1.) Operation Bridge Manager versions 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, 10.63,10.62, 10.61, 10.60, 10.12, 10.11, 10.10 and all earlier versions. 2.) Operations Bridge (containerized) 2020.05, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05. 2018.02 and 2017.11. 3.) Application Performance Management versions 9,51, 9.50 and 9.40 with uCMDB 10.33 CUP 3. The vulnerability could allow Arbitrary code execution.
Because of hard-coded SSH keys for the root user in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series, Kami7B, an attacker may remotely log in through SSH.
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. We have confirmed this flaw in MiR100 and MiR200 but it might also apply to MiR250, MiR500 and MiR1000.
MeterSphere is a one-stop open source continuous testing platform, covering functions such as test tracking, interface testing, UI testing and performance testing. The Selenium VNC config used in Metersphere is using a weak password by default, attackers can login to vnc and obtain high permissions. This issue has been addressed in version 2.10.7 LTS. Users are advised to upgrade. There are no known workarounds for this vulnerability.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
NETSCOUT nGeniusPULSE 3.8 has a Hardcoded Cryptographic Key.
Vue Vben Admin 2.10.1 allows unauthorized login to the backend due to an issue with hardcoded credentials.
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the axzyxel password for the livedbuser account.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
N.V.K.INTER CO., LTD. (NVK) iBSG v3.5 was discovered to contain a hardcoded root password which allows attackers to login with root privileges via the SSH service.
Linear eMerge E3-Series devices have Hard-coded Credentials.
Use of Hard-coded Credentials vulnerability in FortiRecorder all versions below 2.7.4 may allow an unauthenticated attacker with knowledge of the aforementioned credentials and network access to FortiCameras to take control of those, provided they are managed by a FortiRecorder device.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the wbboEZ4BN3ssxAfM hardcoded password for the debian-sys-maint account.
HCL AppScan Standard Edition 9.0.3.13 and earlier uses hard-coded credentials which can be exploited by attackers to get unauthorized access to the system.
An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. All dashcams were shipped with the same default credentials of 12345678, which creates an insecure-by-default condition. For users who change their passwords, it's limited to 8 characters. These short passwords can be cracked in 8 hours via low-end commercial cloud resources.
The affected devices use publicly available default credentials with administrative privileges.
Unsafe storage of AD credentials in Ivanti DSM netinst 5.1 due to a static, hard-coded encryption key.
JBL soundbar multibeam 5.1 - CWE-798: Use of Hard-coded Credentials
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.
An unauthenticated remote attacker can use hard-coded credentials to gain full administration privileges on the affected product.
Control ID IDSecure 4.7.26.0 and prior uses a hardcoded cryptographic key in order to sign and verify JWT session tokens, allowing attackers to sign arbitrary session tokens and bypass authentication.
A vulnerability classified as critical was found in OTCMS up to 6.62. This vulnerability affects unknown code. The manipulation of the argument username/password with the input admin leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-231508.
Synel SYnergy Fingerprint Terminals - CWE-798: Use of Hard-coded Credentials
MXsecurity version 1.0 is vulnearble to hardcoded credential vulnerability. This vulnerability has been reported that can be exploited to craft arbitrary JWT tokens and subsequently bypass authentication for web-based APIs.
Dromara Lamp-Cloud before v3.8.1 was discovered to use a hardcoded cryptographic key when creating and verifying a Json Web Token. This vulnerability allows attackers to authenticate to the application via a crafted JWT token.
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed.
All versions of the qBittorrent client through 4.5.5 use default credentials when the web user interface is enabled. The administrator is not forced to change the default credentials. As of 4.5.5, this issue has not been fixed. A remote attacker can use the default credentials to authenticate and execute arbitrary operating system commands using the "external program" feature in the web user interface. This was reportedly exploited in the wild in March 2023.
Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device.
Rocket Software UniData versions prior to 8.2.4 build 3003 and UniVerse versions prior to 11.3.5 build 1001 or 12.2.1 build 2002 suffer from an authentication bypass vulnerability, where a special username with a deterministic password can be leveraged to bypass authentication checks and execute OS commands as the root user.