Microsoft SQL Server Elevation of Privilege Vulnerability
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to download files by using a therefore unpriviledged account via the REST interface.
Infoblox NIOS through 8.6.4 has Improper Authentication for Grids.
Lexmark products through 2023-01-10 have Improper Control of Interaction Frequency.
A security misconfiguration vulnerability exists in the Zyxel LTE3316-M604 firmware version V2.00(ABMP.6)C0 due to a factory default misconfiguration intended for testing purposes. A remote attacker could leverage this vulnerability to access an affected device using Telnet.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.34), Mendix Applications using Mendix 8 (All versions < V8.18.23), Mendix Applications using Mendix 9 (All versions < V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions < V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.15). Some of the Mendix runtime API’s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors.
Improper Access Control in SICK FTMg AIR FLOW SENSOR with Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows an unprivileged remote attacker to gain unauthorized access to data fields by using a therefore unpriviledged account via the REST interface.
In MISP 2.4.167, app/Controller/Component/ACLComponent.php has incorrect access control for the decaying import function.
Baicells Nova 227, Nova 233, and Nova 243 LTE TDD eNodeB devices with firmware through RTS/RTD 3.7.11.3 have hardcoded credentials that are easily discovered and can be used by remote attackers to authenticate via ssh. (The credentials are stored in the firmware, encrypted by the crypt function.)
An incorrect access control vulnerability in Rubrik CDM versions prior to 9.1.2-p1, 9.0.3-p6 and 8.1.3-p12, allows an attacker with network access to execute arbitrary code.
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a hardcoded password for telnet in /web_cste/cgi-bin/product.ini, which allows attackers to log in as root.
Improper access control vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to bypass access restriction and obtain the server certificate including the private key of the product.
LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.
Improper access control vulnerability in SS1 Ver.13.0.0.40 and earlier and Rakuraku PC Cloud Agent Ver.2.1.8 and earlier allows a remote attacker to bypass access restriction and download an arbitrary file of the directory where the product runs. As a result of exploiting this vulnerability with CVE-2023-22336 and CVE-2023-22344 vulnerabilities together, it may allow a remote attacker to execute an arbitrary code with SYSTEM privileges by sending a specially crafted script to the affected device.
Axiros AXESS Auto Configuration Server (ACS) 4.x and 5.0.0 is affected by an Incorrect Access Control vulnerability. An authorization bypass allows remote attackers to achieve unauthenticated remote code execution.
An issue was discovered in Italtel Embrace 1.6.4. The web application does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
An issue in flusity CMS v2.33 allows a remote attacker to execute arbitrary code via the add_addon.php component.
A vulnerability was found in SourceCodester Music Gallery Site 1.0. It has been rated as critical. This issue affects some unknown processing of the file Users.php of the component POST Request Handler. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-221633 was assigned to this vulnerability.
A vulnerability was found in SourceCodester Online Food Ordering System 2.0 and classified as critical. Affected by this issue is some unknown functionality of the file /fos/admin/ajax.php?action=save_settings of the component POST Request Handler. The manipulation leads to improper access controls. The attack may be launched remotely. VDB-223214 is the identifier assigned to this vulnerability.
Improper Access Control in GitHub repository answerdev/answer prior to 1.0.4.
An unauthenticated attacker in SAP NetWeaver AS for Java - version 7.50, due to improper access control, can attach to an open interface and make use of an open naming and directory API to access services which can be used to perform unauthorized operations affecting users and data on the current system. This could allow the attacker to have full read access to user data, make modifications to user data, and make services within the system unavailable.
The Alfresco Reset Password add-on before version 1.2.0 relies on untrusted inputs in a security decision. Intruders can get admin's access to the system using the vulnerability in the project. Impacts all servers where this add-on is installed. The problem is fixed in version 1.2.0
COMFAST (Shenzhen Sihai Zhonglian Network Technology Co., Ltd) CF-WR623N Router firmware V2.3.0.1 is vulnerable to Incorrect Access Control.
Improper Access Control in GitHub repository ikus060/rdiffweb prior to 2.5.5.
Devices ekorCCP and ekorRCI are vulnerable due to access to the FTP service using default credentials. Exploitation of this vulnerability can allow an attacker to modify critical files that could allow the creation of new users, delete or modify existing users, modify configuration files, install rootkits or backdoors.
Incorrect access control in the component /api/user/manager of One v1.0 allows attackers to access sensitive information via a crafted payload.
The Web interface of Evolution Controller Versions 2.04.560.31.03.2024 and below contains poorly configured access control on DESKTOP_EDIT_USER_GET_ABACARD_FIELDS, allowing for an unauthenticated attacker to return the abacard field of any user
An issue was discovered in Samsung Mobile Processor, Wearable Processor, and Modem Exynos 980, Exynos 990, Exynos 1080, Exynos 2100, Exynos 2200, Exynos 1280, Exynos 1380, Exynos 1330, Exynos 2400, Exynos Modem 5123, Exynos Modem 5300. The baseband software does not properly check states specified by the RRC (Radio Resource Control) module. This can lead to disclosure of sensitive information.
Siklu TG Terragraph devices before 2.1.1 allow attackers to discover valid, randomly generated credentials via GetCredentials.
An attacker with weak credentials could access the TCP port via an open FTP port, allowing an attacker to read sensitive files and write to remotely executable directories.
The Web interface of Evolution Controller Versions 2.04.560.31.03.2024 and below contains poorly configured access control on MOBILE_GET_USERS_LIST, allowing for an unauthenticated attacker to enumerate all users and their access levels
Incorrect access control in the component /user/list of production_ssm v0.0.1-SNAPSHOT allows attackers to access sensitive information via a crafted payload.
In Ampere AltraMax and Ampere Altra before 2.10c, improper access controls allows the OS to reinitialize a disabled root complex.
The Web interface of Evolution Controller Versions 2.04.560.31.03.2024 and below contains poorly configured access control on DESKTOP_EDIT_USER_GET_PIN_FIELDS, allowing for an unauthenticated attacker to return the pin value of any user
https://www.hillstonenet.com.cn/ Hillstone Firewall SG-6000 <= 5.0.4.0 is vulnerable to Incorrect Access Control. There is a permission bypass vulnerability in the Hillstone WEB application firewall. An attacker can enter the background of the firewall with super administrator privileges through a configuration error in report.m.
Siklu TG Terragraph devices before approximately 2.1.1 have a hardcoded root password that has been revealed via a brute force attack on an MD5 hash. It can be used for "debug login" by an admin. NOTE: the vulnerability is not fixed by the 2.1.1 firmware; instead, it is fixed in newer hardware, which would typically be used with firmware 2.1.1 or later.
The Web interface of Evolution Controller Versions 2.04.560.31.03.2024 and below contains poorly configured access control on DESKTOP_EDIT_USER_GET_CARD, allowing for an unauthenticated attacker to return the card value data of any user
The Web interface of Evolution Controller Versions 2.04.560.31.03.2024 and below contains poorly configured access control on DESKTOP_EDIT_USER_GET_KEYS_FIELDS, allowing for an unauthenticated attacker to return the keys value of any user
Claris International has resolved an issue of potentially allowing unauthorized access to records stored in databases hosted on FileMaker Server. This issue has been fixed in FileMaker Server 20.3.2 by validating transactions before replying to client requests.
Alldata V0.4.6 is vulnerable to Insecure Permissions. Using users (test) can query information about the users in the system.
Jenkins Compuware Topaz for Total Test Plugin 2.4.8 and earlier implements an agent/controller message that does not limit where it can be executed, allowing attackers able to control agent processes to read arbitrary files on the Jenkins controller file system.
A vulnerability was found in SourceCodester E-Commerce System 1.0. It has been rated as critical. Affected by this issue is some unknown functionality of the file /ecommerce/admin/user/controller.php?action=edit of the component Username Handler. The manipulation of the argument USERID leads to improper access controls. The attack may be launched remotely. VDB-223550 is the identifier assigned to this vulnerability.
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
An issue in Advanced Plugins ultimateimagetool module for PrestaShop before v.2.2.01, allows a remote attacker to escalate privileges and obtain sensitive information via Improper Access Control.
Vulnerability of permission control in the window module. Successful exploitation of this vulnerability may affect confidentiality.
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. The debug port accessible via TCP (a qconn service) lacks access control.
RCE-Remote Command Execution vulnerability in Apache HugeGraph-Server.This issue affects Apache HugeGraph-Server: from 1.0.0 before 1.3.0 in Java8 & Java11 Users are recommended to upgrade to version 1.3.0 with Java11 & enable the Auth system, which fixes the issue.
An unauthorized user could be able to read any file on the system, potentially exposing sensitive information.
Bypass vulnerability in Quiz And Survey Master plugin <= 7.3.10 on WordPress.
In Mahara 21.04 before 21.04.7, 21.10 before 21.10.5, 22.04 before 22.04.3, and 22.10 before 22.10.0, embedded images are accessible without a sufficient permission check under certain conditions.