Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges.
Path traversal attack is possible and write outside of the intended directory and may access sensitive information. If a file name is specified that already exists on the file system, then the original file will be overwritten.
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution.
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation.
Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.
Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. An authenticated attacker may be able to exploit this issue to cause delay in the targeted product.
Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.
SQL injection vulnerability exists in GetDIAE_astListParameters.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.
SQL injection vulnerability exists in the script DIAE_tagHandler.ashx.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.
The affected product DIAEnergie (versions prior to v1.9.03.001) contains improper authorization, which could allow an unauthorized user to bypass authorization and access privileged functionality.
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution.
A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator.
SQL injection vulnerability exists in GetDIAE_usListParameters.
SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
Privileges are not fully verified server-side, which can be abused by a user with limited privileges to bypass authorization and access privileged functionality.
SQL injection vulnerability exists in the script Handler_CFG.ashx.
SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
Delta Electronics DVW-W02W2-E2 1.5.0.10 is vulnerable to Command Injection via Crafted URL.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation.
SQL injection vulnerability exists in GetDIAE_unListParameters.
SQL injection vulnerability exists in GetDIAE_slogListParameters.
SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to path traversal attacks, which may allow an attacker to write arbitrary files to locations on the file system.
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
It is possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtain plaintext credentials, or perform NTLM relaying.
OpenClaw versions prior to 2026.2.14 contain a path traversal vulnerability in apply_patch that allows attackers to write or delete files outside the configured workspace directory. When apply_patch is enabled without filesystem sandbox containment, attackers can exploit crafted paths including directory traversal sequences or absolute paths to escape workspace boundaries and modify arbitrary files.
A directory traversal vulnerability exists in the HelpdeskActions.aspx edittemplate functionality of Lansweeper lansweeper 10.1.1.0. A specially-crafted HTTP request can lead to arbitrary file upload. An attacker can send an HTTP request to trigger this vulnerability.
Dataease is an open source data visualization analysis tool. Prior to 2.10.20, By controlling the IniFile parameter, an attacker can force the JDBC driver to load an attacker-controlled configuration file. This configuration file can inject dangerous JDBC properties, leading to remote code execution. The Redshift JDBC driver execution flow reaches a method named getJdbcIniFile. The getJdbcIniFile method implements an aggressive automatic configuration file discovery mechanism. If not explicitly restricted, it searches for a file named rsjdbc.ini. In a JDBC URL context, users can explicitly specify the configuration file via URL parameters, which allows arbitrary files on the server to be loaded as JDBC configuration files. Within the Redshift JDBC driver properties, the parameter IniFile is explicitly supported and used to load an external configuration file. This vulnerability is fixed in 2.10.20.
The Advanced Members for ACF plugin for WordPress is vulnerable to arbitrary file deletion due to insufficient file path validation in the create_crop function in all versions up to, and including, 1.2.5. This makes it possible for authenticated attackers, with Subscriber-level access and above, to delete arbitrary files on the server, which can easily lead to remote code execution when the right file is deleted (such as wp-config.php). The vulnerability was partially patched in version 1.2.5.
The WordPress File Upload Free and Pro WordPress plugins before 4.16.3 allow users with a role as low as Contributor to perform path traversal via a shortcode argument, which can then be used to upload a PHP code disguised as an image inside the auto-loaded directory of the plugin, resulting in arbitrary code execution.
MyBB 1.8.32 contains a chained vulnerability that allows authenticated administrators to bypass avatar upload restrictions and execute arbitrary code. Attackers can modify upload path settings, upload a malicious PHP-embedded image file, and execute commands through the language configuration editing interface.
A vulnerability has been found in HummerRisk up to 1.5.0. This issue affects the function extractTarGZ/extractZip of the file hummer-common/hummer-common-core/src/main/java/com/hummer/common/core/utils/CommandUtils.java of the component Archive Extraction. The manipulation leads to path traversal. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Vitess is a database clustering system for horizontal scaling of MySQL. Prior to versions 23.0.3 and 22.0.4, anyone with read/write access to the backup storage location (e.g. an S3 bucket) can manipulate backup manifest files so that files in the manifest — which may be files that they have also added to the manifest and backup contents — are written to any accessible location on restore. This is a common path traversal security issue. This can be used to provide that attacker with unintended/unauthorized access to the production deployment environment — allowing them to access information available in that environment as well as run any additional arbitrary commands there. Versions 23.0.3 and 22.0.4 contain a patch. No known workarounds are available.
LORIS (Longitudinal Online Research and Imaging System) is a self-hosted web application that provides data- and project-management for neuroimaging research. Prior to versions 26.0.5, 27.0.2, and 28.0.0, an authenticated user with sufficient privileges can exploit a path traversal vulnerability to upload a malicious file to an arbitrary location on the server. Once uploaded, the file can be used to achieve remote code execution (RCE). An attacker must be authenticated and have the appropriate permissions to exploit this issue. If the server is configured as read-only, remote code execution (RCE) is not possible; however, the malicious file upload may still be achievable. This problem is fixed in LORIS v26.0.5 and above, v27.0.2 and above, and v28.0.0 and above. As a workaround, LORIS administrators can disable the media module if it is not being used.