Hardcoded default root credentials exist on the ecobee3 lite 4.5.81.200 device. This allows a threat actor to gain access to the password-protected bootloader environment through the serial console.
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
An issue was discovered in Shinobi through ocean version 1. lib/auth.js has Incorrect Access Control. Valid API Keys are held in an internal JS Object. Therefore an attacker can use JS Proto Method names (such as constructor or hasOwnProperty) to convince the System that the supplied API Key exists in the underlying JS object, and consequently achieve complete access to User/Admin/Super API functions, as demonstrated by a /super/constructor/accounts/list URI.
An issue was discovered on FiberHome HG6245D devices through RP2613. The telnet daemon on port 23/tcp can be abused with the gpon/gpon credentials.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / 3UJUh2VemEfUtesEchEC2d2e credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / 1234 credentials for an ISP.
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
D-Link DSR-500N version 1.02 contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file.If an attacker succeeds in recovering the cleartext password of the identified hash value, he will be able to log in via SSH or Telnet and thus gain access to the underlying embedded Linux operating system on the device. Fixed in version 2.12/2. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
HejHome GKW-IC052 IP Camera contained a hard-coded credentials vulnerability. This issue allows remote attackers to operate the IP Camera.(reboot, factory reset, snapshot etc..)
IBM Security Verify Access Appliance 10.0.0 through 10.0.8 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0.
IBM Security Verify Access Appliance 10.0.0 through 10.0.8 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
The express install, which is the suggested way to install Puppet Enterprise, gives the user a URL at the end of the install to set the admin password. If they do not use that URL, there is an overlooked default password for the admin user. This was resolved in Puppet Enterprise 2019.0.3 and 2018.1.9.
Hard-coded credentials in AmosConnect 8 allow remote attackers to gain full administrative privileges, including the ability to execute commands on the Microsoft Windows host platform with SYSTEM privileges by abusing AmosConnect Task Manager.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.
HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded System Passwords that provide shell access.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
A use of hard-coded credentials (CWE-798) vulnerability in FortiPortal versions 5.2.5 and below, 5.3.5 and below, 6.0.4 and below, versions 5.1.x and 5.0.x may allow a remote and unauthenticated attacker to execute unauthorized commands as root by uploading and deploying malicious web application archive files using the default hard-coded Tomcat Manager username and password.
Dell RecoverPoint for Virtual Machines 6.0.x contains use of hard-coded credentials vulnerability. A Remote unauthenticated attacker could potentially exploit this vulnerability by gaining access to the source code, easily retrieving these secrets and reusing them to access the system leading to gaining access to unauthorized data.
Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism.
GarrettCom Magnum 6K and 10K managed switches contain an authentication bypass vulnerability that allows unauthenticated attackers to gain unauthorized access by exploiting a hardcoded string in the authentication mechanism. Attackers can bypass login controls to access administrative functions and sensitive switch configuration without valid credentials.
Use of hard-coded cryptographic key vulnerability in QSAN Storage Manager allows attackers to obtain users’ credentials and related permissions. Suggest contacting with QSAN and refer to recommendations in QSAN Document.
The vulnerability of hard-coded default credentials in QSAN SANOS allows unauthenticated remote attackers to obtain administrator’s permission and execute arbitrary functions. The referred vulnerability has been solved with the updated version of QSAN SANOS v2.1.0.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
A vulnerability was found in SICUNET Access Controller 0.32-05z. It has been classified as very critical. This affects an unknown part. The manipulation leads to weak authentication. It is possible to initiate the attack remotely.
A vulnerability in Brocade Network Advisor Version Before 14.3.1 could allow an unauthenticated, remote attacker to log in to the JBoss Administration interface of an affected system using an undocumented user credentials and install additional JEE applications.
Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key.
BB-ESWGP506-2SFP-T versions 1.01.09 and prior is vulnerable due to the use of hard-coded credentials, which may allow an attacker to gain unauthorized access and permit the execution of arbitrary code on the BB-ESWGP506-2SFP-T (versions 1.01.01 and prior).
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
D-Link DIR-620 devices, with a certain Rostelekom variant of firmware 1.0.37, have a hardcoded rostel account, which makes it easier for remote attackers to obtain access via a TELNET session.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded useradmin / 888888 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded f~i!b@e#r$h%o^m*esuperadmin / s(f)u_h+g|u credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded user / tattoo@home credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded awnfibre / fibre@dm!n credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / lnadmin credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / aisadmin credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains credentials for an ISP that equal the last part of the MAC address of the br0 interface.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded user / 888888 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded telecomadmin / nE7jA%5m credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / G0R2U1P2ag credentials for an ISP.
Certain NETGEAR devices are affected by a hardcoded password. This affects D3600 before 1.0.0.76 and D6000 before 1.0.0.76.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network.
D-Link COVR-2600R and COVR-3902 Kit before 1.01b05Beta01 use hardcoded credentials for telnet connection, which allows unauthenticated attackers to gain privileged access to the router, and to extract sensitive data or modify the configuration.
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
dirary0.js on D-Link DIR-140L, DIR-640L devices allows remote unauthenticated attackers to discover admin credentials.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.