mySCADA myPRO uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
IBM Flexible Service Processor (FSP) FW860.00 through FW860.B3, FW950.00 through FW950.C0, FW1030.00 through FW1030.61, FW1050.00 through FW1050.21, and FW1060.00 through FW1060.10 has static credentials which may allow network users to gain service privileges to the FSP.
Certain models of D-Link wireless routers do not properly validate user input in the telnet service, allowing unauthenticated remote attackers to use hard-coded credentials to log into telnet and inject arbitrary OS commands, which can then be executed on the device.
The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.
An exploitable Use of Hard-coded Credentials vulnerability exists in the Moxa AWK-3131A Wireless Access Point running firmware 1.1. The device operating system contains an undocumented, privileged (root) account with hard-coded credentials, giving attackers full control of affected devices.
Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A hard-coded account allows management-interface login with high privileges. The logged-in user can perform critical tasks and take full control of the device.
An authentication bypass vulnerability in the /web/um_open_telnet.cgi endpoint in Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below, allowing an attacker to remotely enable the Telnet service without authentication, bypassing security controls. The Telnet server is then accessible with hard-coded credentials, allowing attackers to gain administrative shell access and execute arbitrary commands on the device.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected device stores sensitive information in the firmware. This could allow an attacker to access and misuse this information, potentially impacting the device’s confidentiality, integrity, and availability.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
Austrian Archaeological Institute (AI) OpenAtlas v8.11.0 as discovered to contain a hardcoded Administrator password.
SAP Commerce, versions - 6.7, 1808, 1811, 1905, and SAP Commerce (Data Hub), versions - 6.7, 1808, 1811, 1905, allows an attacker to bypass the authentication and/or authorization that has been configured by the system administrator due to the use of Hardcoded Credentials.
IBM Security Verify Access 10.7 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 181395.
Dell EMC Networking S4100 and S5200 Series Switches manufactured prior to February 2020 contain a hardcoded credential vulnerability. A remote unauthenticated malicious user could exploit this vulnerability and gain administrative privileges.
IBM Security Guardium 11.2 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 196313.
The CS5000 Fire Panel is vulnerable due to a hard-coded password that runs on a VNC server and is visible as a string in the binary responsible for running VNC. This password cannot be altered, allowing anyone with knowledge of it to gain remote access to the panel. Such access could enable an attacker to operate the panel remotely, potentially putting the fire panel into a non-functional state and causing serious safety issues.
UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to gain administrative privileges to all UNI-NMS managed devices.
UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to read, manipulate and create entries in the managed database.
Trendnet AC2600 TEW-827DRU version 2.08B01 makes use of hardcoded credentials. It is possible to backup and restore device configurations via the management web interface. These devices are encrypted using a hardcoded password of "12345678".
In ZKT ZKBio CVSecurity 6.4.1_R an unauthenticated attacker can craft JWT token using the hardcoded secret to authenticate to the service console. NOTE: the Supplier disputes the significance of this report because the service console is typically only accessible from a local area network, and because access to the service console does not result in login access or data access in the context of the application software platform.
The Web Administrative Interface in Mobile Viewpoint Wireless Multiplex Terminal (WMT) Playout Server 20.2.8 and earlier has a default account with a password of "pokon."
Zumtobel Netlink CCD Onboard 3.74 - Firmware 3.80 was discovered to contain hardcoded credentials for the Administrator account.
Hardcoded manufacturer credentials and an OS command injection vulnerability in the /cgi-bin/mft/ directory on ABUS TVIP TVIP20050 LM.1.6.18, TVIP10051 LM.1.6.18, TVIP11050 MG.1.6.03.05, TVIP20550 LM.1.6.18, TVIP10050 LM.1.6.18, TVIP11550 MG.1.6.03, TVIP21050 MG.1.6.03, and TVIP51550 MG.1.6.03 cameras allow remote attackers to execute code as root.
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. There is an !j@l#y$z%x6x7q8c9z) password for the admin account to authenticate to the TELNET service.
Log files uploaded during troubleshooting by the Harmony SASE agent may have been accessible to unauthorized parties.
An issue was discovered in the box application on HiSilicon based IPTV/H.264/H.265 video encoders. Attackers can use hard-coded credentials in HTTP requests to perform any administrative task on the device including retrieving the device's configuration (with the cleartext admin password), and uploading a custom firmware update, to ultimately achieve arbitrary code execution.
In the DES implementation, the affected product versions use a default key for encryption. Successful exploitation allows an attacker to obtain sensitive information and gain access to the network elements that are managed by the affected products versions. This issue affects * FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; * UNEM product: UNEM R16A, UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C. List of CPEs: * cpe:2.3:a:hitachienergy:foxman-un:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
ShineLan-X contains a set of credentials for an FTP server was found within the firmware, allowing testers to establish an insecure FTP connection with the server. This may allow an attacker to replace legitimate files being deployed to devices with their own malicious versions, since the firmware signature verification is not enforced.
IBM Security Verify Access 10.0.0 through 10.0.9, 11.0.0, IBM Verify Identity Access Container 10.0.0 through 10.0.9, and 11.0.0, under certain configurations, contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
PTZOptics and possibly other ValueHD-based pan-tilt-zoom cameras use default, shared credentials for the administrative web interface.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version 20.0.2786 (VA/SaaS deployments) contain a default admin account and an installation‑time endpoint at `/admin/query/update_database.php` that can be accessed without authentication. An attacker who can reach the installation web interface can POST arbitrary `root_user` and `root_password` values, causing the script to replace the default admin credentials with attacker‑controlled ones. The script also contains hard‑coded SHA‑512 and SHA‑1 hashes of the default password, allowing the attacker to bypass password‑policy validation. As a result, an unauthenticated remote attacker can obtain full administrative control of the system during the initial setup. This vulnerability has been identified by the vendor as: V-2024-022 — Insecure Installation Credentials.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 22.0.951 and Application prior to 20.0.2368 (VA and SaaS deployments) contain shared, hardcoded SSH host private keys in the appliance image. The same private host keys (RSA, ECDSA, and ED25519) are present across installations, rather than being uniquely generated per appliance. An attacker who obtains these private keys (for example from one compromised appliance image or another installation) can impersonate the appliance, decrypt or intercept SSH connections to appliances that use the same keys, and perform man-in-the-middle or impersonation attacks against administrative SSH sessions. This vulnerability has been identified by the vendor as: V-2024-011 — Hardcoded SSH Host Key.
NVIDIA Isaac Launchable contains a vulnerability where an attacker could exploit a hard-coded credential issue. A successful exploit of this vulnerability might lead to code execution, escalation of privileges, denial of service, and data tampering.
The firmware of the PLANET Technology Corp NVR-915 and NVR-1615 before 2020-10-28 embeds default credentials for root access via telnet. By exposing telnet on the Internet, remote root access on the device is possible. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
This improper access control vulnerability in Helpdesk allows attackers to get control of QNAP Kayako service. Attackers can access the sensitive data on QNAP Kayako server with API keys. We have replaced the API key to mitigate the vulnerability, and already fixed the issue in Helpdesk 3.0.1 and later versions.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
IBM Concert 1.0.0 through 2.1.0 could allow a remote attacker to obtain sensitive information or perform unauthorized actions due to the use of hard coded user credentials.
D-Link DIR-600L Hardware Revision A1 (End-of-Life) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn35_dlwbr_dir600l" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches.
An issue was discovered on FiberHome HG6245D devices through RP2613. The password for the enable command is gpon.
D-Link DIR-600L Hardware Revision B1 (End-of-Life) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn61_dlwbr_dir600L" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches.
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
D-Link DVG-3104MS version 1.0.2.0.3, 1.0.2.0.4, and 1.0.2.0.4E contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file. As weak passwords have been used, the plaintext passwords can be recovered from the hash values. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
Yarbo firmware v2.3.9 contains hardcoded administrative credentials embedded in the firmware image. These credentials are identical across all devices running this firmware and cannot be changed or removed by end users, enabling trivial unauthorized access to device management interfaces by anyone who knows them.
IBM Spectrum Virtualize 8.2, 8.3, and 8.4 could allow an attacker to allow unauthorized access due to the reuse of support generated credentials. IBM X-Force ID: 212609.
An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
GateManager versions prior to 9.2c, The affected product contains a hard-coded credential for telnet, allowing an unprivileged attacker to execute commands as root.
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They contain two undocumented administrator accounts. The sftp and mofidev accounts are defined in /etc/passwd and the password is not unique across installations.