Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-39763

Summary
Assigner-talos
Assigner Org ID-b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b
Published At-14 Jan, 2025 | 14:21
Updated At-03 Nov, 2025 | 21:56
Rejected At-
Credits

Multiple OS command injection vulnerabilities exist in the internet.cgi set_add_routing() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists in the `gateway` POST parameter.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:talos
Assigner Org ID:b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b
Published At:14 Jan, 2025 | 14:21
Updated At:03 Nov, 2025 | 21:56
Rejected At:
▼CVE Numbering Authority (CNA)

Multiple OS command injection vulnerabilities exist in the internet.cgi set_add_routing() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists in the `gateway` POST parameter.

Affected Products
Vendor
WAVLINK Technology Ltd.Wavlink
Product
Wavlink AC3000
Versions
Affected
  • M33A8.V5030.210505
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.19.1CRITICAL
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Version: 3.1
Base score: 9.1
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Discovered by Lilith >_> of Cisco Talos.
Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://talosintelligence.com/vulnerability_reports/TALOS-2024-2020
N/A
Hyperlink: https://talosintelligence.com/vulnerability_reports/TALOS-2024-2020
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2020
N/A
Hyperlink: https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2020
Resource: N/A
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:talos-cna@cisco.com
Published At:14 Jan, 2025 | 15:15
Updated At:03 Nov, 2025 | 22:17

Multiple OS command injection vulnerabilities exist in the internet.cgi set_add_routing() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists in the `gateway` POST parameter.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.19.1CRITICAL
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Primary3.17.2HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 9.1
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CPE Matches

WAVLINK Technology Ltd.
wavlink
>>wl-wn533a8_firmware>>m33a8.v5030.210505
cpe:2.3:o:wavlink:wl-wn533a8_firmware:m33a8.v5030.210505:*:*:*:*:*:*:*
WAVLINK Technology Ltd.
wavlink
>>wl-wn533a8>>-
cpe:2.3:h:wavlink:wl-wn533a8:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Secondarytalos-cna@cisco.com
CWE ID: CWE-77
Type: Secondary
Source: talos-cna@cisco.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://talosintelligence.com/vulnerability_reports/TALOS-2024-2020talos-cna@cisco.com
Exploit
Third Party Advisory
https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2020af854a3a-2127-422b-91ae-364da2661108
N/A
Hyperlink: https://talosintelligence.com/vulnerability_reports/TALOS-2024-2020
Source: talos-cna@cisco.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2020
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

438Records found

CVE-2023-32612
Matching Score-8
Assigner-JPCERT/CC
ShareView Details
Matching Score-8
Assigner-JPCERT/CC
CVSS Score-7.2||HIGH
EPSS-0.07% / 21.91%
||
7 Day CHG~0.00%
Published-30 Jun, 2023 | 04:01
Updated-27 Nov, 2024 | 15:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Client-side enforcement of server-side security issue exists in WL-WN531AX2 firmware versions prior to 2023526, which may allow an attacker with an administrative privilege to execute OS commands with the root privilege.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn531ax2wl-wn531ax2_firmwareWL-WN531AX2wl-wn531ax2
CWE ID-CWE-565
Reliance on Cookies without Validation and Integrity Checking
CVE-2024-39793
Matching Score-8
Assigner-Talos
ShareView Details
Matching Score-8
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-1.42% / 80.26%
||
7 Day CHG~0.00%
Published-14 Jan, 2025 | 14:20
Updated-03 Nov, 2025 | 22:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple external config control vulnerabilities exist in the nas.cgi set_nas() proftpd functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to permission bypass. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A configuration injection vulnerability exists in the `ftp_name` POST parameter.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-15
External Control of System or Configuration Setting
CVE-2024-39799
Matching Score-8
Assigner-Talos
ShareView Details
Matching Score-8
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-2.05% / 83.52%
||
7 Day CHG~0.00%
Published-14 Jan, 2025 | 14:21
Updated-03 Nov, 2025 | 22:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple external config control vulnerabilities exists in the openvpn.cgi openvpn_server_setup() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A configuration injection vulnerability exists in the `sel_open_interface` POST parameter.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-15
External Control of System or Configuration Setting
CVE-2024-39789
Matching Score-8
Assigner-Talos
ShareView Details
Matching Score-8
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-1.42% / 80.26%
||
7 Day CHG~0.00%
Published-14 Jan, 2025 | 14:20
Updated-03 Nov, 2025 | 22:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple external config control vulnerabilities exist in the nas.cgi set_ftp_cfg() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to permission bypass. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A configuration injection vulnerability exists within the `ftp_port` POST parameter.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-15
External Control of System or Configuration Setting
CVE-2024-21797
Matching Score-8
Assigner-Talos
ShareView Details
Matching Score-8
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-2.74% / 85.65%
||
7 Day CHG~0.00%
Published-14 Jan, 2025 | 14:21
Updated-21 Aug, 2025 | 18:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command execution vulnerability exists in the adm.cgi set_TR069() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2023-32622
Matching Score-8
Assigner-JPCERT/CC
ShareView Details
Matching Score-8
Assigner-JPCERT/CC
CVSS Score-7.2||HIGH
EPSS-0.08% / 22.71%
||
7 Day CHG~0.00%
Published-30 Jun, 2023 | 04:04
Updated-04 Dec, 2024 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper neutralization of special elements in WL-WN531AX2 firmware versions prior to 2023526 allows an attacker with an administrative privilege to execute OS commands with the root privilege.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn531ax2wl-wn531ax2_firmwareWL-WN531AX2wl-wn531ax2
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-10324
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.14% / 34.90%
||
7 Day CHG-0.23%
Published-12 Sep, 2025 | 19:32
Updated-02 Oct, 2025 | 19:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN578W2 firewall.cgi sub_401C5C command injection

A vulnerability was determined in Wavlink WL-WN578W2 221110. This affects the function sub_401C5C of the file firewall.cgi. This manipulation of the argument pingFrmWANFilterEnabled/blockSynFloodEnabled/blockPortScanEnabled/remoteManagementEnabled causes command injection. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn578w2_firmwarewl-wn578w2WL-WN578W2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10325
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 37.66%
||
7 Day CHG-0.26%
Published-12 Sep, 2025 | 20:02
Updated-02 Oct, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN578W2 login.cgi sub_401BA4 command injection

A vulnerability was identified in Wavlink WL-WN578W2 221110. This impacts the function sub_401340/sub_401BA4 of the file /cgi-bin/login.cgi. Such manipulation of the argument ipaddr leads to command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn578w2_firmwarewl-wn578w2WL-WN578W2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10962
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.09%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 18:32
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 SetName wireless.cgi sub_403198 command injection

A vulnerability was identified in Wavlink NU516U1 M16U1_V240425. This impacts the function sub_403198 of the file /cgi-bin/wireless.cgi of the component SetName Page. The manipulation of the argument mac_5g leads to command injection. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10323
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.14% / 34.90%
||
7 Day CHG-0.23%
Published-12 Sep, 2025 | 19:02
Updated-02 Oct, 2025 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN578W2 wizard_rep.shtml sub_409184 command injection

A vulnerability was found in Wavlink WL-WN578W2 221110. The impacted element is the function sub_409184 of the file /wizard_rep.shtml. The manipulation of the argument sel_EncrypTyp results in command injection. The attack may be performed from remote. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn578w2_firmwarewl-wn578w2WL-WN578W2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10960
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.09%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 18:02
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 DeleteMac wireless.cgi sub_402D1C command injection

A vulnerability was found in Wavlink NU516U1 M16U1_V240425. The impacted element is the function sub_402D1C of the file /cgi-bin/wireless.cgi of the component DeleteMac Page. Performing manipulation of the argument delete_list results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10963
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.09%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 19:02
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 firewall.cgi sub_4016F0 command injection

A security flaw has been discovered in Wavlink NU516U1 M16U1_V240425. Affected is the function sub_4016F0 of the file /cgi-bin/firewall.cgi. The manipulation of the argument del_flag results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10961
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.74% / 72.41%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 18:02
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 Delete_Mac_list wireless.cgi sub_4030C0 command injection

A vulnerability was determined in Wavlink NU516U1 M16U1_V240425. This affects the function sub_4030C0 of the file /cgi-bin/wireless.cgi of the component Delete_Mac_list Page. Executing manipulation of the argument delete_list can lead to command injection. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10964
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.09%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 19:32
Updated-07 Oct, 2025 | 20:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 firewall.cgi sub_401B30 command injection

A weakness has been identified in Wavlink NU516U1. Affected by this vulnerability is the function sub_401B30 of the file /cgi-bin/firewall.cgi. This manipulation of the argument remoteManagementEnabled causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10958
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.09%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 17:32
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 AddMac wireless.cgi sub_403010 command injection

A flaw has been found in Wavlink NU516U1 M16U1_V240425. Impacted is the function sub_403010 of the file /cgi-bin/wireless.cgi of the component AddMac Page. This manipulation of the argument macAddr causes command injection. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9149
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 53.14%
||
7 Day CHG~0.00%
Published-19 Aug, 2025 | 17:32
Updated-06 Oct, 2025 | 18:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-NU516U1 wireless.cgi sub_4032E4 command injection

A vulnerability was determined in Wavlink WL-NU516U1 M16U1_V240425. This impacts the function sub_4032E4 of the file /cgi-bin/wireless.cgi. This manipulation of the argument Guest_ssid causes command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1WL-NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-35518
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4.6||MEDIUM
EPSS-3.87% / 87.95%
||
7 Day CHG~0.00%
Published-09 Aug, 2022 | 19:56
Updated-20 Oct, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WAVLINK WN572HP3, WN533A8, WN530H4, WN535G3, WN531P3 nas.cgi has no filtering on parameters: User1Passwd and User1, which leads to command injection in page /nas_disk.shtml.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wn572hp3wn531p3wn531p3_firmwarewn535g3_firmwarewn533a8_firmwarewn530h4_firmwarewn572hp3_firmwarewn530h4wn533a8wn535g3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-34592
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-18.00% / 94.99%
||
7 Day CHG~0.00%
Published-07 Jul, 2022 | 00:00
Updated-03 Aug, 2024 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wavlink WL-WN575A3 RPT75A3.V4300.201217 was discovered to contain a command injection vulnerability via the function obtw. This vulnerability allows attackers to execute arbitrary commands via a crafted POST request.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wl-wn575a3_firmwarewl-wn575a3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-39761
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-10||CRITICAL
EPSS-2.40% / 84.75%
||
7 Day CHG~0.00%
Published-14 Jan, 2025 | 14:21
Updated-03 Nov, 2025 | 22:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple OS command injection vulnerabilities exist in the login.cgi set_sys_init() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary code execution. An attacker can make an unauthenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists within the `restart_week_value` POST parameter.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-39759
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-10||CRITICAL
EPSS-2.40% / 84.75%
||
7 Day CHG~0.00%
Published-14 Jan, 2025 | 14:21
Updated-03 Nov, 2025 | 22:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple OS command injection vulnerabilities exist in the login.cgi set_sys_init() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary code execution. An attacker can make an unauthenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists within the `restart_hour_value` POST parameter.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-38896
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-3.34% / 87.00%
||
7 Day CHG~0.00%
Published-24 Jun, 2024 | 00:00
Updated-06 Jun, 2025 | 17:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WAVLINK WN551K1 found a command injection vulnerability through the start_hour parameter of /cgi-bin/nightled.cgi.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wn551k1_firmwarewn551k1n/awn551k1_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-38894
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-1.55% / 81.09%
||
7 Day CHG~0.00%
Published-24 Jun, 2024 | 00:00
Updated-06 Jun, 2025 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WAVLINK WN551K1 found a command injection vulnerability through the IP parameter of /cgi-bin/touchlist_sync.cgi.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wn551k1_firmwarewn551k1n/awn551k1_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-48705
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-9.10% / 92.47%
||
7 Day CHG-1.21%
Published-02 Sep, 2025 | 00:00
Updated-04 Sep, 2025 | 17:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wavlink AC1200 with firmware versions M32A3_V1410_230602 and M32A3_V1410_240222 are vulnerable to a post-authentication command injection while resetting the password. This vulnerability is specifically found within the "set_sys_adm" function of the "adm.cgi" binary, and is due to improper santization of the user provided "newpass" field

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wl-wn531p3wl-wn531p3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-34166
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-10||CRITICAL
EPSS-4.68% / 89.08%
||
7 Day CHG~0.00%
Published-14 Jan, 2025 | 14:21
Updated-21 Aug, 2025 | 18:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An os command injection vulnerability exists in the touchlist_sync.cgi touchlistsync() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted set of HTTP requests can lead to arbitrary code execution. An attacker can send an HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-50756
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.12% / 77.86%
||
7 Day CHG+0.14%
Published-14 Jul, 2025 | 00:00
Updated-03 Oct, 2025 | 00:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wavlink WN535K3 20191010 was found to contain a command injection vulnerability in the set_sys_adm function via the newpass parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wn535k3wn535k3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-50757
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-6.39% / 90.80%
||
7 Day CHG+0.96%
Published-02 Sep, 2025 | 00:00
Updated-04 Sep, 2025 | 17:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wavlink WN535K3 20191010 was found to contain a command injection vulnerability in the set_sys_adm function via the username parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wl-wn535k3_firmwarewl-wn535k3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-50755
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-6.39% / 90.80%
||
7 Day CHG+0.96%
Published-02 Sep, 2025 | 00:00
Updated-04 Sep, 2025 | 17:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wavlink WN535K3 20191010 was found to contain a command injection vulnerability in the set_sys_cmd function via the command parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wl-wn535k3_firmwarewl-wn535k3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-38861
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.46% / 80.54%
||
7 Day CHG~0.00%
Published-15 Aug, 2023 | 00:00
Updated-09 Oct, 2024 | 13:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in Wavlink WL_WNJ575A3 v.R75A3_V1410_220513 allows a remote attacker to execute arbitrary code via username parameter of the set_sys_adm function in adm.cgi.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wl-wn575a3_firmwarewl-wn575a3n/awl_wnj575a3
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-39760
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-10||CRITICAL
EPSS-2.40% / 84.75%
||
7 Day CHG~0.00%
Published-14 Jan, 2025 | 14:21
Updated-03 Nov, 2025 | 22:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple OS command injection vulnerabilities exist in the login.cgi set_sys_init() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary code execution. An attacker can make an unauthenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists within the `restart_min_value` POST parameter.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-13117
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-93.94% / 99.88%
||
7 Day CHG-0.10%
Published-09 Feb, 2021 | 18:53
Updated-19 Aug, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wavlink WN575A4, WN579X3, and WN530G3A devices through 2020-05-15 allow unauthenticated remote users to inject commands via the key parameter in a login request.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wn575a4_firmwarewn575a4wn579x3wn579x3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44868
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.18% / 84.01%
||
7 Day CHG~0.00%
Published-02 May, 2025 | 00:00
Updated-13 Jun, 2025 | 13:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wavlink WL-WN530H4 20220801 was found to contain a command injection vulnerability in the ping_test function of the adm.cgi via the pingIp parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wl-wn530h4wl-wn530h4_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10358
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.18% / 39.65%
||
7 Day CHG-0.33%
Published-13 Sep, 2025 | 08:02
Updated-02 Oct, 2025 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN578W2 wireless.cgi sub_404850 os command injection

A security vulnerability has been detected in Wavlink WL-WN578W2 221110. This affects the function sub_404850 of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn578w2_firmwarewl-wn578w2WL-WN578W2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-10359
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.18% / 39.65%
||
7 Day CHG-0.33%
Published-13 Sep, 2025 | 13:02
Updated-02 Oct, 2025 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN578W2 wireless.cgi sub_404DBC os command injection

A vulnerability was detected in Wavlink WL-WN578W2 221110. This impacts the function sub_404DBC of the file /cgi-bin/wireless.cgi. The manipulation of the argument macAddr results in os command injection. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn578w2_firmwarewl-wn578w2WL-WN578W2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-10959
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.09%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 17:32
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 firewall.cgi sub_401778 command injection

A vulnerability has been found in Wavlink NU516U1 M16U1_V240425. The affected element is the function sub_401778 of the file /cgi-bin/firewall.cgi. Such manipulation of the argument dmz_flag leads to command injection. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11335
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.17% / 38.09%
||
7 Day CHG~0.00%
Published-06 Oct, 2025 | 12:32
Updated-19 Nov, 2025 | 21:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7100G C1 jhttpd msp_info.htm sub_46409C command injection

A weakness has been identified in D-Link DI-7100G C1 up to 20250928. Affected by this vulnerability is the function sub_46409C of the file /msp_info.htm?flag=qos of the component jhttpd. This manipulation of the argument iface causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7100g_c1_firmwaredi-7100g_c1DI-7100G C1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11331
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.27% / 49.74%
||
7 Day CHG~0.00%
Published-06 Oct, 2025 | 10:02
Updated-07 Oct, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
IdeaCMS Website Name Config.php command injection

A vulnerability was found in IdeaCMS up to 1.8. The impacted element is an unknown function of the file app/common/logic/admin/Config.php of the component Website Name Handler. Performing manipulation of the argument 网站名称 results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-ideacmsn/a
Product-ideacmsIdeaCMS
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2210
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.16% / 37.15%
||
7 Day CHG~0.00%
Published-09 Feb, 2026 | 02:02
Updated-11 Feb, 2026 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_filtering sub_4211C8 os command injection

A vulnerability has been found in D-Link DIR-823X 250416. This affects the function sub_4211C8 of the file /goform/set_filtering. Such manipulation leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2143
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.21% / 43.21%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 08:32
Updated-10 Feb, 2026 | 21:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X DDNS Service set_ddns os command injection

A security vulnerability has been detected in D-Link DIR-823X 250416. This issue affects some unknown processing of the file /goform/set_ddns of the component DDNS Service. The manipulation of the argument ddnsType/ddnsDomainName/ddnsUserName/ddnsPwd leads to os command injection. The attack is possible to be carried out remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2182
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.32% / 54.72%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 20:02
Updated-10 Feb, 2026 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
UTT 进取 521G setSysAdm doSystem command injection

A weakness has been identified in UTT 进取 521G 3.1.1-190816. Affected by this issue is the function doSystem of the file /goform/setSysAdm. Executing a manipulation of the argument passwd1 can lead to command injection. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-uttUTT
Product-521g_firmware521g进取 521G
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2260
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.19% / 41.12%
||
7 Day CHG~0.00%
Published-10 Feb, 2026 | 03:02
Updated-12 Feb, 2026 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-931L setSysAdmin os command injection

A vulnerability was found in D-Link DCS-931L up to 1.13.0. This affects an unknown part of the file /goform/setSysAdmin. The manipulation of the argument AdminID results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-931ldcs-931l_firmwareDCS-931L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2163
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.14% / 34.71%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 16:32
Updated-11 Feb, 2026 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-600 ssdp.cgi command injection

A vulnerability was identified in D-Link DIR-600 up to 2.15WWb02. This vulnerability affects unknown code of the file ssdp.cgi. Such manipulation of the argument HTTP_ST/REMOTE_ADDR/REMOTE_PORT/SERVER_ID leads to command injection. The attack may be launched remotely. The exploit is publicly available and might be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-600_firmwaredir-600DIR-600
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2120
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.21% / 43.21%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 00:32
Updated-11 Feb, 2026 | 18:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X Configuration Parameter set_server_settings os command injection

A vulnerability was identified in D-Link DIR-823X 250416. This affects an unknown function of the file /goform/set_server_settings of the component Configuration Parameter Handler. The manipulation of the argument terminal_addr/server_ip/server_port leads to os command injection. The attack may be initiated remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2227
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.09% / 24.98%
||
7 Day CHG~0.00%
Published-09 Feb, 2026 | 10:02
Updated-10 Feb, 2026 | 13:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-931L setSystemAdmin doSystem command injection

A vulnerability was found in D-Link DCS-931L up to 1.13.0. Impacted is the function doSystem of the file /setSystemAdmin. Performing a manipulation of the argument AdminID results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-931ldcs-931l_firmwareDCS-931L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2157
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.21% / 43.21%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 15:02
Updated-11 Feb, 2026 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_static_route_table sub_4175CC os command injection

A security vulnerability has been detected in D-Link DIR-823X 250416. This affects the function sub_4175CC of the file /goform/set_static_route_table. Such manipulation of the argument interface/destip/netmask/gateway/metric leads to os command injection. The attack may be performed from remote. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2188
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.28% / 51.30%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 21:32
Updated-10 Feb, 2026 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
UTT 进取 521G formPdbUpConfig sub_446B18 os command injection

A vulnerability was determined in UTT 进取 521G 3.1.1-190816. The impacted element is the function sub_446B18 of the file /goform/formPdbUpConfig. Executing a manipulation of the argument policyNames can lead to os command injection. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-uttUTT
Product-521g_firmware521g进取 521G
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-22601
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.6||HIGH
EPSS-0.08% / 23.50%
||
7 Day CHG+0.01%
Published-10 Jan, 2026 | 01:06
Updated-14 Jan, 2026 | 22:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
OpenProject is Vulnerable to Code Execution in E-Mail function

OpenProject is an open-source, web-based project management software. For OpenProject version 16.6.1 and below, a registered administrator can execute arbitrary command by configuring sendmail binary path and sending a test email. This issue has been patched in version 16.6.2.

Action-Not Available
Vendor-openprojectopf
Product-openprojectopenproject
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2155
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.18% / 39.32%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 14:02
Updated-11 Feb, 2026 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X Configuration set_dmz sub_4208A0 os command injection

A security flaw has been discovered in D-Link DIR-823X 250416. The affected element is the function sub_4208A0 of the file /goform/set_dmz of the component Configuration Handler. The manipulation of the argument dmz_host/dmz_enable results in os command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2152
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-1.21% / 78.68%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 12:32
Updated-11 Feb, 2026 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-615 Web Configuration adv_routing.php os command injection

A vulnerability was found in D-Link DIR-615 4.10. This vulnerability affects unknown code of the file adv_routing.php of the component Web Configuration Interface. Performing a manipulation of the argument dest_ip/ submask/ gw results in os command injection. The attack may be initiated remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-615_firmwaredir-615DIR-615
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2129
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.21% / 43.21%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 01:32
Updated-11 Feb, 2026 | 18:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_ac_status os command injection

A vulnerability was found in D-Link DIR-823X 250416. Affected by this issue is some unknown functionality of the file /goform/set_ac_status. Performing a manipulation of the argument ac_ipaddr/ac_ipstatus/ap_randtime results in os command injection. The attack may be initiated remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2142
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.21% / 43.21%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 08:02
Updated-10 Feb, 2026 | 21:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_qos sub_420688 os command injection

A weakness has been identified in D-Link DIR-823X 250416. This vulnerability affects the function sub_420688 of the file /goform/set_qos. Executing a manipulation can lead to os command injection. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 8
  • 9
  • Next
Details not found