A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover and unauthorized access to the system when an attacker conducts brute-force attacks against the login form.
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure of restricted web page, modification of web page and denial of service when specific web pages are modified and restricted functions are invoked.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report.
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.
A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.
A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module.
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to get limited knowledge of javascript code when crafted malicious parameters are submitted to the charging station web server.
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.
An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses in a way that exposes security-relevant information about the state of the product, such as whether a particular operation was successful or not.
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products.
Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet.
An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained.
The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data.
An information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system response to error provides more information than should be available to an unauthenticated user.
Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.
containerd is a container runtime available as a daemon for Linux and Windows. A bug was found in containerd prior to versions 1.6.1, 1.5.10, and 1.14.12 where containers launched through containerd’s CRI implementation on Linux with a specially-crafted image configuration could gain access to read-only copies of arbitrary files and directories on the host. This may bypass any policy-based enforcement on container setup (including a Kubernetes Pod Security Policy) and expose potentially sensitive information. Kubernetes and crictl can both be configured to use containerd’s CRI implementation. This bug has been fixed in containerd 1.6.1, 1.5.10, and 1.4.12. Users should update to these versions to resolve the issue.
An information disclosure vulnerability in ISPmanager v6.98.0 allows attackers to access sensitive details of the root user's session via an arbitrary command (ISP6-1779).
Directus is a real-time API and App dashboard for managing SQL database content. When relying on SSO providers in combination with local authentication it can be possible to enumerate existing SSO users in the instance. This is possible because if an email address exists in Directus and belongs to a known SSO provider then it will throw a "helpful" error that the user belongs to another provider. This vulnerability is fixed in 10.13.0.
A flaw was found in Keylime before 6.3.0. The logic in the Keylime agent for checking for a secure mount can be fooled by previously created unprivileged mounts allowing secrets to be leaked to other processes on the host.
Windows Remote Desktop Gateway (RD Gateway) Information Disclosure Vulnerability
Dorsett Controls Central Server update server has potential information leaks with an unprotected file that contains passwords and API keys.
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Olive Themes Olive One Click Demo Import allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects Olive One Click Demo Import: from n/a through 1.1.2.
Shenzhen Guoxin Synthesis image system before 8.3.0 allows unauthorized user information retrieval via the queryUser API.
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Dylan James Zephyr Project Manager.This issue affects Zephyr Project Manager: from n/a through 3.3.99.
FreshRSS is a free, self-hostable RSS aggregator. User configuration files can be accessed by a remote user. In addition to user preferences, such configurations contain hashed passwords (brypt with cost 9, salted) of FreshRSS Web interface. If the API is used, the configuration might contain a hashed password (brypt with cost 9, salted) of the GReader API, and a hashed password (MD5 salted) of the Fever API. Users should update to version 1.20.2 or edge. Users unable to upgrade can apply the patch manually or delete the file `./FreshRSS/p/ext.php`.
In Keylime before 6.3.0, current keylime installer installs the keylime.conf file, which can contain sensitive data, as world-readable.
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in HitPay Payment Solutions Pte Ltd HitPay Payment Gateway for WooCommerce allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects HitPay Payment Gateway for WooCommerce: from n/a through 4.1.3.
XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. The office document viewer macro was allowing anyone to see any file content from the hosting server, provided that the office server was connected and depending on the permissions of the user running the servlet engine (e.g. tomcat) running XWiki. The same vulnerability also allowed to perform internal requests to resources from the hosting server. The problem has been patched in XWiki 13.10.11, 14.10.1, 14.4.8, 15.0-rc-1. Users are advised to upgrade. It might be possible to workaround this vulnerability by running XWiki in a sandbox with a user with very low privileges on the machine.
Sensitive information disclosure discovered in wpDiscuz WordPress plugin (versions <= 7.3.11).
The vulnerability discovered in WordPress Perfect Brands for WooCommerce plugin (versions <= 2.0.4) allows server information exposure.
BigBlueButton is an open source web conferencing system. Versions prior to 2.4-rc-6 are vulnerable to Insertion of Sensitive Information Into Sent Data. The moderators-only webcams lock setting is not enforced on the backend, which allows an attacker to subscribe to viewers' webcams, even when the lock setting is applied. (The required streamId was being sent to all users even with lock setting applied). This issue is fixed in version 2.4-rc-6. There are no workarounds.