IBM Spectrum Protect Plus 10.1.0 through 10.1.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174975.
QXIP SIPCAPTURE homer-app before 1.4.28 for HOMER 7.x has the same 167f0db2-f83e-4baa-9736-d56064a5b415 JWT secret key across different customers' installations.
IBM SiteProtector Appliance 3.1.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174142.
An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device.
Dairy Farm Shop Management System v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised.
Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory.
The Web Administrative Interface in Mobile Viewpoint Wireless Multiplex Terminal (WMT) Playout Server 20.2.8 and earlier has a default account with a password of "pokon."
A vulnerability in Cisco Virtual Wide Area Application Services (vWAAS) with Cisco Enterprise NFV Infrastructure Software (NFVIS)-bundled images for Cisco ENCS 5400-W Series and CSP 5000-W Series appliances could allow an unauthenticated, remote attacker to log into the NFVIS CLI of an affected device by using accounts that have a default, static password. The vulnerability exists because the affected software has user accounts with default, static passwords. An attacker with access to the NFVIS CLI of an affected device could exploit this vulnerability by logging into the CLI. A successful exploit could allow the attacker to access the NFVIS CLI with administrator privileges.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default root126 password for the root account.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default debug124 password for the debug account.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default panger123 password for the suma123 account for certain old firmware.
Barco wePresent WiPG-1600W firmware includes a hardcoded API account and password that is discoverable by inspecting the firmware image. A malicious actor could use this password to access authenticated, administrative functions in the API. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default blank password for the guest account.
By default, BMC PATROL Agent through 11.3.01 uses a static encryption key for encrypting/decrypting user credentials sent over the network to managed PATROL Agent services. If an attacker were able to capture this network traffic, they could decrypt these credentials and use them to execute code or escalate privileges on the network.
Use of Hard-coded Credentials vulnerability in FortiRecorder all versions below 2.7.4 may allow an unauthenticated attacker with knowledge of the aforementioned credentials and network access to FortiCameras to take control of those, provided they are managed by a FortiRecorder device.
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
IBM Security Identity Manager 7.0.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 171511.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
FreeSWITCH 1.6.10 through 1.10.1 has a default password in event_socket.conf.xml.
An issue was discovered in TitanHQ WebTitan before 5.18. It has a hidden support account (with a hard-coded password) in the web administration interface, with administrator privileges. Anybody can log in with this account.
Jalios JCMS 10 allows attackers to access any part of the website and the WebDAV server with administrative privileges via a backdoor account, by using any username and the hardcoded dev password.
An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A specially-crafted HTTP request can lead to unauthorized access. An attacker can send an HTTP request to trigger this vulnerability.
A hard-coded password vulnerability in the Fortinet FortiSIEM database component version 5.2.5 and below may allow attackers to access the device database via the use of static credentials.
A vulnerability in the web-based management interface of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. The vulnerability is due to improper session management on affected DCNM software. An attacker could exploit this vulnerability by sending a crafted HTTP request to the affected device. A successful exploit could allow the attacker to gain administrative access on the affected device.
An issue was discovered in GitLab Community and Enterprise Edition 12.0 through 12.1.4. It uses Hard-coded Credentials.
TELESTAR Bobs Rock Radio, Dabman D10, Dabman i30 Stereo, Imperial i110, Imperial i150, Imperial i200, Imperial i200-cd, Imperial i400, Imperial i450, Imperial i500-bt, and Imperial i600 TN81HH96-g102h-g102 devices have insufficient access control for the /set_dname, /mylogo, /LocalPlay, /irdevice.xml, /Sendkey, /setvol, /hotkeylist, /init, /playlogo.jpg, /stop, /exit, /back, and /playinfo commands.
CA Network Flow Analysis 9.x and 10.0.x have a default credential vulnerability that can allow a remote attacker to execute arbitrary commands and compromise system security.
An issue was discovered in Shinobi through ocean version 1. lib/auth.js has Incorrect Access Control. Valid API Keys are held in an internal JS Object. Therefore an attacker can use JS Proto Method names (such as constructor or hasOwnProperty) to convince the System that the supplied API Key exists in the underlying JS object, and consequently achieve complete access to User/Admin/Super API functions, as demonstrated by a /super/constructor/accounts/list URI.
Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1.
A clone version of an ELM327 OBD2 Bluetooth device has a hardcoded PIN, leading to arbitrary commands to an OBD-II bus of a vehicle.
A vulnerability was found in demozx gf_cms 1.0/1.0.1. It has been classified as critical. This affects the function init of the file internal/logic/auth/auth.go of the component JWT Authentication. The manipulation leads to hard-coded credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.2 is able to address this issue. The patch is named be702ada7cb6fdabc02689d90b38139c827458a5. It is recommended to upgrade the affected component.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled.
The express install, which is the suggested way to install Puppet Enterprise, gives the user a URL at the end of the install to set the admin password. If they do not use that URL, there is an overlooked default password for the admin user. This was resolved in Puppet Enterprise 2019.0.3 and 2018.1.9.
The Web-GUI on WAGO Series 750-88x (750-330, 750-352, 750-829, 750-831, 750-852, 750-880, 750-881, 750-882, 750-884, 750-885, 750-889) and Series 750-87x (750-830, 750-849, 750-871, 750-872, 750-873) devices has undocumented service access.
Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
ICS/StaticPages/AddTestUsers.aspx in Jenzabar JICS (aka Internet Campus Solution) before 2019-02-06 allows remote attackers to create an arbitrary number of accounts with a password of 1234.
A low privileged admin account with a weak default password of admin exists on the Foxconn FEMTO AP-FC4064-T AP_GT_B38_5.8.3lb15-W47 LTE Build 15. In addition, its web management page relies on the existence or values of cookies when performing security-critical operations. One can gain privileges by modifying cookies.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In other words, these devices use private-key values in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key files that are publicly available from the vendor web sites.
A vulnerability in Brocade Network Advisor Version Before 14.3.1 could allow an unauthenticated, remote attacker to log in to the JBoss Administration interface of an affected system using an undocumented user credentials and install additional JEE applications.
Certain NETGEAR devices are affected by a hardcoded password. This affects D3600 before 1.0.0.76 and D6000 before 1.0.0.76.
IBM Security Identity Governance and Intelligence 5.2 through 5.2.4.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153386.
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.
The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00
Deltek Vision 7.x before 7.6 permits the execution of any attacker supplied SQL statement through a custom RPC over HTTP protocol. The Vision system relies on the client binary to enforce security rules and integrity of SQL statements and other content being sent to the server. Client HTTP calls can be manipulated by one of several means to execute arbitrary SQL statements (similar to SQLi) or possibly have unspecified other impact via this custom protocol. To perform these attacks an authenticated session is first required. In some cases client calls are obfuscated by encryption, which can be bypassed due to hard-coded keys and an insecure key rotation protocol. Impacts may include remote code execution in some deployments; however, the vendor states that this cannot occur when the installation documentation is heeded.