A code injection vulnerability exists in Yonyou UFIDA NC v6.5 and prior due to the exposure of the BeanShell testing servlet (bsh.servlet.BshServlet) without proper access controls. The servlet allows unauthenticated remote attackers to execute arbitrary Java code via the bsh.script parameter. This can be exploited to run system commands and ultimately gain full control over the target server. The issue is rooted in a third-party JAR component bundled with the application, and the servlet is accessible without authentication on vulnerable installations. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC.
An authenticated multi-stage remote code execution vulnerability exists in Riverbed SteelCentral NetProfiler and NetExpress 10.8.7 virtual appliances. A SQL injection vulnerability in the '/api/common/1.0/login' endpoint can be exploited to create a new user account in the appliance database. This user can then trigger a command injection vulnerability in the '/index.php?page=licenses' endpoint to execute arbitrary commands. The attacker may escalate privileges to root by exploiting an insecure sudoers configuration that allows the 'mazu' user to execute arbitrary commands as root via SSH key extraction and command chaining. Successful exploitation allows full remote root access to the virtual appliance.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
A missing authentication vulnerability in the GFIAgent component of GFI Kerio Control 9.4.5 allows unauthenticated remote attackers to perform privileged operations. The GFIAgent service, responsible for integration with GFI AppManager, exposes HTTP services on ports 7995 and 7996 without proper authentication. The /proxy handler on port 7996 allows arbitrary forwarding to administrative endpoints when provided with an Appliance UUID, which itself can be retrieved from port 7995. This results in a complete authentication bypass, permitting access to sensitive administrative APIs.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.
AVideo versions prior to 20.1 with the ImageGallery plugin enabled is vulnerable to unauthenticated file upload and deletion. Plugin endpoints responsible for managing gallery images fail to enforce authentication checks and do not validate ownership, allowing unauthenticated attackers to upload or delete images associated with any image-based video.
An unauthenticated command injection vulnerability exists in stamparm/maltrail (Maltrail) versions <=0.54. A remote attacker can execute arbitrary operating system commands via the username parameter in a POST request to the /login endpoint. This occurs due to unsafe handling of user-supplied input passed to subprocess.check_output() in core/http.py, allowing injection of shell metacharacters. Exploitation does not require authentication and commands are executed with the privileges of the Maltrail process.
Traq versions 2.0 through 2.3 contain a remote code execution vulnerability in the admincp/common.php script. The flawed authorization logic fails to halt execution after a failed access check, allowing unauthenticated users to reach admin-only functionality. This can be exploited via plugins.php to inject and execute arbitrary PHP code.
HashiCorp Vault Enterprise 1.7.0 through 1.9.7, 1.10.4, and 1.11.0 clusters using Integrated Storage expose an unauthenticated API endpoint that could be abused to override the voter status of a node within a Vault HA cluster, introducing potential for future data loss or catastrophic failure. Fixed in Vault Enterprise 1.9.8, 1.10.5, and 1.11.1.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to factory reset the device via crafted HTTP requests.
The administrative web interface of mySCADA myPRO Manager can be accessed without authentication which could allow an unauthorized attacker to retrieve sensitive information and upload files without the associated password.
Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.
Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols' functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service.
JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.
Two path traversal vulnerabilities in the Network Installation Service (NIS) of Altium Enterprise Server allow an unauthenticated network attacker to write arbitrary files to any writable location on the server filesystem and to read package archive files from the server. No authentication, session, or credentials are required. Because content-controlled files can be written to web-accessible directories, or used to overwrite application binaries or configuration files, exploitation can be escalated to remote code execution in the context of the service account, and can disclose deployment package contents. Altium 365 cloud deployments are not affected, as the Network Installation Service is not part of the cloud offering.
An access control issue in Zammad v5.0.3 allows attackers to write entries to the CTI caller log without authentication. This vulnerability can allow attackers to execute phishing attacks or cause a Denial of Service (DoS).
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files.
Server Version Disclosure.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 .
Resource Lacking AuthN.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 .
An authentication bypass vulnerability exists in the WordPress Pie Register plugin ≤ 3.7.1.4 that allows unauthenticated attackers to impersonate arbitrary users by submitting a crafted POST request to the login endpoint. By setting social_site=true and manipulating the user_id_social_site parameter, an attacker can generate a valid WordPress session cookie for any user ID, including administrators. Once authenticated, the attacker may exploit plugin upload functionality to install a malicious plugin containing arbitrary PHP code, resulting in remote code execution on the underlying server.
TadTools special page is vulnerable to authorization bypass, thus remote attackers can use the specific parameter to delete arbitrary files in the system without logging in.
AMI BMC contains a vulnerability in the IPMI handler, where an unauthenticated host is allowed to write to a host SPI flash, bypassing secure boot protections. An exploitation of this vulnerability may lead to a loss of integrity or denial of service.
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC-F Series CPU modules, MELSEC iQ-F Series, MELSEC iQ-R series CPU modules, MELSEC iQ-R series, MELSEC iQ-L series, MELSEC Q series, MELSEC-L series, Mitsubishi Electric CNC M800V/M80V series, Mitsubishi Electric CNC M800/M80/E80 series and Mitsubishi Electric CNC M700V/M70V/E70 series allows a remote unauthenticated attacker to execute arbitrary commands by sending specific packets to the affected products. This could lead to disclose or tamper with information by reading or writing control programs, or cause a denial-of-service (DoS) condition on the products by resetting the memory contents of the products to factory settings or resetting the products remotely.
An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.
An issue has recently been discovered in Arista EOS where certain gNOI APIs incorrectly skip authorization and authentication which could potentially allow a factory reset of the device.
An exploitable denial-of-service vulnerability exists in the iocheckd service "I/O-Check" functionality of WAGO PFC 200 Firmware versions 03.01.07(13) and 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A single packet can cause a denial of service and weaken credentials resulting in the default documented credentials being applied to the device. An attacker can send an unauthenticated packet to trigger this vulnerability.
Power Line Communications PLC4TRUCKS J2497 trailer brake controllers implement diagnostic functions which can be invoked by replaying J2497 messages. There is no authentication or authorization for these functions.