FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the byruleEditName parameter in the web_acl_mgmt_Rules_Edit_postcontains function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the stp_conf_name parameter in the web_stp_globalSetting_post function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the web_sys_infoContact_post function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the theauthName parameter in the web_aaa_loginAuthlistEdit function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the radDftParamKey parameter in the web_radiusSrv_dftParam_post function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the bytftp_srvip parameter in the web_tool_upgradeManager_post function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the tacIp parameter in the web_tacplus_serverEdit_post function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the host_ip parameter in the web_snmp_v3host_add_post function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the remote_ip parameter in the web_snmpv3_remote_engineId_add_post function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the ruleNamekey parameter in the web_acl_mgmt_Rules_Apply_post function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the bindEditMACName parameter in the web_acl_bindEdit_post function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the radIpkey parameter in the web_radiusSrv_post function.
The firmware of the PLANET Technology Corp NVR-915 and NVR-1615 before 2020-10-28 embeds default credentials for root access via telnet. By exposing telnet on the Internet, remote root access on the device is possible. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
An issue in Planet Technologies WDRT-1800AX v1.01-CP21 allows attackers to bypass authentication and escalate privileges to root via manipulation of the LoginStatus cookie.
Certain switch models from PLANET Technology lack proper access control in firmware upload and download functionality, allowing unauthenticated remote attackers to download and upload firmware and system configurations, ultimately gaining full control of the devices.
Certain switch models from PLANET Technology have a Hard-coded community string in the SNMPv1 service, allowing unauthorized remote attackers to use this community string to access the SNMPv1 service with read-write privileges.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the ownekey parameter in the web_rmon_alarm_post_rmon_alarm function.
FW-WGS-804HPT v1.305b241111 was discovered to contain a stack overflow via the ipv4Aclkey parameter in the web_acl_ipv4BasedAceAdd function.
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
A stack-based buffer overflow vulnerability exists in the confsrv set_mf_rule functionality of TCL LinkHub Mesh Wifi MS1G_00_01.00_14. A specially-crafted network packet can lead to stack-based buffer overflow. An attacker can send a malicious packet to trigger this vulnerability.This vulnerability leverages the ethAddr field within the protobuf message to cause a buffer overflow.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Sonos One Speaker prior to 3.4.1 (S2 systems) and 11.2.13 build 57923290 (S1 systems). Authentication is not required to exploit this vulnerability. The specific flaw exists within the ALAC audio codec. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-15798.
TOTOLINK A3700R V9.1.2u.6165_20211012 was discovered to contain a stack overflow via ssid in the function setWiFiEasyCfg.
A stack-based buffer overflow vulnerability exists in the confsrv set_mf_rule functionality of TCL LinkHub Mesh Wifi MS1G_00_01.00_14. A specially-crafted network packet can lead to stack-based buffer overflow. An attacker can send a malicious packet to trigger this vulnerability.This vulnerability leverages the name field within the protobuf message to cause a buffer overflow.
TOTOLINK LR350 V9.3.5u.6369_B20220309 was discovered to contain a stack overflow via the http_host parameter in the function loginAuth.
A stack-based buffer overflow in Fortinet FortiAnalyzer versions 7.4.0 through 7.4.3, 7.2.0 through 7.2.5, 7.0.0 through 7.0.12, 6.4.0 through 6.4.14, FortiManager versions 7.4.0 through 7.4.3, 7.2.0 through 7.2.5, 7.0.0 through 7.0.12, 6.4.0 through 6.4.14, FortiManager Cloud versions 7.4.1 through 7.4.3, 7.2.1 through 7.2.5, 7.0.1 through 7.0.11, 6.4.1 through 6.4.7, FortiAnalyzer Cloud versions 7.4.1 through 7.4.3, 7.2.1 through 7.2.5, 7.0.1 through 7.0.11, 6.4.1 through 6.4.7 allows attacker to execute unauthorized code or commands via specially crafted packets.
An issue was discovered on Supermicro BMC firmware in select X11, X12, H12, B12, X13, H13, and B13 motherboards (and CMM6 modules). An unauthenticated user can post crafted data to the interface that triggers a stack buffer overflow, and may lead to arbitrary remote code execution on a BMC.
A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Affected by this vulnerability is the function fromDhcpListClient. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-230077 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A stack-based buffer overflow vulnerability exists in the touchlist_sync.cgi touchlistsync() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary code execution. An attacker can send an HTTP request to trigger this vulnerability.
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/RouteStatic.
My Cloud OS 5 was vulnerable to a pre-authenticated stack overflow vulnerability on the FTP service that could be exploited by unauthenticated attackers on the network. Addressed the vulnerability by adding defenses against stack overflow issues.
An SEH-based buffer overflow in the BPQ32 HTTP Server in BPQ32 6.0.24.1 allows remote attackers with access to the Web Terminal to achieve remote code execution via an HTTP POST /TermInput request.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Netatalk. Authentication is not required to exploit this vulnerability. The specific flaw exists within the copyapplfile function. When parsing the len element, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-15869.
A stack-based buffer overflow vulnerability exists in the confsrv confctl_set_app_language functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to stack-based buffer overflow. An attacker can send a malicious packet to trigger this vulnerability.
Shenzhen Libituo Technology Co., Ltd LBT-T300-T400 v3.2 was discovered to contain a stack overflow via the apn_name_3g parameter in the config_3g_para function.
A vulnerability, which was classified as critical, has been found in H3C R160 V1004004. Affected by this issue is some unknown functionality of the file /goForm/aspForm. The manipulation of the argument go leads to stack-based buffer overflow. The exploit has been disclosed to the public and may be used. VDB-228890 is the identifier assigned to this vulnerability.
TOTOLINK CP450 v4.1.0cu.747_B20191224 was discovered to contain a stack buffer overflow vulnerability in the SetPortForwardRules function.
Fuji Electric Monitouch V-SFT is vulnerable to a stack-based buffer overflow, which could allow an attacker to execute arbitrary code.
TOTOLINK CP450 v4.1.0cu.747_B20191224 was discovered to contain a stack buffer overflow vulnerability in the setIpPortFilterRules function.
A Stack-based buffer overflow vulnerability in the SonicOS via HTTP request allows a remote unauthenticated attacker to cause Denial of Service (DoS) or potentially results in code execution in the firewall.
A stack-based buffer overflow vulnerability exists in the OpenPLC Runtime EtherNet/IP parser functionality of OpenPLC _v3 b4702061dc14d1024856f71b4543298d77007b88. A specially crafted EtherNet/IP request can lead to remote code execution. An attacker can send a series of EtherNet/IP requests to trigger this vulnerability.
Stack-based buffer overflow vulnerabilities affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an unauthenticated remote attacker to execute arbitrary code.
NVIDIA DGX H100 baseboard management controller (BMC) contains a vulnerability in a web server plugin, where an unauthenticated attacker may cause a stack overflow by sending a specially crafted network packet. A successful exploit of this vulnerability may lead to arbitrary code execution, denial of service, information disclosure, and data tampering.
D-Link N300 WI-FI Router DIR-605L v2.13B01 was discovered to contain a stack overflow via the curTime parameter at /goform/formSetACLFilter.
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formQuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/addressNat.
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/addWifiMacFilter.
TOTOLINK A3700R V9.1.2u.6165_20211012 was discovered to contain a stack overflow via ssid in the function setWiFiBasicCfg