Improper Input Validation vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Command Injection.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.0; NEXUS Series: from 3.0;0 before 3.07.0; MATRIX Series: from 3.0;0 before 3.07.1.
A vulnerability has been found in TRENDnet TEW-811DRU 1.0.10.0 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-220018 is the identifier assigned to this vulnerability.
Baicells EG7035-M11 devices with firmware through BCE-ODU-1.0.8 are vulnerable to improper code exploitation via HTTP GET command injections. Commands are executed using pre-login execution and executed with root permissions. The following methods have been tested and validated by a 3rd party analyst and have been confirmed exploitable special thanks to Lionel Musonza for the discovery.
A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152.
Command Injection in GitHub repository thorsten/phpmyfaq prior to 3.1.11.
A vulnerability was found in TRENDnet TEW-652BRP 3.04b01. It has been classified as critical. Affected is an unknown function of the file ping.ccp of the component Web Interface. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220020.
All versions of yongyou PLM are affected by a command injection issue. UFIDA PLM (Product Life Cycle Management) is a strategic management method. It applies a series of enterprise application systems to support the entire process from conceptual design to the end of product life, and the collaborative creation, distribution, application and management of product information across organizations. Yonyou PLM uses jboss by default, and you can access the management control background without authorization An attacker can use this vulnerability to gain server permissions.
ColdFusion 2018- update 4 and earlier and ColdFusion 2016- update 11 and earlier have a Command Injection via Vulnerable component vulnerability. Successful exploitation could lead to Arbitrary code execution in the context of the current user.
This vulnerability allows a Backup or Tape Operator to perform remote code execution (RCE) as root by creating a malicious backup configuration file.
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection').
A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution.
Edgecore ECS2020 Firmware 1.0.0.0 devices allow Unauthenticated Command Injection via the command1 HTTP header to the /EXCU_SHELL URI.
A remote code execution vulnerability in development mode Rails <5.2.2.1, <6.0.0.beta3 can allow an attacker to guess the automatically generated development mode secret token. This secret token can be used in combination with other Rails internals to escalate to a remote code execution exploit.
There is a system command injection vulnerability in BiSheng-WNM FW 3.0.0.325. Successful exploitation could allow attackers to gain higher privileges.
A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Netdata is an open source option for real-time infrastructure monitoring and troubleshooting. An attacker with the ability to establish a streaming connection can execute arbitrary commands on the targeted Netdata agent. When an alert is triggered, the function `health_alarm_execute` is called. This function performs different checks and then enqueues a command by calling `spawn_enq_cmd`. This command is populated with several arguments that are not sanitized. One of them is the `registry_hostname` of the node for which the alert is raised. By providing a specially crafted `registry_hostname` as part of the health data that is streamed to a Netdata (parent) agent, an attacker can execute arbitrary commands at the remote host as a side-effect of the raised alert. Note that the commands are executed as the user running the Netdata Agent. This user is usually named `netdata`. The ability to run arbitrary commands may allow an attacker to escalate privileges by escalating other vulnerabilities in the system, as that user. The problem has been fixed in: Netdata agent v1.37 (stable) and Netdata agent v1.36.0-409 (nightly). As a workaround, streaming is not enabled by default. If you have previously enabled this, it can be disabled. Limiting access to the port on the recipient Agent to trusted child connections may mitigate the impact of this vulnerability.
There is a system command injection vulnerability in BiSheng-WNM FW 3.0.0.325. A Huawei printer has a system command injection vulnerability. Successful exploitation could lead to remote code execution.
Nanoleaf Desktop App before v1.3.1 was discovered to contain a command injection vulnerability which is exploited via a crafted HTTP request.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Apache Software Foundation Apache Airflow Hive Provider.This issue affects Apache Airflow Hive Provider: before 5.0.0.
A command injection vulnerability has been identified in Atos Unify OpenScape 4000 Assistant and Unify OpenScape 4000 Manager (8 before R2.22.18, 10 before 0.28.13, and 10 R1 before R1.34.4) that may allow an unauthenticated attacker to upload arbitrary files and achieve administrative access to the system.
Possible Command injection Vulnerability in iManager has been discovered in OpenText™ iManager 3.2.4.0000.
xterm before 375 allows code execution via font ops, e.g., because an OSC 50 response may have Ctrl-g and therefore lead to command execution within the vi line-editing mode of Zsh. NOTE: font ops are not allowed in the xterm default configurations of some Linux distributions.
An LDAP injection vulnerability in the login page of Gladinet CentreStack v13.12.9934.54690 allows attackers to access sensitive data or execute arbitrary commands via a crafted payload injected into the username field.
Alarm instance management has command injection when there is a specific command configured. It is only for logged-in users. We recommend you upgrade to version 2.0.6 or higher
In Versa Director, the command injection is an attack in which the goal is execution of arbitrary commands on the host operating system via a vulnerable application. Command injection attacks are possible when an application passes unsafe user supplied data (forms, cookies, HTTP headers etc.) to a system shell. In this attack, the attacker-supplied operating system commands are usually executed with the privileges of the vulnerable application. Command injection attacks are possible largely due to insufficient input validation.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.14, EX6100v2 before 1.0.1.98, EX6150v2 before 1.0.1.98, EX6250 before 1.0.0.132, EX6400 before 1.0.2.158, EX6400v2 before 1.0.0.132, EX6410 before 1.0.0.132, EX6420 before 1.0.0.132, EX7300 before 1.0.2.158, EX7300v2 before 1.0.0.132, EX7320 before 1.0.0.132, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, R7800 before 1.0.2.78, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.6.2.4, RBS50Y before 2.6.1.40, RBW30 before 2.6.2.2, and XR500 before 2.3.2.114.
A command injection vulnerability exists in Jitsi before commit 8aa7be58522f4264078d54752aae5483bfd854b2 when launching browsers on Windows which could allow an attacker to insert an arbitrary URL which opens up the opportunity to remote execution.
A vulnerability has been found in Teledyne FLIR AX8 up to 1.46.16. Affected by this issue is some unknown functionality of the file palette.php of the component Web Service Handler. The manipulation of the argument palette leads to command injection. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.49.16 can resolve this issue. Upgrading the affected component is advised. The vendor points out: "FLIR AX8 internal web site has been refactored to be able to handle the reported vulnerabilities."
There is a command injection vulnerability using environment variables in Bitbucket Server and Data Center. An attacker with permission to control their username can exploit this issue to execute arbitrary code on the system. This vulnerability can be unauthenticated if the Bitbucket Server and Data Center instance has enabled “Allow public signup”.
IP-COM EW9 V15.11.0.14(9732) was discovered to contain a command injection vulnerability in the formSetDebugCfg function.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7800 before 1.0.1.56, R7800 before 1.0.2.68, R8900 before 1.0.4.26, and R9000 before 1.0.4.26.
D-Link DIR-823G v1.0.2 was found to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via a crafted packet.
IBM InfoSphere DataStage 11.7 is vulnerable to a command injection vulnerability due to improper neutralization of special elements. IBM X-Force ID: 236687.
SolarView Compact 6.00 was discovered to contain a command injection vulnerability via network_test.php
QVidium Technologies Amino A140 (prior to firmware version 1.0.0-283) was discovered to contain a command injection vulnerability.
Tenda i9 v1.0.0.8(3828) was discovered to contain a command injection vulnerability via the FormexeCommand function.
A Command injection vulnerability in RaspAP 2.8.0 thru 2.8.7 allows unauthenticated attackers to execute arbitrary commands via the cfg_id parameter in /ajax/openvpn/activate_ovpncfg.php and /ajax/openvpn/del_ovpncfg.php.
Microchip Technology (Microsemi) SyncServer S650 was discovered to contain a command injection vulnerability.
There is a command injection vulnerability in ZTE MF286R, Due to insufficient validation of the input parameters, an attacker could use the vulnerability to execute arbitrary commands.
Hytec Inter HWL-2511-SS v1.05 and below was discovered to contain a command injection vulnerability via the component /www/cgi-bin/popen.cgi.
A command injection vulnerability in the CLI (Command Line Interface) implementation of Hytec Inter HWL-2511-SS v1.05 and below allows attackers to execute arbitrary commands with root privileges.
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Some web scripts in the web interface allowed injection and execution of arbitrary unintended commands on the web server, a different vulnerability than CVE-2019-16364.
WAVLINK WN572HP3, WN533A8, WN530H4, WN535G3, WN531P3 nas.cgi has no filtering on parameters: User1Passwd and User1, which leads to command injection in page /nas_disk.shtml.
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Arbitrary commands could be injected (using Python scripts) via the AprolCluster script that is invoked via sudo and thus executes with root privileges, a different vulnerability than CVE-2019-16364.
D-Link DIR810LA1_FW102B22 was discovered to contain a command injection vulnerability via the Ping_addr function.
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges.
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.15), Teamcenter V13.0 (All versions < V13.0.0.10), Teamcenter V13.1 (All versions < V13.1.0.10), Teamcenter V13.2 (All versions < V13.2.0.9), Teamcenter V13.3 (All versions < V13.3.0.5), Teamcenter V14.0 (All versions < V14.0.0.2). File Server Cache service in Teamcenter consist of a functionality that is vulnerable to command injection. This could potentially allow an attacker to perform remote code execution.
In Boa, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20220026; Issue ID: OSBNB00144124.
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. The AprolLoader could be used to inject and execute arbitrary unintended commands via an unspecified attack scenario, a different vulnerability than CVE-2019-16364.