DrayTek Vigor3900 v1.5.1.6 was discovered to contain an authenticated command injection vulnerability via the name parameter in the run_command function.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setUrlFilterRules. Authenticated Attackers can send malicious packet to execute arbitrary commands.
Artica Pandora FMS 7.44 allows remote command execution via the events feature.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setL2tpServerCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.
rConfig 3.9.4 and earlier allows authenticated code execution (of system commands) by sending a forged GET request to lib/ajaxHandlers/ajaxAddTemplate.php or lib/ajaxHandlers/ajaxEditTemplate.php.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
An OS command injection vulnerability exists in multiple D-Link routers—confirmed on DIR-300 rev A (v1.05) and DIR-615 rev D (v4.13)—via the authenticated tools_vct.xgi CGI endpoint. The web interface fails to properly sanitize user-supplied input in the pingIp parameter, allowing attackers with valid credentials to inject arbitrary shell commands. Exploitation enables full device compromise, including spawning a telnet daemon and establishing a root shell. The vulnerability is present in firmware versions that expose tools_vct.xgi and use the Mathopd/1.5p6 web server. No vendor patch is available, and affected models are end-of-life.
On SuperMicro X8STi-F motherboards with IPMI firmware 2.06 and BIOS 02.68, the Virtual Media feature allows OS Command Injection by authenticated attackers who can send HTTP requests to the IPMI IP address. This requires a POST to /rpc/setvmdrive.asp with shell metacharacters in ShareHost or ShareName. The attacker can achieve a persistent backdoor.
Certain TP-Link devices allow Command Injection. This affects NC260 1.5.2 build 200304 and NC450 1.5.3 build 200304.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
An issue was found in Apache Airflow versions 1.10.10 and below. A remote code/command injection vulnerability was discovered in one of the example DAGs shipped with Airflow which would allow any authenticated user to run arbitrary commands as the user running airflow worker/scheduler (depending on the executor in use). If you already have examples disabled by setting load_examples=False in the config then you are not vulnerable.
All versions up to V1.1.10P3T18 of ZTE ZXHN F670 product are impacted by command injection vulnerability. Due to insufficient parameter validation check, an authorized user can exploit this vulnerability to take control of user router system.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setWanIeCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.
A low privileged remote attacker can trigger the execution of arbitrary OS commands as root due to improper neutralization of special elements in the variable PROXY_HTTP_PORT in mGuard devices.
A low privileged remote attacker can trigger the execution of arbitrary OS commands as root due to improper neutralization of special elements in the variable EMAIL_NOTIFICATION.TO in mGuard devices.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setDmzCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.
Polycom HDX Video End Points before 3.0.4 and UC APL before 2.7.1.J allows remote authenticated users to execute arbitrary commands as demonstrated by a ; (semicolon) to the ping command feature.
Roxy-WI is a web interface for managing Haproxy, Nginx, Apache and Keepalived servers. An OS Command Injection vulnerability allows any authenticated user on the application to execute arbitrary code on the web application server via port scanning functionality. User-supplied input is used without validation when constructing and executing an OS command. User supplied JSON POST data is parsed and if "id" JSON key does not exist, JSON value supplied via "ip" JSON key is assigned to the "ip" variable. Later on, "ip" variable which can be controlled by the attacker is used when constructing the cmd and cmd1 strings without any extra validation. Then, server_mod.subprocess_execute function is called on both cmd1 and cmd2. When the definition of the server_mod.subprocess_execute() function is analyzed, it can be seen that subprocess.Popen() is called on the input parameter with shell=True which results in OS Command Injection. This issue has not yet been patched. Users are advised to contact the Roxy-WI to coordinate a fix.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
An exploitable command injection vulnerability exists in the web server functionality of Moxa EDR-810 V4.1 build 17030317. A specially crafted HTTP POST can cause a privilege escalation resulting in root shell. An attacker can inject OS commands into the openvpnServer0_tmp= parameter in the "/goform/net\_Web\_get_value" uri to trigger this vulnerability.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
IBM Spectrum Scale 4.2 and 5.0 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially-crafted request, an attacker could exploit this vulnerability to execute arbitrary commands on the system. IBM X-Force ID: 172093.
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
trixbox 2.8.0.4 has OS command injection via shell metacharacters in the lang parameter to /maint/modules/home/index.php.
N-Reporter and N-Cloud, products of the N-Partner, have an OS Command Injection vulnerability. Remote attackers with normal user privilege can execute arbitrary system commands by manipulating user inputs on a specific page.
Authenticated Semi-Blind Command Injection (via Parameter Injection) exists on Altus Nexto, Nexto Xpress, and Hadron Xtorm devices via the getlogs.cgi tcpdump feature. This affects Nexto NX3003 1.8.11.0, Nexto NX3004 1.8.11.0, Nexto NX3005 1.8.11.0, Nexto NX3010 1.8.3.0, Nexto NX3020 1.8.3.0, Nexto NX3030 1.8.3.0, Nexto NX5100 1.8.11.0, Nexto NX5101 1.8.11.0, Nexto NX5110 1.1.2.8, Nexto NX5210 1.1.2.8, Nexto Xpress XP300 1.8.11.0, Nexto Xpress XP315 1.8.11.0, Nexto Xpress XP325 1.8.11.0, Nexto Xpress XP340 1.8.11.0, and Hadron Xtorm HX3040 1.7.58.0.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in delBlacklist. Authenticated Attackers can send malicious packet to execute arbitrary commands.
A low privileged remote attacker can read and write files as root due to improper neutralization of special elements in the variable EMAIL_RELAY_PASSWORD in mGuard devices.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setAccessDeviceCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.
OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings.
IBM FileNet Content Manager 5.5.4, 5.5.6, and 5.5.7 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 212346.
Shopware is an open source eCommerce platform. Versions prior to 6.4.3.1 contain a command injection vulnerability in mail agent settings. Version 6.4.3.1 contains a patch. As workarounds for older versions of 6.1, 6.2, and 6.3, corresponding security measures are also available via a plugin.
A Command Injection vulnerability exists in the do_upgrade_post function of the httpd binary in Linksys E1500 v1.0.06.001. As a result, an authenticated attacker can execute OS commands with root privileges.
SAP NetWeaver Knowledge Management XML Forms versions - 7.10, 7.11, 7.30, 7.31, 7.40, 7.50, contains an XSLT vulnerability which allows a non-administrative authenticated attacker to craft a malicious XSL stylesheet file containing a script with OS-level commands, copy it into a location to be accessed by the system and then create a file which will trigger the XSLT engine to execute the script contained within the malicious XSL file. This can result in a full compromise of the confidentiality, integrity, and availability of the system.
An issue was discovered in OpenGamePanel OGP-Agent-Linux through 2021-08-14. An authenticated attacker could inject OS commands by starting a Counter-Strike server and using the map field to enter a Bash command.
An authenticated command injection vulnerability exists in the HPE Aruba Networking EdgeConnect SD-WAN gateways Command Line Interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system.
jc21 NGINX Proxy Manager before 2.11.3 allows backend/internal/certificate.js OS command injection by an authenticated user (with certificate management privileges) via untrusted input to the DNS provider configuration. NOTE: this is not part of any NGINX software shipped by F5.
**UNSUPPORTED WHEN ASSIGNED** A post-authentication command injection vulnerability in the management commands of the legacy DSL CPE Zyxel VMG4325-B10A firmware version 1.00(AAFR.4)C0_20170615 could allow an authenticated attacker to execute operating system (OS) commands on an affected device via Telnet.
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote authenticated attacker may execute an arbitrary OS command.
**UNSUPPORTED WHEN ASSIGNED** A post-authentication command injection vulnerability in the CGI program of the legacy DSL CPE Zyxel VMG4325-B10A firmware version 1.00(AAFR.4)C0_20170615 could allow an authenticated attacker to execute operating system (OS) commands on an affected device by sending a crafted HTTP POST request.
A Improper neutralization of special elements used in a command ('Command Injection') in Fortinet FortiWeb version 6.3.13 and below allows attacker to execute unauthorized code or commands via crafted HTTP requests
rejetto HFS (aka HTTP File Server) 3 before 0.52.10 on Linux, UNIX, and macOS allows OS command execution by remote authenticated users (if they have Upload permissions). This occurs because a shell is used to execute df (i.e., with execSync instead of spawnSync in child_process in Node.js).
Multiple improper neutralization of special elements used in a command vulnerabilities [CWE-77] in FortiWeb management interface 6.4.1 and below, 6.3.15 and below, 6.2.5 and below may allow an authenticated attacker to execute unauthorized code or commands via crafted parameters of HTTP requests.
Specially crafted string in OTRS system configuration can allow the execution of any system command.
A improper neutralization of special elements used in an OS command ('OS Command Injection') in Fortinet FortiWLM version 8.6.1 and below allows attacker to execute unauthorized code or commands via crafted HTTP requests.
D-Link DIR-823X firmware - 240126 was discovered to contain a remote command execution (RCE) vulnerability via the dhcpd_startip parameter at /goform/set_lan_settings.
Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response in an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.
An exploitable command injection vulnerability exists in the web server functionality of Moxa EDR-810 V4.1 build 17030317. A specially crafted HTTP POST can cause a privilege escalation resulting in root shell. An attacker can inject OS commands into the remoteNetwork0= parameter in the "/goform/net\_Web\_get_value" uri to trigger this vulnerability.