AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the StorageNode service, which listens on TCP port 9075 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26156.
In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, remote attackers can bypass authentication under certain circumstances because parameters containing 0x00 characters are truncated before reaching the database layer. This occurs because Psycopg 2.x before 2.6.3 is used.
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000.
On Netis WF2411 with firmware 2.1.36123 and other Netis WF2xxx devices (possibly WF2411 through WF2880), there is a stack-based buffer overflow that does not require authentication. This can cause denial of service (device restart) or remote code execution. This vulnerability can be triggered by a GET request with a long HTTP "Authorization: Basic" header that is mishandled by user_auth->user_ok in /bin/boa.
In mintplex-labs/anything-llm v1.5.11 desktop version for Windows, the application opens server port 3001 on 0.0.0.0 with no authentication by default. This vulnerability allows an attacker to gain full backend access, enabling them to perform actions such as deleting all data from the workspace.
A vulnerability in the Policy Builder interface of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to access the Policy Builder interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by accessing the Policy Builder interface. A successful exploit could allow the attacker to make changes to existing repositories and create new repositories. Cisco Bug IDs: CSCvi35109.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
HPE Data Protector before 7.03_108, 8.x before 8.15, and 9.x before 9.06 allow remote attackers to execute arbitrary code via unspecified vectors related to lack of authentication. NOTE: this vulnerability exists because of an incomplete fix for CVE-2014-2623.
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
The nd-restaurant-reservations plugin before 1.5 for WordPress has no requirement for nd_rst_import_settings_php_function authentication.
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
Control Web Panel Missing Authentication Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Control Web Panel. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of authentication within the web interface. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of a valid CWP user. Was ZDI-CAN-20582.
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
RedwoodHQ 2.5.5 does not require any authentication for database operations, which allows remote attackers to create admin users via a con.automationframework users insert_one call.
An Incorrect Access Control vulnerability was found in Wikimedia MediaWiki 1.27.0 through 1.32.1. Directly POSTing to Special:ChangeEmail would allow for bypassing re-authentication, allowing for potential account takeover.
Super Micro SuperDoctor 5, when restrictions are not implemented in agent.cfg, allows remote attackers to execute arbitrary commands via NRPE.
Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers can fully interact with the device: for example, send the "open door" command, download the users list (which includes RFID codes and passcodes in cleartext), or update/create users. The same attack can be executed on a local network and over the internet (if the device is exposed on a public IP address).
An issue was discovered in upgrade_firmware.cgi on VStarcam 100T (C7824WIP) CH-sys-48.53.75.119~123 and 200V (C38S) CH-sys-48.53.203.119~123 devices. A remote command can be executed through a system firmware update without authentication. The attacker can modify the files within the internal firmware or even steal account information by executing a command.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.15 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via the user authentication dialogue, aka HMCCU-153. This leads to automatic login as admin.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin.
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/setSysAdm to edit the web or system account without authentication.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use a hidden API URL /goform/SystemCommand to execute a system command without authentication.
Under certain circumstances, SAP HANA Extended Application Services, advanced model (XS advanced) does not perform authentication checks properly for XS advanced platform and business users. Fixed in 1.0.97 to 1.0.99 (running on SAP HANA 1 or SAP HANA 2 SPS0 (second S stands for stack)).
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/form2userconfig.cgi to edit the system account without authentication.
Contec Smart Home 4.15 devices do not require authentication for new_user.php, edit_user.php, delete_user.php, and user.php, as demonstrated by changing the admin password and then obtaining control over doors.
The default configuration in Apache Cassandra 3.8 through 3.11.1 binds an unauthenticated JMX/RMI interface to all network interfaces, which allows remote attackers to execute arbitrary Java code via an RMI request. This issue is a regression of CVE-2015-0225. The regression was introduced in https://issues.apache.org/jira/browse/CASSANDRA-12109. The fix for the regression is implemented in https://issues.apache.org/jira/browse/CASSANDRA-14173. This fix is contained in the 3.11.2 release of Apache Cassandra.
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices.
A missing authentication for appliance registration vulnerability in Trend Micro Email Encryption Gateway 5.5 could allow an attacker to manipulate the registration process of the product to reset configuration parameters.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device.
An issue was discovered in Zoho ManageEngine Desktop Central 10.0.124 and 10.0.184: missing authentication/authorization for a database query mechanism.
An issue was discovered in Zoho ManageEngine Desktop Central 10.0.124 and 10.0.184: insufficient enforcement of database query type restrictions.
The TP-LINK EAP Controller is TP-LINK's software for remotely controlling wireless access point devices. It utilizes a Java remote method invocation (RMI) service for remote control. The RMI interface does not require any authentication before use, so it lacks user authentication for RMI service commands in EAP controller versions 2.5.3 and earlier. Remote attackers can implement deserialization attacks through the RMI protocol. Successful attacks may allow a remote attacker to remotely control the target server and execute Java functions or bytecode.
SAP NetWeaver System Landscape Directory, LM-CORE 7.10, 7.20, 7.30, 7.31, 7.40, does not perform any authentication checks for functionalities that require user identity.
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the "ssid" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command.
The JMX/RMI interface in Nasdaq BWise 5.0 does not require authentication for an SAP BO Component, which allows remote attackers to execute arbitrary code via a session on port 81.
This vulnerability allows remote attackers to cause a denial-of-service condition on vulnerable installations of ZyXEL P-870H-51 DSL Router 1.00(AWG.3)D5. Authentication is not required to exploit this vulnerability. The specific flaw exists within numerous exposed CGI endpoints. The vulnerability is caused by improper access controls that allow access to critical functions without authentication. An attacker can use this vulnerability to reboot affected devices, along with other actions. Was ZDI-CAN-4540.
In Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100, ports 30001/TCP to 30003/TCP listen for arbitrary URScript code and execute the code. This enables a remote attacker who has access to the ports to remotely execute code that may allow root access to be obtained.
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.
A vulnerability in the Policy Builder database of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to connect directly to the Policy Builder database. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by connecting directly to the Policy Builder database. A successful exploit could allow the attacker to access and change any data in the Policy Builder database. Cisco Bug IDs: CSCvh06134.
A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges.
A vulnerability in the Open Systems Gateway initiative (OSGi) interface of Cisco Policy Suite before 18.1.0 could allow an unauthenticated, remote attacker to directly connect to the OSGi interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by directly connecting to the OSGi interface. An exploit could allow the attacker to access or change any files that are accessible by the OSGi process. Cisco Bug IDs: CSCvh18017.
A vulnerability in the REST API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to access the back-end database of an affected system. The vulnerability exists because the affected software does not properly authenticate REST API calls. An attacker could exploit this vulnerability by obtaining a cross-site request forgery (CSRF) token and then using the token with REST API requests. A successful exploit could allow the attacker to access the back-end database of the affected device and read, alter, or drop information.