The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker may access internal files of ABB SREA-01 and SREA-50 legacy remote monitoring tools without any authorization over the network using a HTTP request which refers to files using ../../ relative paths. Once the internal password file is retrieved, the password hash can be identified using a brute force attack. There is also an exploit allowing running of commands after authorization.
In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.
In ABB IP GATEWAY 3.39 and prior, some configuration files contain passwords stored in plain-text, which may allow an attacker to gain unauthorized access.
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling.
In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process.
In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present on the DBMS file system and in some cases issue commands to the operating system. This can lead to a loss of confidentiality and data integrity or even affect the product behavior and its availability.
The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them).
IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port.
Standalone clients connecting to SAP NetWeaver AS Java via P4 Protocol, versions (SAP-JEECOR 7.00, 7.01; SERVERCOR 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50; CORE-TOOLS 7.00, 7.01, 7.02, 7.05, 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50) do not perform any authentication checks for operations that require user identity leading to Authentication Bypass.
Zoho ManageEngine ServiceDesk Plus before 11306, ServiceDesk Plus MSP before 10530, and SupportCenter Plus before 11014 are vulnerable to unauthenticated remote code execution. This is related to /RestAPI URLs in a servlet, and ImportTechnicians in the Struts configuration.
A vulnerability is in the 'wx.html' page of the WAVLINK AC1200, version WAVLINK-A42W-1.27.6-20180418, which can allow a remote attacker to access this page without any authentication. When an unauthorized user accesses this page directly, it connects to this device as a friend of the device owner.
An issue was discovered in Reprise RLM 14.2. Because /goform/change_password_process does not verify authentication or authorization, an unauthenticated user can change the password of any existing user. This allows an attacker to change the password of any known user, thereby preventing valid users from accessing the system and granting the attacker full access to that user's account.
In Apache APISIX Dashboard before 2.10.1, the Manager API uses two frameworks and introduces framework `droplet` on the basis of framework `gin`, all APIs and authentication middleware are developed based on framework `droplet`, but some API directly use the interface of framework `gin` thus bypassing the authentication.
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The HTTP service (default port 5401/tcp) of the SiVMS/SiNVR Video Server contains an authentication bypass vulnerability, even when properly configured with enforced authentication. A remote attacker with network access to the Video Server could exploit this vulnerability to read the SiVMS/SiNVR users database, including the passwords of all users in obfuscated cleartext.
Spinnaker is an open source, multi-cloud continuous delivery platform. Spinnaker has improper permissions allowing pipeline creation & execution. This lets an arbitrary user with access to the gate endpoint to create a pipeline and execute it without authentication. If users haven't setup Role-based access control (RBAC) with-in spinnaker, this enables remote execution and access to deploy almost any resources on any account. Patches are available on the latest releases of the supported branches and users are advised to upgrade as soon as possible. Users unable to upgrade should enable RBAC on ALL accounts and applications. This mitigates the ability of a pipeline to affect any accounts. Block application access unless permission are enabled. Users should make sure ALL application creation is restricted via appropriate wildcards.
Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the "ssid" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command.
AriaNg v0.1.0~v1.2.2 is affected by an incorrect access control vulnerability through not authenticating visitors' access rights.
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
Jector Smart TV FM-K75 devices allow remote code execution because there is an adb open port with root permission.
An issue was discovered on D-Link DIR-878 1.12B01 devices. Because strncpy is misused, there is a stack-based buffer overflow vulnerability that does not require authentication via the HNAP_AUTH HTTP header.
eQ-3 Homematic CCU2 prior to 2.47.10 and CCU3 prior to 3.47.10 JSON API has Improper Access Control for Interface.***Metadata related operations, resulting in the ability to read, set and deletion of Metadata.
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.
In Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100, ports 30001/TCP to 30003/TCP listen for arbitrary URScript code and execute the code. This enables a remote attacker who has access to the ports to remotely execute code that may allow root access to be obtained.
On Netis WF2411 with firmware 2.1.36123 and other Netis WF2xxx devices (possibly WF2411 through WF2880), there is a stack-based buffer overflow that does not require authentication. This can cause denial of service (device restart) or remote code execution. This vulnerability can be triggered by a GET request with a long HTTP "Authorization: Basic" header that is mishandled by user_auth->user_ok in /bin/boa.
The WPGraphQL 0.2.3 plugin for WordPress allows remote attackers to register a new user with admin privileges, whenever new user registrations are allowed. This is related to the registerUser mutation.
The JMX/RMI interface in Nasdaq BWise 5.0 does not require authentication for an SAP BO Component, which allows remote attackers to execute arbitrary code via a session on port 81.
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
A vulnerability in the Redis implementation used by the Cisco Policy Suite for Mobile and Cisco Policy Suite Diameter Routing Agent software could allow an unauthenticated, remote attacker to modify key-value pairs for short-lived events stored by the Redis server. The vulnerability is due to improper authentication when accessing the Redis server. An unauthenticated attacker could exploit this vulnerability by modifying key-value pairs stored within the Redis server database. An exploit could allow the attacker to reduce the efficiency of the Cisco Policy Suite for Mobile and Cisco Policy Suite Diameter Routing Agent software.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
A vulnerability in the Open Systems Gateway initiative (OSGi) interface of Cisco Policy Suite before 18.1.0 could allow an unauthenticated, remote attacker to directly connect to the OSGi interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by directly connecting to the OSGi interface. An exploit could allow the attacker to access or change any files that are accessible by the OSGi process. Cisco Bug IDs: CSCvh18017.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the Script Parser AddOn through 1.8 installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi script, which executes TCL script content from an HTTP POST request.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
A vulnerability in the Policy Builder database of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to connect directly to the Policy Builder database. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by connecting directly to the Policy Builder database. A successful exploit could allow the attacker to access and change any data in the Policy Builder database. Cisco Bug IDs: CSCvh06134.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
wan.htm page on Zyxel NBG-418N v2 with firmware version V1.00(AARP.9)C0 can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify data fields of the page.
An issue was discovered in the LifterLMS plugin through 3.34.5 for WordPress. The upload_import function in the class.llms.admin.import.php script is prone to an unauthenticated options import vulnerability that could lead to privilege escalation (administrator account creation), website redirection, and stored XSS.
eQ-3 Homematic CCU2 before 2.47.18 and CCU3 before 3.47.18 allow Remote Code Execution by unauthenticated attackers with access to the web interface via an HTTP POST request to certain URLs related to the ReGa core process.
The nd-restaurant-reservations plugin before 1.5 for WordPress has no requirement for nd_rst_import_settings_php_function authentication.
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
HiNet GPON firmware version < I040GWR190731 allows an attacker login to device without any authentication.