Incorrect access control in the database manager component in Odoo Community 10.0 and 11.0 and Odoo Enterprise 10.0 and 11.0 allows a remote attacker to restore a database dump without knowing the super-admin password. An arbitrary password succeeds.
In mintplex-labs/anything-llm v1.5.11 desktop version for Windows, the application opens server port 3001 on 0.0.0.0 with no authentication by default. This vulnerability allows an attacker to gain full backend access, enabling them to perform actions such as deleting all data from the workspace.
A vulnerability in the user registration component found in the ~/src/Classes/RegistrationAuth.php file of the ProfilePress WordPress plugin made it possible for users to register on sites as an administrator. This issue affects versions 3.0.0 - 3.1.3. .
The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.
Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an attacker to enable the SNMP service and manipulate the community strings to achieve further control in.
The variable import endpoint was not protected by authentication in Airflow >=2.0.0, <2.1.3. This allowed unauthenticated users to hit that endpoint to add/modify Airflow variables used in DAGs, potentially resulting in a denial of service, information disclosure or remote code execution. This issue affects Apache Airflow >=2.0.0, <2.1.3.
A security vulnerability has been detected in JeecgBoot 3.9.0/3.9.1. The impacted element is an unknown function of the file jeecg-boot/jeecg-module-system/jeecg-system-biz/src/main/java/org/jeecg/modules/airag/JeecgBizToolsProvider.java of the component AI Chat Module. Such manipulation leads to missing authentication. The attack can be executed remotely. The name of the patch is b7c9aeba7aefda9e008ea8fe4fc3daf08d0c5b39/2c1cc88b8d983868df8c520a343d6ff4369d9e59. It is best practice to apply a patch to resolve this issue. The project fixed the issue with a commit which shall be part of the next official release.
An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access.
Zoho ManageEngine ServiceDesk Plus before 11302 is vulnerable to authentication bypass that allows a few REST-API URLs without authentication.
The resolution SAML SSO apps for Atlassian products allow a remote attacker to login to a user account when only the username is known (i.e., no other authentication is provided). The fixed versions are for Jira: 3.6.6.1, 4.0.12, 5.0.5; for Confluence 3.6.6, 4.0.12, 5.0.5; for Bitbucket 2.5.9, 3.6.6, 4.0.12, 5.0.5; for Bamboo 2.5.9, 3.6.6, 4.0.12, 5.0.5; and for Fisheye 2.5.9.
Authentication Bypass vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to change or update any configuration settings, or gain administrator functionality via a crafted HTTP request parameter.
WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186).
Unauthenticated Arbitrary Options Update vulnerability leading to full website compromise discovered in Image Hover Effects Ultimate (versions <= 9.6.1) WordPress plugin.
An issue was discovered in Echo ShareCare 8.15.5. It does not perform authentication or authorization checks when accessing a subset of sensitive resources, leading to the ability for unauthenticated users to access pages that are vulnerable to attacks such as SQL injection.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Unauthenticated API Endpoints.
Multiple camera devices by UDP Technology, Geutebrück and other vendors allow unauthenticated remote access to sensitive files due to default user authentication settings. This can lead to manipulation of the device and denial of service.
The affected product’s configuration is vulnerable due to missing authentication, which may allow an attacker to change configurations and execute arbitrary code on the iView (versions prior to v5.7.03.6182).
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
The WPGraphQL 0.2.3 plugin for WordPress allows remote attackers to register a new user with admin privileges, whenever new user registrations are allowed. This is related to the registerUser mutation.
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Firmware can be updated over the network without authentication, which may allow remote code execution.
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.
A request-validation issue was discovered in Open5GS 2.1.3 through 2.2.x before 2.2.1. The WebUI component allows an unauthenticated user to use a crafted HTTP API request to create, read, update, or delete entries in the subscriber database. For example, new administrative users can be added. The issue occurs because Express is not set up to require authentication.
A vulnerability in the Policy Builder database of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to connect directly to the Policy Builder database. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by connecting directly to the Policy Builder database. A successful exploit could allow the attacker to access and change any data in the Policy Builder database. Cisco Bug IDs: CSCvh06134.
There is no account authentication and permission check logic in the firmware and existing apps of SiHAS's SGW-300, ACM-300, GCM-300, so unauthorized users can remotely control the device.
OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000.
HGiga EIP product lacks ineffective access control in certain pages that allow attackers to access database or perform privileged functions.
Access to the Advantech iView versions prior to v5.7.03.6112 configuration are missing authentication, which may allow an unauthorized attacker to change the configuration and obtain code execution.
In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
Trendnet AC2600 TEW-827DRU version 2.08B01 contains an authentication bypass vulnerability. It is possible for an unauthenticated, malicous actor to force the change of the admin password due to a hidden administrative command.
An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot.
Trustwave Secure Web Gateway (SWG) through 11.8.0.27 allows remote attackers to append an arbitrary public key to the device's SSH Authorized Keys data, and consequently obtain remote root access, via the publicKey parameter to the /sendKey URI.
Vulnerability in the Oracle Access Manager product of Oracle Fusion Middleware (component: OpenSSO Agent). Supported versions that are affected are 11.1.2.3.0, 12.2.1.3.0 and 12.2.1.4.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Access Manager. Successful attacks of this vulnerability can result in takeover of Oracle Access Manager. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
admin.php in Frax.dk Php Recommend 1.3 and earlier does not require authentication when the user password is changed, which allows remote attackers to gain administrative privileges via modified form_admin_user and form_admin_pass parameters.
IBM Security Identity Manager Adapters 6.0 and 7.0 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 128621.
A vulnerability exists allowing attackers, when present in the same network segment as ClearPass' management interface, to make changes to certain databases in ClearPass by crafting HTTP packets. As a result of this attack, a possible complete cluster compromise might occur. Resolution: Fixed in 6.7.13, 6.8.4, 6.9.0 and higher.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
Standalone clients connecting to SAP NetWeaver AS Java via P4 Protocol, versions (SAP-JEECOR 7.00, 7.01; SERVERCOR 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50; CORE-TOOLS 7.00, 7.01, 7.02, 7.05, 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50) do not perform any authentication checks for operations that require user identity leading to Authentication Bypass.
A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution.
register_send.php on D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices does not require authentication, which can result in unintended enrollment in mydlink Cloud Services.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
SAP Solution Manager (Diagnostics Agent), version 720, allows unencrypted connections from unauthenticated sources. This allows an attacker to control all remote functions on the Agent due to Missing Authentication Check.
A vulnerability was determined in DataLinkDC dinky up to 1.2.5. This affects the function addInterceptors of the file dinky-admin/src/main/java/org/dinky/configure/AppConfig.java of the component OpenAPI Endpoint. Executing a manipulation can lead to missing authentication. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.
A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges.
Remote enabling and disabling admin interface in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK RTE version 7.55 leads to new attack vectors.
A security flaw has been discovered in ChurchCRM up to 5.18.0. This impacts the function AuthMiddleware of the file src/ChurchCRM/Slim/Middleware/AuthMiddleware.php of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks. The patch is identified as 3a1cffd2aea63d884025949cfbcfd274d06216a4. A patch should be applied to remediate this issue.