Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2026-8179

Summary
Assigner-ibm
Assigner Org ID-9a959283-ebb5-44b6-b705-dcc2bbced522
Published At-27 May, 2026 | 13:17
Updated At-28 May, 2026 | 03:55
Rejected At-
Credits

Multiple vulnerabilities in Aspera applications.

IBM Aspera High-Speed Transfer Endpoint 3.7.4 through 4.4.7 Fix Pack 1 and IBM Aspera High-Speed Transfer Server 3.7.4 through 4.4.7 Fix Pack 1 and IBM Aspera High-Speed Transfer Endpoint are affected by a buffer overflow in the asperahttpd component. This vulnerability could allow an authenticated user to execute arbitrary code on the system.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:ibm
Assigner Org ID:9a959283-ebb5-44b6-b705-dcc2bbced522
Published At:27 May, 2026 | 13:17
Updated At:28 May, 2026 | 03:55
Rejected At:
▼CVE Numbering Authority (CNA)
Multiple vulnerabilities in Aspera applications.

IBM Aspera High-Speed Transfer Endpoint 3.7.4 through 4.4.7 Fix Pack 1 and IBM Aspera High-Speed Transfer Server 3.7.4 through 4.4.7 Fix Pack 1 and IBM Aspera High-Speed Transfer Endpoint are affected by a buffer overflow in the asperahttpd component. This vulnerability could allow an authenticated user to execute arbitrary code on the system.

Affected Products
Vendor
IBM CorporationIBM
Product
Aspera High-Speed Transfer Endpoint
CPEs
  • cpe:2.3:a:ibm:aspera_high_speed_transfer_endpoint:3.7.4:*:*:*:*:*:*:*
  • cpe:2.3:a:ibm:aspera_high_speed_transfer_endpoint:4.4.7:*:*:*:*:*:*:*
Versions
Affected
  • From 3.7.4 through 4.4.7 Fix Pack 1 (semver)
Vendor
IBM CorporationIBM
Product
Aspera High-Speed Transfer Server
CPEs
  • cpe:2.3:a:ibm:aspera_high_speed_transfer_server:3.7.4:*:*:*:*:*:*:*
  • cpe:2.3:a:ibm:aspera_high_speed_transfer_server:4.4.7:*:*:*:*:*:*:*
Versions
Affected
  • From 3.7.4 through 4.4.7 Fix Pack 1 (semver)
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Product(s)VRMFRemediation/First FixIBM Aspera High-Speed Transfer Server4.4.7 Fix Pack 2Link to latest release (4.4.7 FP 2)IBM Aspera High-Speed Transfer Endpoint4.4.7 Fix Pack 2Link to latest release (4.4.7 FP 2)

Configurations

Workarounds

Exploits

Credits

finder
The vulnerabilities were reported to IBM by Yannik Marchand.
Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.ibm.com/support/pages/node/7273615
vendor-advisory
patch
Hyperlink: https://www.ibm.com/support/pages/node/7273615
Resource:
vendor-advisory
patch
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:psirt@us.ibm.com
Published At:27 May, 2026 | 14:17
Updated At:27 May, 2026 | 14:53

IBM Aspera High-Speed Transfer Endpoint 3.7.4 through 4.4.7 Fix Pack 1 and IBM Aspera High-Speed Transfer Server 3.7.4 through 4.4.7 Fix Pack 1 and IBM Aspera High-Speed Transfer Endpoint are affected by a buffer overflow in the asperahttpd component. This vulnerability could allow an authenticated user to execute arbitrary code on the system.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-121Primarypsirt@us.ibm.com
CWE ID: CWE-121
Type: Primary
Source: psirt@us.ibm.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.ibm.com/support/pages/node/7273615psirt@us.ibm.com
N/A
Hyperlink: https://www.ibm.com/support/pages/node/7273615
Source: psirt@us.ibm.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

889Records found

CVE-2024-2806
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.95%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-21 Aug, 2024 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 addWifiMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2811
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 67.66%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:00
Updated-21 Aug, 2024 | 22:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WifiWpsStart formWifiWpsStart stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-27129
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-6.4||MEDIUM
EPSS-0.32% / 55.02%
||
7 Day CHG~0.00%
Published-21 May, 2024 | 16:08
Updated-11 Sep, 2024 | 13:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
QTS, QuTS hero

A buffer copy without checking size of input vulnerability has been reported to affect several QNAP operating system versions. If exploited, the vulnerability could allow authenticated users to execute code via a network. We have already fixed the vulnerability in the following version: QTS 5.1.7.2770 build 20240520 and later QuTS hero h5.1.7.2770 build 20240520 and later

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-quts_heroqtsQuTS heroQTSquts_heroqts
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-2708
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.54%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2709
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.13% / 32.63%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49909
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 75.35%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `action` parameter at offset `0x0045ab38` of the `httpd_portal` binary shipped with v5.1.0 Build 20220926 of the EAP225.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap225eap225_firmwareAC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49912
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 75.35%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `profile` parameter at offset `0x4224b0` of the `httpd` binary shipped with v5.0.4 Build 20220216 of the EAP115.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap115_firmwareeap225eap225_firmwareeap115AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2581
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.48% / 65.62%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 03:00
Updated-22 Jan, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49913
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 75.35%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `action` parameter at offset `0x422448` of the `httpd` binary shipped with v5.0.4 Build 20220216 of the EAP115.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap115_firmwareeap225eap225_firmwareeap115AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49911
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 75.35%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `band` parameter at offset `0x422420` of the `httpd` binary shipped with v5.0.4 Build 20220216 of the EAP115.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap115_firmwareeap225eap225_firmwareeap115AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-3921
Matching Score-4
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-4
Assigner-Tenable Network Security, Inc.
CVSS Score-8.8||HIGH
EPSS-5.49% / 90.36%
||
7 Day CHG~0.00%
Published-05 Mar, 2019 | 21:00
Updated-17 Sep, 2024 | 04:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 is vulnerable to a stack buffer overflow via crafted HTTP POST request sent by a remote, authenticated attacker to /GponForm/usb_Form?script/. An attacker can leverage this vulnerability to potentially execute arbitrary code.

Action-Not Available
Vendor-Tenable, Inc.Nokia Corporation
Product-i-240w-q_gpon_ont_firmwarei-240w-q_gpon_ontAlcatel Lucent I-240W-Q GPON ONT
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-35322
Matching Score-4
Assigner-Microsoft Corporation
ShareView Details
Matching Score-4
Assigner-Microsoft Corporation
CVSS Score-8.8||HIGH
EPSS-2.46% / 85.49%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 17:02
Updated-01 Jan, 2025 | 01:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Windows Deployment Services Remote Code Execution Vulnerability

Windows Deployment Services Remote Code Execution Vulnerability

Action-Not Available
Vendor-Microsoft Corporation
Product-windows_server_2016windows_server_2012windows_server_2022windows_server_2019windows_server_2008Windows Server 2022Windows Server 2008 R2 Service Pack 1Windows Server 2019 (Server Core installation)Windows Server 2008 Service Pack 2 (Server Core installation)Windows Server 2008 R2 Service Pack 1 (Server Core installation)Windows Server 2008 Service Pack 2Windows Server 2012 R2Windows Server 2016 (Server Core installation)Windows Server 2008 Service Pack 2Windows Server 2012Windows Server 2012 (Server Core installation)Windows Server 2019Windows Server 2012 R2 (Server Core installation)Windows Server 2016
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2019-5153
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-2.27% / 84.92%
||
7 Day CHG~0.00%
Published-25 Feb, 2020 | 15:48
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable remote code execution vulnerability exists in the iw_webs configuration parsing functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted user name entry can cause an overflow of an error message buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-awk-3131aawk-3131a_firmwareMoxa
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10123
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.65% / 71.21%
||
7 Day CHG~0.00%
Published-18 Oct, 2024 | 19:31
Updated-28 Oct, 2024 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0536
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.09%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 03:31
Updated-17 Jun, 2025 | 21:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd setWrlAccessList stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda W9 1.0.0.7(4456). Affected by this issue is the function setWrlAccessList of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-250706 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-13556
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.11% / 78.46%
||
7 Day CHG~0.00%
Published-18 Sep, 2019 | 21:05
Updated-04 Aug, 2024 | 23:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In WebAccess versions 8.4.1 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.

Action-Not Available
Vendor-n/aAdvantech (Advantech Co., Ltd.)
Product-webaccessWebAccess
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-10164
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-7.5||HIGH
EPSS-11.38% / 93.67%
||
7 Day CHG-2.01%
Published-26 Jun, 2019 | 15:29
Updated-04 Aug, 2024 | 22:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

PostgreSQL versions 10.x before 10.9 and versions 11.x before 11.4 are vulnerable to a stack-based buffer overflow. Any authenticated user can overflow a stack-based buffer by changing the user's own password to a purpose-crafted value. This often suffices to execute arbitrary code as the PostgreSQL operating system account.

Action-Not Available
Vendor-openSUSEThe PostgreSQL Global Development GroupFedora ProjectRed Hat, Inc.
Product-enterprise_linuxpostgresqlfedoraleapPostgreSQL
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-48725
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-31.74% / 96.88%
||
7 Day CHG~0.00%
Published-07 Mar, 2024 | 14:59
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the JSON Parsing getblockschedule() functionality of Netgear RAX30 1.0.11.96 and 1.0.7.78. A specially crafted HTTP request can lead to code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-rax30_firmwarerax30RAX30rax30_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49906
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 75.35%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `ssid` parameter at offset `0x0045ab7c` of the `httpd_portal` binary shipped with v5.1.0 Build 20220926 of the EAP225.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap225eap225_firmwareAC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49910
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-0.86% / 75.35%
||
7 Day CHG~0.00%
Published-09 Apr, 2024 | 14:12
Updated-04 Nov, 2025 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the web interface Radio Scheduling functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926. A specially crafted series of HTTP requests can lead to remote code execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.This vulnerability refers specifically to the overflow that occurs via the `ssid` parameter at offset `0x42247c` of the `httpd` binary shipped with v5.0.4 Build 20220216 of the EAP115.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-eap115_firmwareeap225eap225_firmwareeap115AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3)N300 Wireless Access Point (EAP115)ac1350_firmwaren300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-9791
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.52% / 66.95%
||
7 Day CHG+0.05%
Published-01 Sep, 2025 | 19:02
Updated-04 Sep, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 fromAdvSetMacMtuWan stack-based overflow

A weakness has been identified in Tenda AC20 16.03.08.05. This vulnerability affects unknown code of the file /goform/fromAdvSetMacMtuWan. This manipulation of the argument wanMTU causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-41028
Matching Score-4
Assigner-Exodus Intelligence
ShareView Details
Matching Score-4
Assigner-Exodus Intelligence
CVSS Score-9||CRITICAL
EPSS-0.14% / 34.64%
||
7 Day CHG~0.00%
Published-23 Aug, 2023 | 21:47
Updated-03 Oct, 2024 | 13:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Juplink RX4-1500 Stack-based Buffer Overflow Vulnerability

A stack-based buffer overflow exists in Juplink RX4-1500, a WiFi router, in versions 1.0.2 through 1.0.5. An authenticated attacker can exploit this vulnerability to achieve code execution as root.

Action-Not Available
Vendor-juplinkJuplinkjuplink
Product-rx4-1500_firmwarerx4-1500RX4-1500rx4-1500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-8833
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.31% / 54.76%
||
7 Day CHG+0.02%
Published-11 Aug, 2025 | 06:02
Updated-04 Sep, 2025 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 langSwitchBack stack-based overflow

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function langSwitchBack of the file /goform/langSwitchBack. The manipulation of the argument langSelectionOnly leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE6250RE7000RE6500RE9000
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-9089
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.32% / 54.87%
||
7 Day CHG~0.00%
Published-16 Aug, 2025 | 23:32
Updated-21 Aug, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 SetIpMacBind sub_48E628 stack-based overflow

A vulnerability was determined in Tenda AC20 16.03.08.12. This issue affects the function sub_48E628 of the file /goform/SetIpMacBind. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-9248
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.36% / 58.51%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 21:02
Updated-02 Sep, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_pingGatewayByBBS stack-based overflow

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. The impacted element is the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ssidhex results in stack-based buffer overflow. The attack may be performed from a remote location. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re9000_firmwarere6350re6500re6250_firmwarere7000re7000_firmwarere6250re6350_firmwarere9000re6300_firmwarere6500_firmwareRE6250RE6300RE7000RE9000RE6500RE6350
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-7505
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.89% / 75.76%
||
7 Day CHG~0.00%
Published-12 Jul, 2025 | 22:32
Updated-15 Jul, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH451 HTTP POST Request L7Prot frmL7ProtForm stack-based overflow

A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function frmL7ProtForm of the file /goform/L7Prot of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh451_firmwarefh451FH451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-7910
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.98% / 83.88%
||
7 Day CHG~0.00%
Published-20 Jul, 2025 | 22:02
Updated-22 Jul, 2025 | 13:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-513 Boa Webserver formSetWanNonLogin sprintf stack-based overflow

A vulnerability classified as critical has been found in D-Link DIR-513 1.10. This affects the function sprintf of the file /goform/formSetWanNonLogin of the component Boa Webserver. The manipulation of the argument curTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-513
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-7416
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.57% / 81.82%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 21:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setSysTimeInfo fromSysToolTime stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda O3V2 1.0.0.12(3880). Affected is the function fromSysToolTime of the file /goform/setSysTimeInfo of the component httpd. The manipulation of the argument Time leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-8017
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.64% / 82.25%
||
7 Day CHG~0.00%
Published-22 Jul, 2025 | 13:32
Updated-01 Aug, 2025 | 20:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 httpd setMacFilterCfg formSetMacFilterCfg stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-7596
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.57% / 81.82%
||
7 Day CHG~0.00%
Published-14 Jul, 2025 | 10:32
Updated-17 Jul, 2025 | 17:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 WifiExtraSet formWifiExtraSet stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been rated as critical. This issue affects the function formWifiExtraSet of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205fh1205_firmwareFH1205
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7419
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.57% / 81.82%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 23:02
Updated-16 Jul, 2025 | 16:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setRateTest fromSpeedTestSet stack-based overflow

A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been classified as critical. This affects the function fromSpeedTestSet of the file /goform/setRateTest of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-7586
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.57% / 81.82%
||
7 Day CHG~0.00%
Published-14 Jul, 2025 | 08:02
Updated-17 Jul, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 setWtpData formSetAPCfg stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500_firmwareac500AC500
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-39435
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.85%
||
7 Day CHG~0.00%
Published-08 Nov, 2023 | 22:54
Updated-16 Jan, 2025 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Zavio IP Camera Stack-Based Buffer Overflow

Zavio CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220, CB6231, B8520, B8220, and CD321 IP Cameras with firmware version M2.1.6.05 are vulnerable to stack-based overflows. During the process of updating certain settings sent from incoming network requests, the product does not sufficiently check or validate allocated buffer size. This may lead to remote code execution.

Action-Not Available
Vendor-zavioZavio
Product-cf7201cf7300cb5220cf7501cf7500_firmwarecb3211_firmwarecf7300_firmwarecb3212cf7501_firmwareb8220_firmwarecb3212_firmwarecb6231_firmwareb8520cb5220_firmwarecb6231b8220cd321b8520_firmwarecb3211cf7201_firmwarecf7500cd321_firmwareIP Camera B8220IP Camera CB3212IP Camera CB5220IP Camera CD321IP Camera CB3211IP Camera CF7300IP Camera CB6231IP Camera CF7201IP Camera CF7500IP Camera CF7501IP Camera B8520
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7089
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.16% / 78.92%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 18:32
Updated-09 Jul, 2025 | 17:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs formWanTcpipSetup stack-based overflow

A vulnerability was found in Belkin F9K1122 1.00.33 and classified as critical. This issue affects the function formWanTcpipSetup of the file /goform/formWanTcpipSetup of the component webs. The manipulation of the argument pppUserName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-7092
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.16% / 78.92%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 20:02
Updated-09 Jul, 2025 | 17:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs formWlanSetupWPS stack-based overflow

A vulnerability has been found in Belkin F9K1122 1.00.33 and classified as critical. This vulnerability affects the function formWlanSetupWPS of the file /goform/formWlanSetupWPS of the component webs. The manipulation of the argument wps_enrolee_pin/webpage leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-6510
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.90% / 75.99%
||
7 Day CHG~0.00%
Published-23 Jun, 2025 | 16:00
Updated-16 Jul, 2025 | 17:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear EX6100 sub_415EF8 stack-based overflow

A vulnerability was found in Netgear EX6100 1.0.2.28_1.1.138. It has been rated as critical. Affected by this issue is the function sub_415EF8. The manipulation leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-ex6100_firmwareex6100EX6100
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-24018
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-0.23% / 46.33%
||
7 Day CHG~0.00%
Published-06 Jul, 2023 | 14:53
Updated-02 Aug, 2024 | 10:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the libzebra.so.0.0.0 security_decrypt_password functionality of Milesight UR32L v32.3.0.5. A specially crafted HTTP request can lead to a buffer overflow. An authenticated attacker can send an HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-Milesight
Product-ur32l_firmwareur32lUR32Lur32l_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-10907
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-8.8||HIGH
EPSS-2.06% / 84.19%
||
7 Day CHG~0.00%
Published-04 Sep, 2018 | 13:00
Updated-05 Aug, 2024 | 07:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

It was found that glusterfs server is vulnerable to multiple stack based buffer overflows due to functions in server-rpc-fopc.c allocating fixed size buffers using 'alloca(3)'. An authenticated attacker could exploit this by mounting a gluster volume and sending a string longer that the fixed buffer size to cause crash or potential code execution.

Action-Not Available
Vendor-glusterDebian GNU/LinuxRed Hat, Inc.openSUSE
Product-enterprise_linux_serverdebian_linuxvirtualization_hostglusterfsleapglusterfs
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-10607
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.79% / 74.22%
||
7 Day CHG~0.00%
Published-27 Mar, 2020 | 13:27
Updated-04 Aug, 2024 | 11:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Advantech WebAccess, Versions 8.4.2 and prior. A stack-based buffer overflow vulnerability caused by a lack of proper validation of the length of user-supplied data may allow remote code execution.

Action-Not Available
Vendor-n/aAdvantech (Advantech Co., Ltd.)
Product-webaccessAdvantech WebAccess
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • ...
  • 16
  • 17
  • 18
  • Next
Details not found