A vulnerability was detected in Edimax BR-6228NC 1.22. Affected by this issue is the function mp of the file /goform/mp of the component POST Request Handler. The manipulation of the argument command results in command injection. The attack may be performed from remote. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A weakness has been identified in Edimax BR-6428nC up to 1.16. This affects an unknown function of the file /goform/setWAN of the component Web Interface. This manipulation of the argument pppUserName/pptpUserName causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
A security flaw has been discovered in Edimax BR-6208AC 1.02. The impacted element is the function setWAN of the file /goform/setWAN of the component L2TP Mode. The manipulation of the argument L2TPUserName results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
A security vulnerability has been detected in Edimax BR-6478AC V3 1.0.15. This issue affects the function sub_416898 of the file /boafrm/formDebugDiagnosticRun. The manipulation of the argument host leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was detected in Edimax BR-6478AC V3 1.0.15. Impacted is the function sub_416990 of the file /boafrm/formTracerouteDiagnosticRun. The manipulation of the argument host results in os command injection. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A flaw has been found in Edimax BR-6478AC V3 1.0.15. The affected element is the function sub_44CCE4 of the file /boafrm/formSysCmd. This manipulation of the argument sysCmd causes os command injection. The attack may be initiated remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Edimax IC-6220DC and IC-5150W up to 3.06. It has been rated as critical. Affected by this issue is the function cgiFormString of the file ipcam_cgi. The manipulation of the argument host leads to command injection. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formRoute of the component Web-based Configuration Interface. The manipulation of the argument strIp/strMask/strGateway results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.58, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.108, and XR700 before 1.0.1.20.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
A vulnerability, which was classified as critical, was found in PHPGurukul Teacher Subject Allocation Management System 1.0. This affects an unknown part of the file /admin/edit-teacher-info.php. The manipulation of the argument editid leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GS108Tv2 before 5.4.2.36, GS110TPP before 7.0.7.2, GS110TPv2 before 5.4.2.36., GS110TPv3 before 7.0.7.2, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.
NETGEAR D6220 devices before 1.0.0.76 are affected by command injection by an authenticated user.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7000 before 1.0.11.126, R6900P before 1.3.2.126, and R7000P before 1.3.2.126.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900P before 1.4.2.84, R7960P before 1.4.2.84, and R8000P before 1.4.2.84.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
There are command injection vulnerabilities present in the AirWave application. Certain input fields controlled by an administrative user are not properly sanitized before being parsed by AirWave. If conditions are met, an attacker can obtain command execution on the host.
A vulnerability classified as critical was found in PHPGurukul Daily Expense Tracker System 1.1. This vulnerability affects unknown code of the file /expense-reports-detailed.php. The manipulation of the argument fromdate/todate leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230722 and classified as critical. This issue affects some unknown processing of the file importhtml.php. The manipulation of the argument sql leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-235967. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS850 before 3.2.17.12.
In Sophos Web Appliance (SWA) before 4.3.1.2, a section of the machine's interface responsible for generating reports was vulnerable to remote command injection via the token parameter, aka NSWA-1303.
In Sophos Web Appliance (SWA) before 4.3.1.2, a section of the machine's configuration utilities for adding (and detecting) Active Directory servers was vulnerable to remote command injection, aka NSWA-1314.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GC108P before 1.0.8.2, GC108PP before 1.0.8.2, GS108Tv3 before 7.0.7.2, GS110TPv3 before 7.0.7.2, GS110TPP before 7.0.7.2, GS110TUP before 1.0.5.3, GS710TUP before 1.0.5.3, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS710TUP before 1.0.5.3, GS716TP before 1.0.4.2, GS716TPP before 1.0.4.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS724TPP before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS750E before 1.0.1.10, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects LBR20 before 2.6.3.50, RBS50Y before 2.7.3.22, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22.
A vulnerability has been found in PHPGurukul Teacher Subject Allocation Management System 1.0 and classified as critical. This vulnerability affects unknown code of the file /admin/edit-course.php. The manipulation of the argument editid leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
The Symantec Messaging Gateway before 10.6.3-267 can encounter an issue of remote code execution, which describes a situation whereby an individual may obtain the ability to execute commands remotely on a target machine or in a target process. In this type of occurrence, after gaining access to the system, the attacker may attempt to elevate their privileges.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6200 before 1.1.00.40, D7000 before 1.0.1.78, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.26, JR6150 before 1.0.1.26, R6120 before 1.0.0.66, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.64, R6800 before 1.2.0.62, R6700v2 before 1.2.0.62, R6900v2 before 1.2.0.62, R7450 before 1.2.0.62, AC2100 before 1.2.0.62, AC2400 before 1.2.0.62, AC2600 before 1.2.0.62, and WNR2020 before 1.1.0.62.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects AC2100 before 1.2.0.88, AC2400 before 1.2.0.88, AC2600 before 1.2.0.88, D7000 before 1.0.1.82, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.84, R6330 before 1.1.0.84, R6350 before 1.1.0.84, R6700v2 before 1.2.0.88, R6800 before 1.2.0.88, R6850 before 1.1.0.84, R6900v2 before 1.2.0.88, R7200 before 1.2.0.88, R7350 before 1.2.0.88, R7400 before 1.2.0.88, and R7450 before 1.2.0.88.
A security flaw has been discovered in Dromara MaxKey up to 3.5.13. Affected by this issue is the function StrUtils.checkSqlInjection of the file StrUtils.java. Performing a manipulation of the argument filtersfields results in sql injection. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in code-projects Employee Management System 1.0. This affects an unknown part of the file 370project/edit.php. This manipulation of the argument ID causes sql injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12.
A flaw has been found in TRENDnet TEW-821DAP up to 1.12B01. The impacted element is the function tools_diagnostic of the file /tmp/diagnostic of the component Firmware Udpate. This manipulation causes os command injection. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor explains: "That firmware version will only work on our hardware version v1.xR. We have already EOL that product 8 years ago and are no longer selling". This vulnerability only affects products that are no longer supported by the maintainer.
A weakness has been identified in Wavlink NU516U1 240425. This issue affects the function wzdapMesh of the file /cgi-bin/adm.cgi. This manipulation causes os command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure.
A vulnerability was determined in langflow-ai langflow up to 1.8.4. Affected by this issue is the function CodeParser.parse_callable_details of the file src/lfx/src/lfx/custom/code_parser/code_parser.py of the component Full Builtins Module Handler. Executing a manipulation can lead to command injection. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
A security flaw has been discovered in TimBroddin astro-mcp-server up to 1.1.1. The impacted element is an unknown function of the file src/index.ts of the component MCP Tool Query Construction. Performing a manipulation of the argument request.params.arguments results in sql injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. The project was informed of the problem early through an issue report but has not responded yet.
A security flaw has been discovered in Industrial Application Software IAS Canias ERP 8.03. Impacted is the function Runtime.getRuntime.exec of the component RMI Interface. Performing a manipulation of the argument troiaCode results in os command injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
A flaw has been found in ArtMin96 yii2-mcp-server 1.0.2. This impacts the function yii_command_help/yii_execute_command of the file src/index.ts of the component MCP Interface. Executing a manipulation can lead to os command injection. The attack can be executed remotely. The exploit has been published and may be used. The project was informed of the problem early through an issue report but has not responded yet.
A vulnerability was identified in Totolink WA300 5.2cu.7112_B20190227. Impacted is the function setWebWlanIdx of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. The manipulation of the argument webWlanIdx leads to command injection. The attack may be initiated remotely. The exploit is publicly available and might be used.
A security vulnerability has been detected in D-Link DIR-816 1.10CNB05_R1B011D88210. Affected by this issue is the function sub_445E7C of the file /goform/singlePortForward. Such manipulation of the argument ip_address leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used.
A vulnerability was found in code-projects Gym Management System In PHP and Windows NT 1.0. This vulnerability affects unknown code of the file /index.php. Performing a manipulation of the argument day results in sql injection. The attack can be initiated remotely. The exploit has been made public and could be used.
A vulnerability was detected in CodeAstro Online Classroom 1.0. Impacted is an unknown function of the file /OnlineClassroom/studentlogin. Performing a manipulation of the argument sid results in sql injection. Remote exploitation of the attack is possible. The exploit is now public and may be used.
A security vulnerability has been detected in Totolink WA300 5.2cu.7112_B20190227. This affects the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi. Such manipulation of the argument hostTime leads to command injection. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
A vulnerability was detected in code-projects Simple Chat System 1.0. This vulnerability affects unknown code of the file sendMessage.php. The manipulation of the argument type/length/business parameter validity results in sql injection. The attack may be launched remotely. The exploit is now public and may be used.
A vulnerability has been found in SourceCodester Pharmacy Sales and Inventory System 1.0. This impacts the function delete_supplier of the file /ajax.php?action=delete_supplier. Such manipulation of the argument ID leads to sql injection. The attack can be executed remotely. The exploit has been disclosed to the public and may be used.