Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2017-6184

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-30 Mar, 2017 | 17:00
Updated At-05 Aug, 2024 | 15:25
Rejected At-
Credits

In Sophos Web Appliance (SWA) before 4.3.1.2, a section of the machine's interface responsible for generating reports was vulnerable to remote command injection via the token parameter, aka NSWA-1303.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:30 Mar, 2017 | 17:00
Updated At:05 Aug, 2024 | 15:25
Rejected At:
▼CVE Numbering Authority (CNA)

In Sophos Web Appliance (SWA) before 4.3.1.2, a section of the machine's interface responsible for generating reports was vulnerable to remote command injection via the token parameter, aka NSWA-1303.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
x_refsource_CONFIRM
http://www.securityfocus.com/bid/97261
vdb-entry
x_refsource_BID
https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
x_refsource_CONFIRM
Hyperlink: http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
Resource:
x_refsource_CONFIRM
Hyperlink: http://www.securityfocus.com/bid/97261
Resource:
vdb-entry
x_refsource_BID
Hyperlink: https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
x_refsource_CONFIRM
x_transferred
http://www.securityfocus.com/bid/97261
vdb-entry
x_refsource_BID
x_transferred
https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
x_refsource_CONFIRM
x_transferred
Hyperlink: http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
Resource:
x_refsource_CONFIRM
x_transferred
Hyperlink: http://www.securityfocus.com/bid/97261
Resource:
vdb-entry
x_refsource_BID
x_transferred
Hyperlink: https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:30 Mar, 2017 | 17:59
Updated At:20 Apr, 2025 | 01:37

In Sophos Web Appliance (SWA) before 4.3.1.2, a section of the machine's interface responsible for generating reports was vulnerable to remote command injection via the token parameter, aka NSWA-1303.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.04.7MEDIUM
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.0
Base score: 4.7
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

Sophos Ltd.
sophos
>>web_appliance>>Versions up to 4.3.1.1(inclusive)
cpe:2.3:a:sophos:web_appliance:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.htmlcve@mitre.org
Release Notes
Vendor Advisory
http://www.securityfocus.com/bid/97261cve@mitre.org
N/A
https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2cve@mitre.org
Vendor Advisory
http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.htmlaf854a3a-2127-422b-91ae-364da2661108
Release Notes
Vendor Advisory
http://www.securityfocus.com/bid/97261af854a3a-2127-422b-91ae-364da2661108
N/A
https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
Hyperlink: http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
Source: cve@mitre.org
Resource:
Release Notes
Vendor Advisory
Hyperlink: http://www.securityfocus.com/bid/97261
Source: cve@mitre.org
Resource: N/A
Hyperlink: https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
Source: cve@mitre.org
Resource:
Vendor Advisory
Hyperlink: http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Release Notes
Vendor Advisory
Hyperlink: http://www.securityfocus.com/bid/97261
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

457Records found

CVE-2017-6183
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-3.04% / 86.41%
||
7 Day CHG~0.00%
Published-30 Mar, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Sophos Web Appliance (SWA) before 4.3.1.2, a section of the machine's configuration utilities for adding (and detecting) Active Directory servers was vulnerable to remote command injection, aka NSWA-1314.

Action-Not Available
Vendor-n/aSophos Ltd.
Product-web_appliancen/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-0386
Matching Score-8
Assigner-Sophos Limited
ShareView Details
Matching Score-8
Assigner-Sophos Limited
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.55%
||
7 Day CHG~0.00%
Published-21 Mar, 2022 | 23:45
Updated-02 Aug, 2024 | 23:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A post-auth SQL injection vulnerability in the Mail Manager potentially allows an authenticated attacker to execute code in Sophos UTM before version 9.710.

Action-Not Available
Vendor-Sophos Ltd.
Product-unified_threat_managementSophos UTM
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2020-17352
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.23% / 84.24%
||
7 Day CHG~0.00%
Published-07 Aug, 2020 | 19:50
Updated-04 Aug, 2024 | 13:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Two OS command injection vulnerabilities in the User Portal of Sophos XG Firewall through 2020-08-05 potentially allow an authenticated attacker to remotely execute arbitrary code.

Action-Not Available
Vendor-n/aSophos Ltd.
Product-xg_firewall_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-36807
Matching Score-8
Assigner-Sophos Limited
ShareView Details
Matching Score-8
Assigner-Sophos Limited
CVSS Score-8.8||HIGH
EPSS-0.21% / 42.52%
||
7 Day CHG~0.00%
Published-26 Nov, 2021 | 14:12
Updated-04 Aug, 2024 | 01:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authenticated user could potentially execute code via an SQLi vulnerability in the user portal of SG UTM before version 9.708 MR8.

Action-Not Available
Vendor-Sophos Ltd.
Product-unified_threat_management_up2dateSG UTM
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2020-10947
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.46%
||
7 Day CHG~0.00%
Published-17 Apr, 2020 | 12:38
Updated-04 Aug, 2024 | 11:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Mac Endpoint for Sophos Central before 9.9.6 and Mac Endpoint for Sophos Home before 2.2.6 allow Privilege Escalation.

Action-Not Available
Vendor-n/aSophos Ltd.
Product-anti-virus_for_sophos_homeanti-virus_for_sophos_centraln/a
CWE ID-CWE-59
Improper Link Resolution Before File Access ('Link Following')
CVE-2018-16116
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.25%
||
7 Day CHG~0.00%
Published-20 Jun, 2019 | 16:18
Updated-05 Aug, 2024 | 10:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SQL injection vulnerability in AccountStatus.jsp in Admin Portal of Sophos XG firewall 17.0.8 MR-8 allow remote authenticated attackers to execute arbitrary SQL commands via the "username" GET parameter.

Action-Not Available
Vendor-n/aSophos Ltd.
Product-xg_firewallsfosn/a
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-1671
Matching Score-6
Assigner-Sophos Limited
ShareView Details
Matching Score-6
Assigner-Sophos Limited
CVSS Score-9.8||CRITICAL
EPSS-94.30% / 99.94%
||
7 Day CHG~0.00%
Published-04 Apr, 2023 | 00:00
Updated-27 Oct, 2025 | 17:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2023-12-07||Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

A pre-auth command injection vulnerability in the warn-proceed handler of Sophos Web Appliance older than version 4.3.10.4 allows execution of arbitrary code.

Action-Not Available
Vendor-Sophos Ltd.
Product-web_applianceSophos Web ApplianceWeb Appliance
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-4934
Matching Score-6
Assigner-Sophos Limited
ShareView Details
Matching Score-6
Assigner-Sophos Limited
CVSS Score-7.2||HIGH
EPSS-0.20% / 41.84%
||
7 Day CHG~0.00%
Published-04 Apr, 2023 | 00:00
Updated-11 Feb, 2025 | 14:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A post-auth command injection vulnerability in the exception wizard of Sophos Web Appliance older than version 4.3.10.4 allows administrators to execute arbitrary code.

Action-Not Available
Vendor-Sophos Ltd.
Product-web_applianceSophos Web Appliance
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-9554
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-11.27% / 93.37%
||
7 Day CHG~0.00%
Published-28 Jan, 2017 | 12:38
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Sophos Web Appliance Remote / Secure Web Gateway server (version 4.2.1.3) is vulnerable to a Remote Command Injection vulnerability in its web administrative interface. These vulnerabilities occur in MgrDiagnosticTools.php (/controllers/MgrDiagnosticTools.php), in the component responsible for performing diagnostic tests with the UNIX wget utility. The application doesn't properly escape the information passed in the 'url' variable before calling the executeCommand class function ($this->dtObj->executeCommand). This function calls exec() with unsanitized user input allowing for remote command injection. The page that contains the vulnerabilities, /controllers/MgrDiagnosticTools.php, is accessed by a built-in command answered by the administrative interface. The command that calls to that vulnerable page (passed in the 'section' parameter) is: 'configuration'. Exploitation of this vulnerability yields shell access to the remote machine under the 'spiderman' user account.

Action-Not Available
Vendor-n/aSophos Ltd.
Product-web_appliancen/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-9553
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-6.75% / 91.11%
||
7 Day CHG~0.00%
Published-28 Jan, 2017 | 12:38
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Sophos Web Appliance (version 4.2.1.3) is vulnerable to two Remote Command Injection vulnerabilities affecting its web administrative interface. These vulnerabilities occur in the MgrReport.php (/controllers/MgrReport.php) component responsible for blocking and unblocking IP addresses from accessing the device. The device doesn't properly escape the information passed in the variables 'unblockip' and 'blockip' before calling the shell_exec() function which allows for system commands to be injected into the device. The code erroneously suggests that the information handled is protected by utilizing the variable name 'escapedips' - however this was not the case. The Sophos ID is NSWA-1258.

Action-Not Available
Vendor-n/aSophos Ltd.
Product-web_appliancen/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-6327
Matching Score-4
Assigner-Symantec - A Division of Broadcom
ShareView Details
Matching Score-4
Assigner-Symantec - A Division of Broadcom
CVSS Score-8.8||HIGH
EPSS-76.82% / 98.92%
||
7 Day CHG-0.51%
Published-11 Aug, 2017 | 20:00
Updated-22 Oct, 2025 | 00:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-03||Apply updates per vendor instructions.

The Symantec Messaging Gateway before 10.6.3-267 can encounter an issue of remote code execution, which describes a situation whereby an individual may obtain the ability to execute commands remotely on a target machine or in a target process. In this type of occurrence, after gaining access to the system, the attacker may attempt to elevate their privileges.

Action-Not Available
Vendor-Symantec Corporation
Product-message_gatewayMessaging GatewaySymantec Messaging Gateway
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-3065
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-Not Assigned
Published-24 Feb, 2026 | 02:32
Updated-24 Feb, 2026 | 03:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
HummerRisk Cloud Task Dry-run CloudTaskService.java CommandUtils.commonExecCmdWithResult command injection

A vulnerability was detected in HummerRisk up to 1.5.0. This affects the function CommandUtils.commonExecCmdWithResult of the file CloudTaskService.java of the component Cloud Task Dry-run. Performing a manipulation of the argument fileName results in command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-n/a
Product-HummerRisk
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2528
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.38% / 59.16%
||
7 Day CHG-0.46%
Published-16 Feb, 2026 | 02:02
Updated-23 Feb, 2026 | 10:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN579A3 wireless.cgi Delete_Mac_list command injection

A vulnerability was identified in Wavlink WL-WN579A3 up to 20210219. Affected by this vulnerability is the function Delete_Mac_list of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn579a3_firmwarewl-wn579a3WL-WN579A3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-3066
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-Not Assigned
Published-24 Feb, 2026 | 03:02
Updated-24 Feb, 2026 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
HummerRisk Cloud Compliance Scanning PlatformUtils.java fixedCommand command injection

A flaw has been found in HummerRisk up to 1.5.0. This vulnerability affects the function fixedCommand of the file hummer-common/hummer-common-core/src/main/java/com/hummer/common/core/utils/PlatformUtils.java of the component Cloud Compliance Scanning. Executing a manipulation can lead to command injection. The attack can be executed remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-n/a
Product-HummerRisk
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2560
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.34% / 56.67%
||
7 Day CHG~0.00%
Published-16 Feb, 2026 | 14:02
Updated-23 Feb, 2026 | 10:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
kalcaddle kodbox Media File Preview Plugin VideoResize.class.php run os command injection

A vulnerability has been found in kalcaddle kodbox up to 1.64.05. The impacted element is the function run of the file plugins/fileThumb/lib/VideoResize.class.php of the component Media File Preview Plugin. Such manipulation of the argument localFile leads to os command injection. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-kalcaddle
Product-kodbox
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-2530
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.07%
||
7 Day CHG-0.49%
Published-16 Feb, 2026 | 02:32
Updated-23 Feb, 2026 | 10:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN579A3 wireless.cgi AddMac command injection

A weakness has been identified in Wavlink WL-WN579A3 up to 20210219. This affects the function AddMac of the file /cgi-bin/wireless.cgi. This manipulation of the argument macAddr causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn579a3_firmwarewl-wn579a3WL-WN579A3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2535
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.07%
||
7 Day CHG-0.49%
Published-16 Feb, 2026 | 04:32
Updated-23 Feb, 2026 | 10:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 V2 mbox-config sub_44AB9C command injection

A vulnerability was found in Comfast CF-N1 V2 2.6.0.2. The impacted element is the function sub_44AB9C of the file /cgi-bin/mbox-config?method=SET&section=ptest_channel. The manipulation of the argument channel results in command injection. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1cf-n1_firmwareCF-N1 V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2824
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.23% / 45.22%
||
7 Day CHG~0.00%
Published-20 Feb, 2026 | 05:32
Updated-23 Feb, 2026 | 10:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-E7 webmggnt mbox-config sub_441CF4 command injection

A flaw has been found in Comfast CF-E7 2.6.0.9. This affects the function sub_441CF4 of the file /cgi-bin/mbox-config?method=SET&section=ping_config of the component webmggnt. Executing a manipulation of the argument destination can lead to command injection. The attack may be performed from remote. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Comfast
Product-CF-E7
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45557
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.51% / 66.14%
||
7 Day CHG-0.50%
Published-26 Dec, 2021 | 00:50
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GC108P before 1.0.8.2, GC108PP before 1.0.8.2, GS108Tv3 before 7.0.7.2, GS110TPv3 before 7.0.7.2, GS110TPP before 7.0.7.2, GS110TUP before 1.0.5.3, GS710TUP before 1.0.5.3, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS710TUP before 1.0.5.3, GS716TP before 1.0.4.2, GS716TPP before 1.0.4.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS724TPP before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS750E before 1.0.1.10, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-gs710tup_firmwaregs728tppv2gc108p_firmwaregs308tgs310tp_firmwaregs108tv3gs110tpv3_firmwaregs110tupgs110tppgs728tpv2_firmwaregs752tpv2_firmwaregs716tppms510txup_firmwaregs752tppms510txupgs752tpv2gs716tp_firmwarems510txm_firmwarems510txmgs110tpp_firmwaregs728tppv2_firmwaregc108pgs728tpv2gs716tpp_firmwaregs710tupgc108ppgs308t_firmwaregs108tv3_firmwaregs724tpp_firmwaregs110tup_firmwaregs724tppgc108pp_firmwaregs752tpp_firmwaregs750egs724tpv2gs724tpv2_firmwaregs750e_firmwaregs110tpv3gs716tpgs310tpn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45600
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-2.20% / 84.13%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:39
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850cbr750rbs850_firmwarerbr850rbk852rbk852_firmwarecbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45596
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-1.43% / 80.39%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:39
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850rbk752_firmwarerbk752rbs750_firmwarerbr750rbs750cbr750rbs850_firmwarerbr850rbk852_firmwarerbr750_firmwarerbk852cbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45531
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.1||HIGH
EPSS-0.94% / 75.88%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:57
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR D6220 devices before 1.0.0.76 are affected by command injection by an authenticated user.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d6220d6220_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-14586
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.67% / 81.82%
||
7 Day CHG-0.25%
Published-13 Dec, 2025 | 06:32
Updated-24 Feb, 2026 | 05:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X5000R cstecgi.cgi snprintf os command injection

A vulnerability was determined in TOTOLINK X5000R 9.1.0cu.2089_B20211224. Affected by this issue is the function snprintf of the file /cgi-bin/cstecgi.cgi?action=exportOvpn&type=user. This manipulation of the argument User causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-TOTOLINK
Product-x5000r_firmwarex5000rX5000R
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-45541
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-1.88% / 82.88%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:53
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax80rax75r8000r7900r8000prax50rbs850rax45ms60_firmwarerbr750r8000_firmwarer8000p_firmwarerax200r7900prax200_firmwarerbs750_firmwaremr60mr60_firmwarerbs850_firmwarerbr850rax80_firmwarerbr750_firmwarerbk752_firmwarer7900_firmwarerbk752rbs750rax75_firmwarerax50_firmwarerax45_firmwarerbk852_firmwarerbk852r7900p_firmwarems60rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45599
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-0.98% / 76.41%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:39
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850cbr40_firmwarecbr750rbs850_firmwarerbr850rbk852_firmwarerbk852cbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45556
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.79% / 73.56%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:50
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GS108Tv2 before 5.4.2.36, GS110TPP before 7.0.7.2, GS110TPv2 before 5.4.2.36., GS110TPv3 before 7.0.7.2, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-gs728tppv2gs308tgs310tp_firmwaregs308t_firmwaregs110tpv3_firmwaregs110tppgs108tv2_firmwaregs724tpp_firmwaregs728tpv2_firmwaregs752tpv2_firmwarems510txup_firmwaregs110tpv2_firmwaregs752tppms510txupgs108tv2gs752tpv2gs752tpp_firmwarems510txm_firmwaregs724tpv2ms510txmgs724tpv2_firmwaregs110tpv2gs110tpp_firmwaregs110tpv3gs728tppv2_firmwaregs724tppgs728tpv2gs310tpn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45552
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-0.19% / 40.42%
||
7 Day CHG+0.01%
Published-26 Dec, 2021 | 00:51
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.58, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.108, and XR700 before 1.0.1.20.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r7500v2d7800_firmwarer7800r8900r9000_firmwarerax120_firmwarer8900_firmwarer7800_firmwarer7500v2_firmwared7800xr700_firmwarerax120r9000xr700n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45595
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.6||HIGH
EPSS-0.24% / 46.62%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:41
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects LBR20 before 2.6.3.50, RBS50Y before 2.7.3.22, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs40rbs50y_firmwarerbk12rbs40_firmwarerbk20rbr10_firmwarerbr10rbs10_firmwarerbr40_firmwarerbs20_firmwarerbs50_firmwarerbs20rbr40rbs50yrbs50rbr50_firmwarerbk40rbr20rbr50lbr20rbs10rbr20_firmwarerbk50rbk40_firmwarelbr20_firmwarerbk50_firmwarerbk20_firmwarerbk12_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45551
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.6||HIGH
EPSS-2.22% / 84.22%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:51
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6200 before 1.1.00.40, D7000 before 1.0.1.78, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.26, JR6150 before 1.0.1.26, R6120 before 1.0.0.66, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.64, R6800 before 1.2.0.62, R6700v2 before 1.2.0.62, R6900v2 before 1.2.0.62, R7450 before 1.2.0.62, AC2100 before 1.2.0.62, AC2400 before 1.2.0.62, AC2600 before 1.2.0.62, and WNR2020 before 1.1.0.62.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r6700v2_firmwarewnr2020_firmwarer6120r7450_firmwarewnr2020r6220_firmwareac2600r6080_firmwareac2400r6900v2r6120_firmwarer6800r6900v2_firmwarer6050r6260_firmwarer6260r6220r6020ac2400_firmwarer6020_firmwared7000r6080d7000_firmwarer6230r6230_firmwareac2100_firmwared6200_firmwarer6050_firmwarer6700v2ac2100r7450d6200jr6150_firmwarejr6150r6800_firmwareac2600_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45546
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-1.43% / 80.39%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:52
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax200_firmwarerax80r7900p_firmwarerbs750_firmwarer7850_firmwarerbr850_firmwarerbs850_firmwarer8000rax75rbr850rax80_firmwarerbr750_firmwarer8000prbs850rbk752_firmwarer7960prbk752rbr750r8000p_firmwarerbs750r7960p_firmwarer7850rax200rax75_firmwarerbk852_firmwarerbk852r7900pr8000_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45534
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-1.27% / 79.18%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:55
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects AC2100 before 1.2.0.88, AC2400 before 1.2.0.88, AC2600 before 1.2.0.88, D7000 before 1.0.1.82, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.84, R6330 before 1.1.0.84, R6350 before 1.1.0.84, R6700v2 before 1.2.0.88, R6800 before 1.2.0.88, R6850 before 1.1.0.84, R6900v2 before 1.2.0.88, R7200 before 1.2.0.88, R7350 before 1.2.0.88, R7400 before 1.2.0.88, and R7450 before 1.2.0.88.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r6700v2_firmwarer6850_firmwarer7450_firmwarer6220_firmwareac2600ac2400r6900v2r7200_firmwarer6800r6900v2_firmwarer6260_firmwarer6260r6220r6330_firmwareac2400_firmwarer7350_firmwarer7400_firmwarer7200r6350_firmwared7000d7000_firmwarer6230r6330r6230_firmwareac2100_firmwarer7400ac2100r6700v2r6850r6350r7350r7450r6800_firmwareac2600_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2526
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.07%
||
7 Day CHG-0.49%
Published-16 Feb, 2026 | 01:02
Updated-23 Feb, 2026 | 10:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN579A3 wireless.cgi multi_ssid command injection

A vulnerability was found in Wavlink WL-WN579A3 up to 20210219. This impacts the function multi_ssid of the file /cgi-bin/wireless.cgi. Performing a manipulation of the argument SSID2G2 results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn579a3_firmwarewl-wn579a3WL-WN579A3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45548
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-0.82% / 74.03%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:52
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wn3000rpv2rbk20ex6400_firmwareex6150v2_firmwareex7300_firmwarer8900_firmwarerbr40_firmwarerbs20_firmwared7800ex6150v2dm200_firmwarerbk20_firmwarerbk40ex7320_firmwareex6410ex6420_firmwarerbr20wn3000rpv3ex7300v2_firmwarewnr2000v5_firmwareex6250_firmwarexr500_firmwarer7500v2_firmwarerbk40_firmwarerax120ex6400v2_firmwarexr500ex7300ex6420ex7300v2rbs40d7800_firmwaredm200r8900ex6250r9000_firmwarewn3000rpv3_firmwarerbs40_firmwarewn3000rpv2_firmwareex6410_firmwarerbs20ex2700rbr40r9000ex6200v2_firmwareex6400v2r7500v2r7800rax120_firmwareex2700_firmwarerbr20_firmwareex7320r7800_firmwareex6400ex6200v2n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45553
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.7||HIGH
EPSS-1.16% / 78.29%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:51
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7000 before 1.0.11.126, R6900P before 1.3.2.126, and R7000P before 1.3.2.126.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r7000_firmwarer7000p_firmwarer7000r6900pr7000pr6900p_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45601
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-1.43% / 80.39%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:38
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850cbr40_firmwarecbr750rbs850_firmwarerbr850rbk852_firmwarerbk852cbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45555
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-0.27% / 50.60%
||
7 Day CHG+0.01%
Published-26 Dec, 2021 | 00:51
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900P before 1.4.2.84, R7960P before 1.4.2.84, and R8000P before 1.4.2.84.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r7960pr8000p_firmwarer7960p_firmwarer7900pr8000pr7900p_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45598
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-0.98% / 76.41%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:39
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850cbr40_firmwarecbr750rbs850_firmwarerbr850rbk852_firmwarerbk852cbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-44051
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-1.16% / 78.23%
||
7 Day CHG~0.00%
Published-05 May, 2022 | 16:50
Updated-16 Sep, 2024 | 17:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command injection

A command injection vulnerability has been reported to affect QNAP NAS running QuTScloud, QuTS hero and QTS. If exploited, this vulnerability allows remote attackers to run arbitrary commands. We have already fixed this vulnerability in the following versions of QuTScloud, QuTS hero and QTS: QuTScloud c5.0.1.1949 and later QuTS hero h5.0.0.1986 build 20220324 and later QTS 5.0.0.1986 build 20220324 and later

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-quts_heroqutscloudqtsQuTScloudQuTS heroQTS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2956
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.84% / 74.40%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 22:02
Updated-23 Feb, 2026 | 19:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
qinming99 dst-admin restore revertBackup command injection

A security flaw has been discovered in qinming99 dst-admin up to 1.5.0. This affects the function revertBackup of the file /home/restore. The manipulation of the argument Name results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-qinming99
Product-dst-admin
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2548
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.41% / 80.23%
||
7 Day CHG+0.57%
Published-16 Feb, 2026 | 09:02
Updated-23 Feb, 2026 | 10:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WAYOS FBM-220G rc sub_40F820 command injection

A flaw has been found in WAYOS FBM-220G 24.10.19. This affects the function sub_40F820 of the file rc. Executing a manipulation of the argument upnp_waniface/upnp_ssdp_interval/upnp_max_age can lead to command injection. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAYOS
Product-FBM-220G
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-43339
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-12.68% / 93.83%
||
7 Day CHG~0.00%
Published-03 Nov, 2021 | 19:38
Updated-04 Aug, 2024 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Ericsson Network Location before 2021-07-31, it is possible for an authenticated attacker to inject commands via file_name in the export functionality. For example, a new admin user could be created.

Action-Not Available
Vendor-n/aEricsson
Product-network_locationn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2529
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.38% / 59.16%
||
7 Day CHG-0.46%
Published-16 Feb, 2026 | 02:02
Updated-23 Feb, 2026 | 10:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN579A3 wireless.cgi DeleteMac command injection

A security flaw has been discovered in Wavlink WL-WN579A3 up to 20210219. Affected by this issue is the function DeleteMac of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list results in command injection. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn579a3_firmwarewl-wn579a3WL-WN579A3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11523
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.03% / 76.99%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 01:02
Updated-24 Feb, 2026 | 06:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 AdvSetLanip command injection

A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11292
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.16%
||
7 Day CHG~0.00%
Published-05 Oct, 2025 | 14:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1015 formBSSetSitesurvey command injection

A weakness has been identified in Belkin F9K1015 1.00.10. Affected is an unknown function of the file /goform/formBSSetSitesurvey. Executing a manipulation of the argument wan_ipaddr can lead to command injection. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1015_firmwaref9k1015F9K1015
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11298
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.16%
||
7 Day CHG~0.00%
Published-05 Oct, 2025 | 18:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1015 formSetWanStatic command injection

A vulnerability was determined in Belkin F9K1015 1.00.10. Impacted is an unknown function of the file /goform/formSetWanStatic. Executing a manipulation of the argument m_wan_ipaddr can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1015_firmwaref9k1015F9K1015
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11303
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.16%
||
7 Day CHG~0.00%
Published-05 Oct, 2025 | 20:32
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1015 mp command injection

A vulnerability was detected in Belkin F9K1015 1.00.10. Affected is an unknown function of the file /goform/mp. Performing a manipulation of the argument command results in command injection. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1015_firmwaref9k1015F9K1015
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-43469
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-9.40% / 92.63%
||
7 Day CHG~0.00%
Published-06 Dec, 2021 | 11:48
Updated-04 Aug, 2024 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VINGA WR-N300U 77.102.1.4853 is affected by a command execution vulnerability in the goahead component.

Action-Not Available
Vendor-vingan/a
Product-wr-n300u_firmwarewr-n300un/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2527
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.38% / 59.16%
||
7 Day CHG-0.46%
Published-16 Feb, 2026 | 01:32
Updated-23 Feb, 2026 | 10:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN579A3 login.cgi command injection

A vulnerability was determined in Wavlink WL-WN579A3 up to 20210219. Affected is an unknown function of the file /cgi-bin/login.cgi. Executing a manipulation of the argument key can lead to command injection. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn579a3_firmwarewl-wn579a3WL-WN579A3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2534
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.07%
||
7 Day CHG-0.49%
Published-16 Feb, 2026 | 04:02
Updated-23 Feb, 2026 | 10:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 V2 mbox-config sub_44AC4C command injection

A vulnerability has been found in Comfast CF-N1 V2 2.6.0.2. The affected element is the function sub_44AC4C of the file /cgi-bin/mbox-config?method=SET&section=ptest_bandwidth. The manipulation of the argument bandwidth leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1cf-n1_firmwareCF-N1 V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-43160
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.54% / 85.19%
||
7 Day CHG~0.00%
Published-04 May, 2022 | 00:08
Updated-04 Aug, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the switchFastDhcp function in /cgi-bin/luci/api/diagnose.

Action-Not Available
Vendor-n/aRuijie Networks Co., Ltd.
Product-rg-ew300_prorg-ew1200g_prorg-ew1800gx_prorg-ew3200gx_proreyeeosrg-ew1200n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 9
  • 10
  • Next
Details not found