An information exposure of confidential information results when the device receives a specially crafted CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP. Successful exploitation of this vulnerability could cause loss of confidentiality. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
The web interface in the Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge Module allows remote attackers to obtain "internal web page information" and "internal information about the module" via unspecified vectors. NOTE: this may overlap CVE-2002-1603.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR).
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code.
A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed.
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Requests a specific set of bytes from an undocumented data file and returns the ASCII version of the master password.
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Reads the encoded ladder logic from its data file and print it out in HEX.
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. User credentials are sent to the web server in clear text, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server.
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable.
SQL injection vulnerability in Rockwell Automation FactoryTalk EnergyMetrix before 2.20.00 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services.
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix.
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Codes: 0023, 002e, and 0037 Fault Type: Recoverable Description: The STI, EII, and HSC function files contain bits signifying whether or not a fault has occurred. Additionally there is a bit signaling the module to auto start. When these bits are set for any of the three modules and the device is moved into a run state, a fault is triggered.
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0028 Fault Type: Non-User Description: Values 0x01 and 0x02 are invalid values for the user fault routine. By writing directly to the file it is possible to set these values. When this is done and the device is moved into a run state, a fault is triggered. NOTE: This is not possible through RSLogix.
Stack-based buffer overflow on Rockwell Automation Allen-Bradley MicroLogix 1100 devices A through 15.000 and B before 15.002 allows remote attackers to execute arbitrary code via a crafted web request.
Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control.
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords.
An exploitable file write vulnerability exists in the memory module functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a file write resulting in a new program being written to the memory module. An attacker can send an unauthenticated packet to trigger this vulnerability.
All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this information for reconnaissance efforts. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.
Rockwell Automation Arena Simulation Software versions 16.00.00 and earlier contain an INFORMATION EXPOSURE CWE-200. A maliciously crafted Arena file opened by an unsuspecting user may result in the limited exposure of information related to the targeted workstation.
Rockwell Automation Modbus TCP Server AOI prior to 2.04.00 is vulnerable to an unauthorized user sending a malformed message that could cause the controller to respond with a copy of the most recent response to the last valid request. If exploited, an unauthorized user could read the connected device’s Modbus TCP Server AOI information.
All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use MAC addresses to enumerate potential Cloud IDs. Using this ID, the attacker can discover and connect to valid devices using one of the supported apps.
IBM QRadar SIEM 7.3 discloses sensitive information to unauthorized users. The information can be used to mount further attacks on the system. IBM X-Force ID: 147708.
Ceph does not properly sanitize encryption keys in debug logging for v4 auth. This results in the leaking of encryption key information in log files via plaintext. Versions up to v13.2.4 are vulnerable.
IBM Maximo Asset Management 7.6 through 7.6.3 could allow an unauthenticated attacker to obtain sensitive information from error messages. IBM X-Force ID: 145967.
IBM Security Guardium 10.5, 10.6, and 11.1 could disclose sensitive information on the login page that could aid in further attacks against the system. IBM X-Force ID: 174804.
An issue was discovered in CIRCONTROL CirCarLife before 4.3. There is system software information disclosure due to lack of authentication for /html/device-id.
IBM QRadar Advisor with Watson 1.14.0 discloses sensitive information to unauthorized users. The information can be used to mount further attacks on the system. IBM X-Force ID: 147810.
An issue was discovered in Oracle WebCenter Interaction Portal 10.3.3. The portal component is delivered with an insecure default User Profile community configuration that allows anonymous users to retrieve the account names of all portal users via /portal/server.pt/user/user/ requests. When WCI is synchronised with Active Directory (AD), this vulnerability can expose the account names of all AD users. NOTE: this CVE is assigned by MITRE and isn't validated by Oracle because Oracle WebCenter Interaction Portal is out of support.
IBM MobileFirst Platform Foundation 8.0.0.0 stores highly sensitive information in URL parameters. This may lead to information disclosure if unauthorized parties have access to the URLs via server logs, referrer header or browser history. IBM X-Force ID: 175207.
FURUNO FELCOM 250 and 500 devices allow unauthenticated access to the xml/permission.xml file containing all of the system's usernames and passwords. This includes the Admin and Service user accounts and their unsalted MD5 hashes, as well as the SMS server password in cleartext.
Guzzle is an open source PHP HTTP client. In affected versions the `Cookie` headers on requests are sensitive information. On making a request using the `https` scheme to a server which responds with a redirect to a URI with the `http` scheme, or on making a request to a server which responds with a redirect to a a URI to a different host, we should not forward the `Cookie` header on. Prior to this fix, only cookies that were managed by our cookie middleware would be safely removed, and any `Cookie` header manually added to the initial request would not be stripped. We now always strip it, and allow the cookie middleware to re-add any cookies that it deems should be there. Affected Guzzle 7 users should upgrade to Guzzle 7.4.4 as soon as possible. Affected users using any earlier series of Guzzle should upgrade to Guzzle 6.5.7 or 7.4.4. Users unable to upgrade may consider an alternative approach to use your own redirect middleware, rather than ours. If you do not require or expect redirects to be followed, one should simply disable redirects all together.
Lexiglot through 2014-11-20 allows remote attackers to obtain sensitive information (names and details of projects) by visiting the /update.log URI.
A vulnerability was found in Intelbras VIP S3020 G2, VIP S4020 G2, VIP S4020 G3 and VIP S4320 G2 up to 20241222 and classified as problematic. Affected by this issue is some unknown functionality of the file /web_caps/webCapsConfig of the component Web Interface. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor assesses that "the information disclosed in the URL is not sensitive or poses any risk to the user".
IBM Security Guardium Insights 2.0.1 stores sensitive information in URL parameters. This may lead to information disclosure if unauthorized parties have access to the URLs via server logs, referrer header or browser history. IBM X-Force ID: 174408.
The Open Atrium Core module for Drupal before 7.x-2.22 allows remote attackers to bypass access restrictions and read file attachments that have been removed from a node by leveraging a previous revision of the node.
IBM QRadar Network Security 5.4.0 and 5.5.0 discloses sensitive information to unauthorized users which could be used to mount further attacks against the system. IBM X-Force ID: 174339.
A vulnerability classified as problematic has been found in Amcrest IP2M-841B, IP2M-841W, IPC-IP2M-841B, IPC-IP3M-943B, IPC-IP3M-943S, IPC-IP3M-HX2B and IPC-IPM-721S up to 20241211. This affects an unknown part of the file /web_caps/webCapsConfig of the component Web Interface. The manipulation leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
IBM Tivoli Key Lifecycle Manager 2.6, 2.7, and 3.0 discloses sensitive information to unauthorized users. The information can be used to mount further attacks on the system. IBM X-Force ID: 148422.
A vulnerability in live_check.shtml of WAVLINK AERIAL X 1200M M79X3.V5030.180719 allows attackers to obtain sensitive router information via execution of the exec cmd function.
SSB-DB version 20.0.0 has an information disclosure vulnerability. The get() method is supposed to only decrypt messages when you explicitly ask it to, but there is a bug where it's decrypting any message that it can. This means that it is returning the decrypted content of private messages, which a malicious peer could use to get access to private data. This only affects peers running SSB-DB@20.0.0 who also have private messages, and is only known to be exploitable if you're also running SSB-OOO (default in SSB-Server), which exposes a thin wrapper around get() to anonymous peers. This is fixed in version 20.0.1. Note that users of SSB-Server verion 16.0.0 should upgrade to 16.0.1 to get the fixed version of SSB-DB.
IBM Watson Studio Local 1.2.3 could disclose sensitive information over the network that an attacked could use in further attacks against the system. IBM X-Force ID: 145238.
A vulnerability was found in Jspxcms 10.2.0 and classified as problematic. Affected by this issue is some unknown functionality of the file /template/1/default/. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-252698 is the identifier assigned to this vulnerability.
PEEL, possibly 3.x and earlier, allows remote attackers to obtain configuration information via a direct request to phpinfo.php, which calls the phpinfo function.
IBM Sterling B2B Integrator Standard Edition 5.2 through 5.2.6 could allow an unauthenticated user to obtain sensitive information that could be used in further attacks against the system. IBM X-Force ID: 145180.
Improper privilege management vulnerability in Samsung Account prior to 13.2.00.6 allows attackers to get the data of contact and gallery without permission.