A hard-coded password vulnerability was discovered in vApp Manager which is embedded in Dell EMC Unisphere for VMAX, Dell EMC Solutions Enabler, Dell EMC VASA Virtual Appliances, and Dell EMC VMAX Embedded Management (eManagement): Dell EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.18, Dell EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.21, Dell EMC VASA Virtual Appliance versions prior to 8.4.0.514, and Dell EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier). They contain an undocumented default account (smc) with a hard-coded password that may be used with certain web servlets. A remote attacker with the knowledge of the hard-coded password and the message format may use vulnerable servlets to gain unauthorized access to the system. Note: This account cannot be used to log in via the web user interface.
Use of a Hard-coded Cryptographic Key used to protect cookie session data in /var/www/xms/application/config/config.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to bypass authentication.
ASUSTOR ADM 3.1.0.RFQ3 uses the same default root:admin username and password as it does for the NAS itself for applications that are installed from the online repository. This may allow an attacker to login and upload a webshell.
An issue was discovered on Intelbras NCLOUD 300 1.0 devices. /cgi-bin/ExportSettings.sh, /goform/updateWPS, /goform/RebootSystem, and /goform/vpnBasicSettings do not require authentication. For example, when an HTTP POST request is made to /cgi-bin/ExportSettings.sh, the username, password, and other details are retrieved.
Emerson DeltaV Smart Switch Command Center application, available in versions 11.3.x and 12.3.1, was unable to change the DeltaV Smart Switches’ management password upon commissioning. Emerson released patches for DeltaV workstations to address this issue, and the patches can be downloaded from Emerson’s Guardian Support Portal. Please refer to the DeltaV Security Notification DSN19003 (KBA NK-1900-0808) for more information about this issue. DeltaV versions 13.3 and higher use the Network Device Command Center application to manage DeltaV Smart Switches, and this newer application is not impacted by this issue. After patching the Smart Switch Command Center, users are required to either commission the DeltaV Smart Switches or change password using the tool.
/usr/lib/lua/luci/websys.lua on TP-LINK IPC TL-IPC223(P)-6, TL-IPC323K-D, TL-IPC325(KP)-*, and TL-IPC40A-4 devices has a hardcoded zMiVw8Kw0oxKXL0 password.
Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Directus 6.4.9 has a hardcoded admin password for the Admin account because of an INSERT statement in api/schema.sql.
Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Use of Hard-coded Credentials in /var/www/xms/application/controllers/gatherLogs.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to interact with a web service.
Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100 utilizes hard-coded credentials that may allow an attacker to reset passwords for the controller.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A hard-coded account allows management-interface login with high privileges. The logged-in user can perform critical tasks and take full control of the device.
NUUO NVRmini 2 1.0.0 through 3.0.0 and NUUO NVRsolo 1.0.0 through 3.0.0 have hardcoded root credentials, which allows remote attackers to obtain administrative access via unspecified vectors.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
Use of Hard-coded Credentials in the database of Bosch FSM-2500 server and Bosch FSM-5000 server up to and including version 5.2 allows an unauthenticated remote attacker to log into the database with admin-privileges. This may result in complete compromise of the confidentiality and integrity of the stored data as well as a high availability impact on the database itself. In addition, an attacker may execute arbitrary commands on the underlying operating system.
SAP Commerce, versions - 6.7, 1808, 1811, 1905, and SAP Commerce (Data Hub), versions - 6.7, 1808, 1811, 1905, allows an attacker to bypass the authentication and/or authorization that has been configured by the system administrator due to the use of Hardcoded Credentials.
Dell EMC Networking S4100 and S5200 Series Switches manufactured prior to February 2020 contain a hardcoded credential vulnerability. A remote unauthenticated malicious user could exploit this vulnerability and gain administrative privileges.
IBM Security Identity Governance and Intelligence 5.2 through 5.2.4.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153386.
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
IBM Security Guardium 10 and 10.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 150022.
VMware Photos OS OVA 1.0 before 2016-08-14 has a default SSH public key in an authorized_keys file, which allows remote attackers to obtain SSH access by leveraging knowledge of the private key.
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Hardcoded credentials exist for an unprivileged SSH account with a shell of /bin/false.
The firmware of the PLANET Technology Corp NVR-915 and NVR-1615 before 2020-10-28 embeds default credentials for root access via telnet. By exposing telnet on the Internet, remote root access on the device is possible. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
Invoxia NVX220 devices allow TELNET access as admin with a default password.
Battelle V2I Hub 2.5.1 contains hard-coded credentials for the administrative account. An attacker could exploit this vulnerability to log in as an admin on any installation and gain unauthorized access to the system.
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
GateManager versions prior to 9.2c, The affected product contains a hard-coded credential for telnet, allowing an unprivileged attacker to execute commands as root.
Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 use hardcoded credentials to access Keystone service. These credentials allow network based attackers unauthorized access to information stored in keystone.
D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 has a default password of root for the root account and tw for the tw account, which makes it easier for remote attackers to obtain administrative access.
A vulnerability in Cisco IOS XE Software could allow an unauthenticated, remote attacker to log in to a device running an affected release of Cisco IOS XE Software with the default username and password that are used at initial boot, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with privilege level 15 that has a default username and password. An attacker could exploit this vulnerability by using this account to remotely connect to an affected device. A successful exploit could allow the attacker to log in to the device with privilege level 15 access. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS XE Software Release 16.x. This vulnerability does not affect Cisco IOS XE Software releases prior to Release 16.x. Cisco Bug IDs: CSCve89880.
EMC Data Protection Advisor 6.3.x before patch 67 and 6.4.x before patch 130 contains undocumented accounts with hard-coded passwords and various privileges. Affected accounts are: "Apollo System Test", "emc.dpa.agent.logon" and "emc.dpa.metrics.logon". An attacker with knowledge of the password could potentially use these accounts via REST APIs to gain unauthorized access to EMC Data Protection Advisor (including potentially access with administrative privileges).
Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices have default credentials that are hardcoded in the firmware and can be extracted by anyone who reverses the firmware to identify them. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable function that sets up the default credentials on the device. If one opens this binary in IDA-pro, one will notice that this follows a ARM little endian format. The function sub_3DB2FC in IDA pro is identified to be setting up the values at address 0x003DB5A6. The sub_5C057C then sets this value and adds it to the Configuration files in /mnt/mtd/Config/Account1 file.
iball Baton 150M iB-WRA150N v1 00000001 1.2.6 build 110401 Rel.47776n devices are prone to an authentication bypass vulnerability that allows remote attackers to view and modify administrative router settings by reading the HTML source code of the password.cgi file.
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.
The Data Warehouse component in NetApp OnCommand Insight before 7.2.3 allows remote attackers to obtain administrative access by leveraging a default privileged account.
EMC ESRS Policy Manager prior to 6.8 contains an undocumented account (OpenDS admin) with a default password. A remote attacker with the knowledge of the default password may login to the system and gain administrator privileges to the local LDAP directory server.
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session.
The Carlo Gavazzi EOS-Box stores hard-coded passwords in the PHP file of the device. By using the hard-coded passwords, attackers can log into the device with administrative privileges. This could allow the attacker to have unauthorized access.
An issue was discovered in Polycom Web Management Interface G3/HDX 8000 HD with Durango 2.6.0 4740 software and embedded Polycom Linux Development Platform 2.14.g3. It has a blank administrative password by default, and can be successfully used without setting this password.
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
man-group/dtale version 3.10.0 is vulnerable to an authentication bypass and remote code execution (RCE) due to improper input validation. The vulnerability arises from a hardcoded `SECRET_KEY` in the flask configuration, allowing attackers to forge a session cookie if authentication is enabled. Additionally, the application fails to properly restrict custom filter queries, enabling attackers to execute arbitrary code on the server by bypassing the restriction on the `/update-settings` endpoint, even when `enable_custom_filters` is not enabled. This vulnerability allows attackers to bypass authentication mechanisms and execute remote code on the server.
The getUserzoneCookie function in Kaltura before 13.2.0 uses a hardcoded cookie secret to validate cookie signatures, which allows remote attackers to bypass an intended protection mechanism and consequently conduct PHP object injection attacks and execute arbitrary PHP code via a crafted userzone cookie.