A hidden backdoor on PATLITE NH-FB Series devices with firmware version 1.45 or earlier, NH-FV Series devices with firmware version 1.10 or earlier, and NBM Series devices with firmware version 1.09 or earlier allow attackers to enable an SSH daemon via the "kankichi" or "kamiyo4" password to the _secret1.htm URI. Subsequently, the default password of root for the root account allows an attacker to conduct remote code execution and as a result take over the system.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The admin account has a blank password.
IBM Security Identity Governance and Intelligence 5.2 through 5.2.4.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153386.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The CGIProxy.fcgi?cmd=setTelnetSwitch feature is authorized for the root user with a password of toor.
spaces.htm on multiple D-Link devices (DSL, DIR, DWR) allows remote unauthenticated attackers to discover admin credentials.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.
Hardcoded credentials in the Ricoh myPrint application 2.9.2.4 for Windows and 2.2.7 for Android give access to any externally disclosed myPrint WSDL API, as demonstrated by discovering API secrets of related Google cloud printers, encrypted passwords of mail servers, and names of printed files.
NUUO CMS all versions 3.1 and prior, The application creates default accounts that have hard-coded passwords, which could allow an attacker to gain privileged access.
IBM Security Guardium 10 and 10.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 150022.
ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session.
Versions of DocuTrac QuicDoc and Office Therapy that ship with DTISQLInstaller.exe version 1.6.4.0 and prior contain three credentials with known passwords: QDMaster, OTMaster, and sa.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it.
POSIM EVO 15.13 for Windows includes hardcoded database credentials for the "root" database user. "root" access to POSIM EVO's database may result in a breach of confidentiality, integrity, or availability or allow for attackers to remotely execute code on associated POSIM EVO clients.
NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers' installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option.
The Fedora Nagios package uses "nagiosadmin" as the default password for the "nagiosadmin" administrator account, which makes it easier for remote attackers to obtain access by leveraging knowledge of the credentials.
Invoxia NVX220 devices allow TELNET access as admin with a default password.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.
A vulnerability in Cisco Video Surveillance Manager (VSM) Software running on certain Cisco Connected Safety and Security Unified Computing System (UCS) platforms could allow an unauthenticated, remote attacker to log in to an affected system by using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, default, static user credentials for the root account of the affected software on certain systems. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
Datto ALTO and SIRIS devices have a default VNC password.
A vulnerability in the install function of Cisco Prime Collaboration Provisioning (PCP) could allow an unauthenticated, remote attacker to access the administrative web interface using a default hard-coded username and password that are used during install. The vulnerability is due to a hard-coded password that, in some cases, is not replaced with a unique password. A successful exploit could allow the attacker to access the administrative web interface with administrator-level privileges.
Logitech Harmony Hub before version 4.15.206 contained two hard-coded accounts in the XMPP server that gave remote users access to the local API.
TimeTools SC7105 1.0.007, SC9205 1.0.007, SC9705 1.0.007, SR7110 1.0.007, SR9210 1.0.007, SR9750 1.0.007, SR9850 1.0.007, T100 1.0.003, T300 1.0.003, and T550 1.0.003 devices allow remote attackers to bypass authentication by placing t3axs=TiMEtOOlsj7G3xMm52wB in a t3.cgi request, aka a "hardcoded cookie."
Deltek Vision 7.x before 7.6 permits the execution of any attacker supplied SQL statement through a custom RPC over HTTP protocol. The Vision system relies on the client binary to enforce security rules and integrity of SQL statements and other content being sent to the server. Client HTTP calls can be manipulated by one of several means to execute arbitrary SQL statements (similar to SQLi) or possibly have unspecified other impact via this custom protocol. To perform these attacks an authenticated session is first required. In some cases client calls are obfuscated by encryption, which can be bypassed due to hard-coded keys and an insecure key rotation protocol. Impacts may include remote code execution in some deployments; however, the vendor states that this cannot occur when the installation documentation is heeded.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Quest Foglight Evolve 9.0.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the __service__ user account. The product contains a hard-coded password for this account. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-9553.
Intellian Aptus Web 1.24 has a hardcoded password of 12345678 for the intellian account.
The Intellian Aptus application 1.0.2 for Android has a hardcoded password of intellian for the masteruser FTP account.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.
Use of Hard-coded Credentials in the database of Bosch FSM-2500 server and Bosch FSM-5000 server up to and including version 5.2 allows an unauthenticated remote attacker to log into the database with admin-privileges. This may result in complete compromise of the confidentiality and integrity of the stored data as well as a high availability impact on the database itself. In addition, an attacker may execute arbitrary commands on the underlying operating system.
EMV DiskXtender 6.20.060 has a hard-coded login and password, which allows remote attackers to bypass authentication via the RPC interface.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
IBM Data Risk Manager 2.0.1, 2.0.2, 2.0.3, 2.0.4, 2.0.5, and 2.0.6 contains a default password for an IDRM administrative account. A remote attacker could exploit this vulnerability to login and execute arbitrary code on the system with root privileges. IBM X-Force ID: 180534.
D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 has a default password of root for the root account and tw for the tw account, which makes it easier for remote attackers to obtain administrative access.
Sollae Serial-Ethernet-Module and Remote-I/O-Device-Server devices have a default password of sollae for the TELNET service.
IBM Spectrum Protect Plus 10.1.0 thorugh 10.1.6 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 190454.
Dell EMC Networking S4100 and S5200 Series Switches manufactured prior to February 2020 contain a hardcoded credential vulnerability. A remote unauthenticated malicious user could exploit this vulnerability and gain administrative privileges.
A hard-coded password vulnerability was discovered in vApp Manager which is embedded in Dell EMC Unisphere for VMAX, Dell EMC Solutions Enabler, Dell EMC VASA Virtual Appliances, and Dell EMC VMAX Embedded Management (eManagement): Dell EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.18, Dell EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.21, Dell EMC VASA Virtual Appliance versions prior to 8.4.0.514, and Dell EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier). They contain an undocumented default account (smc) with a hard-coded password that may be used with certain web servlets. A remote attacker with the knowledge of the hard-coded password and the message format may use vulnerable servlets to gain unauthorized access to the system. Note: This account cannot be used to log in via the web user interface.
The Oracle WebCenter Interaction 10.3.3 search service queryd.exe binary is compiled with the i1g2s3c4 hardcoded password. Authentication to the Oracle WCI search service uses this hardcoded password and cannot be customised by customers. An adversary able to access this service over a network could perform search queries to extract large quantities of sensitive information from the WCI installation. NOTE: this CVE is assigned by MITRE and isn't validated by Oracle because Oracle WebCenter Interaction Portal is out of support.
The MySQL server in Juniper Networks Junos Space before 13.3R1.8 has an unspecified account with a hardcoded password, which allows remote attackers to obtain sensitive information and consequently obtain administrative control by leveraging database access.
SV3C L-SERIES HD CAMERA V2.3.4.2103-S50-NTD-B20170508B and V2.3.4.2103-S50-NTD-B20170823B devices have a Hard-coded Password.
A vulnerability in the Telnet service of Cisco Small Business RV110W Wireless-N VPN Firewall Routers could allow an unauthenticated, remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. An attacker could exploit this vulnerability by using this default account to connect to the affected system. A successful exploit could allow the attacker to gain full control of an affected device.
A vulnerability in the REST API of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. The vulnerability exists because different installations share a static encryption key. An attacker could exploit this vulnerability by using the static key to craft a valid session token. A successful exploit could allow the attacker to perform arbitrary actions through the REST API with administrative privileges.