The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 allows a remote, unauthenticated attacker to enable telnetd on the router via a crafted HTTP request.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered on Shenzhen Coship WM3300 WiFi Router 5.0.0.55 devices. The password reset functionality of the Wireless SSID doesn't require any type of authentication. By making a POST request to the regx/wireless/wl_security_2G.asp URI, the attacker can change the password of the Wi-FI network.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
On Signify Philips Taolight Smart Wi-Fi Wiz Connected LED Bulb 9290022656 devices, an unprotected API lets remote users control the bulb's operation. Anyone can turn the bulb on or off, or change its color or brightness remotely. There is no authentication or encryption to use the control API. The only requirement is that the attacker have network access to the bulb.
Functions/EWD_UFAQ_Import.php in the ultimate-faqs plugin through 1.8.24 for WordPress allows unauthenticated options import.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
The udpServerSys service in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to initiate firmware upgrades and alter device settings.
RouterOS versions 6.45.6 Stable, 6.44.5 Long-term, and below allow remote unauthenticated attackers to trigger DNS queries via port 8291. The queries are sent from the router to a server of the attacker's choice. The DNS responses are cached by the router, potentially resulting in cache poisoning
RedwoodHQ 2.5.5 does not require any authentication for database operations, which allows remote attackers to create admin users via a con.automationframework users insert_one call.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
getgps data in iTrack Easy can be modified without authentication by setting the data using the parametercmd:setothergps. This vulnerability can be exploited to alter the GPS data of a lost device.
A Missing Authentication for Critical Function vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to reconfigure the device from an unknown source because of lack of authentication on proprietary networking commands.
OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000.
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
HPE Data Protector before 7.03_108, 8.x before 8.15, and 9.x before 9.06 allow remote attackers to execute arbitrary code via unspecified vectors related to lack of authentication. NOTE: this vulnerability exists because of an incomplete fix for CVE-2014-2623.
Super Micro SuperDoctor 5, when restrictions are not implemented in agent.cfg, allows remote attackers to execute arbitrary commands via NRPE.
An authentication bypass vulnerability in the CRUDLab WP Like Button plugin through 1.6.0 for WordPress allows unauthenticated attackers to change settings. The contains() function in wp_like_button.php did not check if the current request is made by an authorized user, thus allowing any unauthenticated user to successfully update settings, as demonstrated by the wp-admin/admin.php?page=facebook-like-button each_page_url or code_snippet parameter.
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access.
An issue was discovered in Joomla! before 3.9.5. The "refresh list of helpsites" endpoint of com_users lacks access checks, allowing calls from unauthenticated users.
WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request.
An Incorrect Access Control vulnerability was found in Wikimedia MediaWiki 1.27.0 through 1.32.1. Directly POSTing to Special:ChangeEmail would allow for bypassing re-authentication, allowing for potential account takeover.
A broken access control vulnerability found in Advan VD-1 firmware versions up to 230. An attacker can send a POST request to cgibin/ApkUpload.cgi to install arbitrary APK without any authentication.
Fresenius Kabi Agilia SP MC WiFi vD25 and prior has a default configuration page accessible without authentication. An attacker may use this functionality to change the exposed configuration values such as network settings.
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
An issue was discovered in Zoho ManageEngine Desktop Central 10.0.124 and 10.0.184: insufficient enforcement of database query type restrictions.
An issue was discovered in Emote Remote Mouse through 4.0.0.0. Attackers can maximize or minimize the window of a running process by sending the process name in a crafted packet. This information is sent in cleartext and is not protected by any authentication logic.
On SOYAL AR-727H and AR-829Ev5 devices, all CGI programs allow unauthenticated POST access.
In mintplex-labs/anything-llm v1.5.11 desktop version for Windows, the application opens server port 3001 on 0.0.0.0 with no authentication by default. This vulnerability allows an attacker to gain full backend access, enabling them to perform actions such as deleting all data from the workspace.
The Thrive Optimize WordPress plugin before 1.4.13.3, Thrive Comments WordPress plugin before 1.4.15.3, Thrive Headline Optimizer WordPress plugin before 1.3.7.3, Thrive Leads WordPress plugin before 2.3.9.4, Thrive Ultimatum WordPress plugin before 2.3.9.4, Thrive Quiz Builder WordPress plugin before 2.3.9.4, Thrive Apprentice WordPress plugin before 2.3.9.4, Thrive Visual Editor WordPress plugin before 2.6.7.4, Thrive Dashboard WordPress plugin before 2.3.9.3, Thrive Ovation WordPress plugin before 2.4.5, Thrive Clever Widgets WordPress plugin before 1.57.1 and Rise by Thrive Themes WordPress theme before 2.0.0, Ignition by Thrive Themes WordPress theme before 2.0.0, Luxe by Thrive Themes WordPress theme before 2.0.0, FocusBlog by Thrive Themes WordPress theme before 2.0.0, Minus by Thrive Themes WordPress theme before 2.0.0, Squared by Thrive Themes WordPress theme before 2.0.0, Voice WordPress theme before 2.0.0, Performag by Thrive Themes WordPress theme before 2.0.0, Pressive by Thrive Themes WordPress theme before 2.0.0, Storied by Thrive Themes WordPress theme before 2.0.0, Thrive Themes Builder WordPress theme before 2.2.4 register a REST API endpoint associated with Zapier functionality. While this endpoint was intended to require an API key in order to access, it was possible to access it by supplying an empty api_key parameter in vulnerable versions if Zapier was not enabled. Attackers could use this endpoint to add arbitrary data to a predefined option in the wp_options table.
An issue was discovered in upgrade_firmware.cgi on VStarcam 100T (C7824WIP) CH-sys-48.53.75.119~123 and 200V (C38S) CH-sys-48.53.203.119~123 devices. A remote command can be executed through a system firmware update without authentication. The attacker can modify the files within the internal firmware or even steal account information by executing a command.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.15 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via the user authentication dialogue, aka HMCCU-153. This leads to automatic login as admin.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin.
Under certain circumstances, SAP HANA Extended Application Services, advanced model (XS advanced) does not perform authentication checks properly for XS advanced platform and business users. Fixed in 1.0.97 to 1.0.99 (running on SAP HANA 1 or SAP HANA 2 SPS0 (second S stands for stack)).
SAP Process Integration, business-to-business add-on, versions 1.0, 2.0, does not perform authentication check properly when the default security provider is changed to BouncyCastle (BC), leading to Missing Authentication Check
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
Contec Smart Home 4.15 devices do not require authentication for new_user.php, edit_user.php, delete_user.php, and user.php, as demonstrated by changing the admin password and then obtaining control over doors.
The default configuration in Apache Cassandra 3.8 through 3.11.1 binds an unauthenticated JMX/RMI interface to all network interfaces, which allows remote attackers to execute arbitrary Java code via an RMI request. This issue is a regression of CVE-2015-0225. The regression was introduced in https://issues.apache.org/jira/browse/CASSANDRA-12109. The fix for the regression is implemented in https://issues.apache.org/jira/browse/CASSANDRA-14173. This fix is contained in the 3.11.2 release of Apache Cassandra.
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices.
A missing authentication for appliance registration vulnerability in Trend Micro Email Encryption Gateway 5.5 could allow an attacker to manipulate the registration process of the product to reset configuration parameters.
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device.
The TP-LINK EAP Controller is TP-LINK's software for remotely controlling wireless access point devices. It utilizes a Java remote method invocation (RMI) service for remote control. The RMI interface does not require any authentication before use, so it lacks user authentication for RMI service commands in EAP controller versions 2.5.3 and earlier. Remote attackers can implement deserialization attacks through the RMI protocol. Successful attacks may allow a remote attacker to remotely control the target server and execute Java functions or bytecode.
An issue was discovered in Zoho ManageEngine Desktop Central 10.0.124 and 10.0.184: missing authentication/authorization for a database query mechanism.