An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Insufficient password requirements for the MGate web application may allow an attacker to gain access by brute-forcing account passwords.
Moxa IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior use plaintext transmission of sensitive data, which may allow an attacker to capture sensitive data such as an administrative password.
PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted.
Moxa IKS and EDS generate a predictable cookie calculated with an MD5 hash, allowing an attacker to capture the administrator's password, which could lead to a full compromise of the device.
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
MXsecurity version 1.0 is vulnearble to hardcoded credential vulnerability. This vulnerability has been reported that can be exploited to craft arbitrary JWT tokens and subsequently bypass authentication for web-based APIs.
TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prior are vulnerable to the command injection vulnerability. This vulnerability stems from inadequate input validation in the certificate management function, which could potentially allow malicious users to execute remote code on affected devices.
A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions.
Eaton 9000X DriveA versions 2.0.29 and prior has a stack-based buffer overflow vulnerability, which may allow remote code execution.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code.
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext.
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication.
TN-5900 Series firmware versions v3.3 and prior are vulnerable to command-injection vulnerability. This vulnerability stems from insufficient input validation and improper authentication in the key-generation function, which could potentially allow malicious users to execute remote code on affected devices.
TN-4900 Series firmware versions v1.2.4 and prior and TN-5900 Series firmware versions v3.3 and prior are vulnerable to the command-injection vulnerability. This vulnerability stems from insufficient input validation in the certificate-generation function, which could potentially allow malicious users to execute remote code on affected devices.
Moxa SoftCMS 1.3 and prior is susceptible to a buffer overflow condition that may crash or allow remote code execution. Moxa released SoftCMS version 1.4 on June 1, 2015, to address the vulnerability.
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash.
Two buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O Series firmware version 2.2 or earlier may allow a remote attacker to cause a denial-of-service condition.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, some of the parameters in the setting pages do not ensure text is the correct size for its buffer.
An exploitable format string vulnerability exists in the iw_console conio_writestr functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted time server entry can cause an overflow of the time server buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.
A vulnerability has been identified in the EDR-810, EDR-G902, and EDR-G903 Series, making them vulnerable to the denial-of-service vulnerability. This vulnerability stems from insufficient input validation in the URI, potentially enabling malicious users to trigger the device reboot.
This issue is fixed in SCSSU-201801. A potential stack based buffer overflow existed in GemaltoKeyHandle.cpp.
A buffer overflow vulnerability exists in the GetValue functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted configuration value can lead to a buffer overflow. An attacker can modify a configuration value to trigger this vulnerability.This vulnerability represents all occurances of the buffer overflow vulnerability within the rtk_ate binary.
A vulnerability has been found in Tenda AC8 16.03.34.06. This impacts an unknown function of the file /goform/DatabaseIniSet. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A weakness has been identified in D-Link DWR-M920, DWR-M921, DWR-M960, DIR-822K and DIR-825M 1.01.07. This issue affects some unknown processing of the file /boafrm/formTracerouteDiagnosticRun. Executing manipulation of the argument host can lead to buffer overflow. The attack may be launched remotely. The exploit has been made available to the public and could be exploited.
A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.7), RUGGEDCOM i801 (All versions < V4.3.7), RUGGEDCOM i802 (All versions < V4.3.7), RUGGEDCOM i803 (All versions < V4.3.7), RUGGEDCOM M2100 (All versions < V4.3.7), RUGGEDCOM M2200 (All versions < V4.3.7), RUGGEDCOM M969 (All versions < V4.3.7), RUGGEDCOM RMC30 (All versions < V4.3.7), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM RP110 (All versions < V4.3.7), RUGGEDCOM RS1600 (All versions < V4.3.7), RUGGEDCOM RS1600F (All versions < V4.3.7), RUGGEDCOM RS1600T (All versions < V4.3.7), RUGGEDCOM RS400 (All versions < V4.3.7), RUGGEDCOM RS401 (All versions < V4.3.7), RUGGEDCOM RS416 (All versions < V4.3.7), RUGGEDCOM RS416P (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.5.4), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM RS8000 (All versions < V4.3.7), RUGGEDCOM RS8000A (All versions < V4.3.7), RUGGEDCOM RS8000H (All versions < V4.3.7), RUGGEDCOM RS8000T (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900G (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900GP (All versions < V4.3.7), RUGGEDCOM RS900L (All versions < V4.3.7), RUGGEDCOM RS900W (All versions < V4.3.7), RUGGEDCOM RS910 (All versions < V4.3.7), RUGGEDCOM RS910L (All versions < V4.3.7), RUGGEDCOM RS910W (All versions < V4.3.7), RUGGEDCOM RS920L (All versions < V4.3.7), RUGGEDCOM RS920W (All versions < V4.3.7), RUGGEDCOM RS930L (All versions < V4.3.7), RUGGEDCOM RS930W (All versions < V4.3.7), RUGGEDCOM RS940G (All versions < V4.3.7), RUGGEDCOM RS969 (All versions < V4.3.7), RUGGEDCOM RSG2100 (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100P (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2200 (All versions < V4.3.7), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM RSG907R (All versions < V5.5.4), RUGGEDCOM RSG908C (All versions < V5.5.4), RUGGEDCOM RSG909R (All versions < V5.5.4), RUGGEDCOM RSG910C (All versions < V5.5.4), RUGGEDCOM RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM RSL910 (All versions < V5.5.4), RUGGEDCOM RST2228 (All versions < V5.5.4), RUGGEDCOM RST2228P (All versions < V5.5.4), RUGGEDCOM RST916C (All versions < V5.5.4), RUGGEDCOM RST916P (All versions < V5.5.4). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution.
A vulnerability was determined in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function formSysRunCmd of the file /goform/SysRunCmd. This manipulation of the argument getui causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
Sagemcom F@ST 3686 v2 3.495 devices have a buffer overflow via a long sessionKey to the goform/login URI.
A vulnerability was detected in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function fromSafeClientFilter of the file /goform/SafeClientFilter. Performing manipulation of the argument page results in buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.
A vulnerability was identified in Tenda CH22 1.0.0.1. This affects the function fromRouteStatic of the file /goform/RouteStatic. Such manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.
A security vulnerability has been detected in TOTOLINK A3300R 17.0.0cu.557_B20221024. This affects the function setDmzCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ip leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used.
An issue was discovered on Samsung mobile devices with N(7.x) and O(8.X) (Exynos chipsets) software. There is a Buffer overflow in the esecomm Trustlet, leading to arbitrary code execution. The Samsung ID is SVE-2018-12852 (October 2018).
Python 3.x through 3.9.1 has a buffer overflow in PyCArg_repr in _ctypes/callproc.c, which may lead to remote code execution in certain Python applications that accept floating-point numbers as untrusted input, as demonstrated by a 1e300 argument to c_double.from_param. This occurs because sprintf is used unsafely.
An issue was discovered on Samsung mobile devices with M(6.0) (Exynos or MediaTek chipsets) software. There is a buffer overflow in a Trustlet that can cause memory corruption. The Samsung ID is SVE-2018-11599 (July 2018).
An issue was discovered on Samsung mobile devices with software through 2017-11-03 (S.LSI modem chipsets). The Exynos modem chipset has a baseband buffer overflow. The Samsung ID is SVE-2017-10745 (January 2018).
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.34, DM200 before 1.0.0.50, EX2700 before 1.0.1.32, EX6100v2 before 1.0.1.70, EX6150v2 before 1.0.1.70, EX6200v2 before 1.0.1.62, EX6400 before 1.0.1.78, EX7300 before 1.0.1.62, EX8000 before 1.0.0.114, R6100 before 1.0.1.22, R7500 before 1.0.0.122, R7500v2 before 1.0.3.26, R7800 before 1.0.2.40, R8900 before 1.0.3.10, R9000 before 1.0.3.10, WN2000RPTv3 before 1.0.1.26, WN3000RPv2 before 1.0.0.56, WN3000RPv3 before 1.0.2.66, WN3100RPv2 before 1.0.0.56, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.54, WNDR4500v3 before 1.0.0.54, and WNR2000v5 before 1.0.0.64.
An issue was discovered on Samsung mobile devices with N(7.x) and O(8.0) software. The sem Trustlet has a buffer overflow that leads to arbitrary TEE code execution. The Samsung IDs are SVE-2018-13230, SVE-2018-13231, SVE-2018-13232, SVE-2018-13233 (December 2018).
An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetSpeedWan speed_dir parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.
Buffer Overflow vulnerability in certain ABUS TVIP cameras allows attackers to gain control of the program via crafted string sent to sprintf() function.
TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a buffer overflow vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.
Buffer overflow in the regular expression handler in Red Hat Directory Server 8.0 and 7.1 before SP6 allows remote attackers to cause a denial of service (slapd crash) and possibly execute arbitrary code via a crafted LDAP query that triggers the overflow during translation to a regular expression.
A flaw was found in the gstreamer h264 component of gst-plugins-bad before v1.18.1 where when parsing a h264 header, an attacker could cause the stack to be smashed, memory corruption and possibly code execution.
Buffer overflow vulnerability in CLUSTERPRO X 5.0 for Windows and earlier, EXPRESSCLUSTER X 5.0 for Windows and earlier, CLUSTERPRO X 5.0 SingleServerSafe for Windows and earlier, EXPRESSCLUSTER X 5.0 SingleServerSafe for Windows and earlier allows a remote unauthenticated attacker to overwrite existing files on the file system and to potentially execute arbitrary code.
Milesight IP security cameras through 2016-11-14 have a buffer overflow in a web application via a long username or password.
A flaw has been found in UTT HiPER 810 1.7.4-141218. The impacted element is the function strcpy of the file /goform/setSysAdm. This manipulation of the argument passwd1 causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.
GVRET Stable Release as of Aug 15, 2015 was discovered to contain a buffer overflow via the handleConfigCmd function at SerialConsole.cpp.
LookupCol.c in X.Org X through X11R7.7 and libX11 before 1.7.1 might allow remote attackers to execute arbitrary code. The libX11 XLookupColor request (intended for server-side color lookup) contains a flaw allowing a client to send color-name requests with a name longer than the maximum size allowed by the protocol (and also longer than the maximum packet size for normal-sized packets). The user-controlled data exceeding the maximum size is then interpreted by the server as additional X protocol requests and executed, e.g., to disable X server authorization completely. For example, if the victim encounters malicious terminal control sequences for color codes, then the attacker may be able to take full control of the running graphical session.
A weakness has been identified in Tenda AC23 16.03.07.52. This affects the function sscanf of the file /goform/PowerSaveSet. Executing a manipulation of the argument Time can lead to buffer overflow. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks.