Improper authentication vulnerability exists in KB-AHR series and KB-IRIP series. If this vulnerability is exploited, an arbitrary OS command may be executed on the product or the device settings may be altered. Affected products and versions are as follows: KB-AHR04D versions prior to 91110.1.101106.78, KB-AHR08D versions prior to 91210.1.101106.78, KB-AHR16D versions prior to 91310.1.101106.78, KB-IRIP04A versions prior to 95110.1.100290.78A, KB-IRIP08A versions prior to 95210.1.100290.78A, and KB-IRIP16A versions prior to 95310.1.100290.78A.
mage-ai is an open-source data pipeline tool for transforming and integrating data. Those who use Mage starting in version 0.8.34 and prior to 0.8.72 with user authentication enabled may be affected by a vulnerability. The terminal could be accessed by users who are not signed in or do not have editor permissions. Version 0.8.72 contains a fix for this issue.
The router console is accessible without authentication at "data" field, and while a user needs to be logged in in order to modify the configuration, the session state is shared. If any other user is currently logged in, the anonymous user can execute commands in the context of the authenticated one. If the logged in user has administrative privileges, it is possible to use webadmin service configuration commands to create a new admin user with a chosen password.
An issue was discovered in Heimdal Thor agent versions 3.4.2 and before on Windows and 2.6.9 and before on macOS, allows attackers to bypass network filtering, execute arbitrary code, and obtain sensitive information via DarkLayer Guard threat prevention module. NOTE: Heimdal disputes the validity of this issue arguing that their DNS Security for Endpoint filters DNS traffic on the endpoint by intercepting system-generated DNS requests. The product was not designed to intercept DNS requests from third-party solutions.
NETGEAR ProSAFE Network Management System has Java Debug Wire Protocol (JDWP) listening on port 11611 and it is remotely accessible by unauthenticated users, allowing attackers to execute arbitrary code.
A vulnerability was found in harry0703 MoneyPrinterTurbo up to 1.2.6 and classified as critical. Affected by this issue is the function verify_token of the file app/controllers/base.py of the component API Endpoint. The manipulation leads to missing authentication. The attack may be launched remotely.
An unauthenticated remote attacker can manipulate the device via Telnet, stop processes, read, delete and change data.
Under certain circumstances, SAP HANA Extended Application Services, advanced model (XS advanced) does not perform authentication checks properly for XS advanced platform and business users. Fixed in 1.0.97 to 1.0.99 (running on SAP HANA 1 or SAP HANA 2 SPS0 (second S stands for stack)).
HiNet GPON firmware version < I040GWR190731 allows an attacker login to device without any authentication.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
A vulnerability was found in SimStudioAI sim up to 37786d371e17d35e0764e1b5cd519d873d90d97b. It has been declared as critical. Affected by this vulnerability is the function POST of the file apps/sim/app/api/files/upload/route.ts of the component Session Handler. The manipulation of the argument Request leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Array Networks Array AG Series and vxAG (9.4.0.481 and earlier) allow remote code execution. An attacker can browse the filesystem on the SSL VPN gateway using a flags attribute in an HTTP header without authentication. The product could then be exploited through a vulnerable URL. The 2023-03-09 vendor advisory stated "a new Array AG release with the fix will be available soon."
Vendor: The Apache Software Foundation Versions Affected: Apache OpenMeetings from 2.0.0 before 7.0.0 Description: Attacker can elevate their privileges in any room
The BookIt plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.3.7. This is due to insufficient verification on the user being supplied during booking an appointment through the plugin. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email.
A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future.
The User Email Verification for WooCommerce plugin for WordPress is vulnerable to authentication bypass via authenticate_user_by_email in versions up to, and including, 3.5.0. This is due to a random token generation weakness in the resend_verification_email function. This allows unauthenticated attackers to impersonate users and trigger an email address verification for arbitrary accounts, including administrative accounts, and automatically be logged in as that user, including any site administrators. This requires the Allow Automatic Login After Successful Verification setting to be enabled, which it is not by default.
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
A broken access control vulnerability in Smart Battery A4, a multifunctional portable charger, firmware version ?<= r1.7.9 allows an attacker to get/reset administrator’s password without any authentication.
A vulnerability has been found in TOTOLINK T6 4.1.5cu.748_B20211015 and classified as critical. Affected by this vulnerability is the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument telnet_enabled with the input 1 leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Moxa MiiNePort E1 has a vulnerability of insufficient access control. An unauthenticated remote user can exploit this vulnerability to perform arbitrary system operation or disrupt service.
Contec Smart Home 4.15 devices do not require authentication for new_user.php, edit_user.php, delete_user.php, and user.php, as demonstrated by changing the admin password and then obtaining control over doors.
An issue in Quectel BC95-CNV V100R001C00SPC051 allows attackers to bypass authentication via a crafted NAS message.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON products that implement FINS protocol contain following security issues -- (1)Plaintext communication, and (2)No authentication required. When FINS messages are intercepted, the contents may be retrieved. When arbitrary FINS messages are injected, any commands may be executed on, or the system information may be retrieved from, the affected device. Affected products and versions are as follows: SYSMAC CS-series CPU Units, all versions, SYSMAC CJ-series CPU Units, all versions, SYSMAC CP-series CPU Units, all versions, SYSMAC NJ-series CPU Units, all versions, SYSMAC NX1P-series CPU Units, all versions, SYSMAC NX102-series CPU Units, all versions, and SYSMAC NX7 Database Connection CPU Units (Ver.1.16 or later)
The BP Social Connect plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 1.5. This is due to insufficient verification on the user being supplied during a Facebook login through the plugin. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email.
Due to missing authentication and input sanitization of code the EventLogServiceCollector of SAP Diagnostics Agent - version 720, allows an attacker to execute malicious scripts on all connected Diagnostics Agents running on Windows. On successful exploitation, the attacker can completely compromise confidentiality, integrity and availability of the system.
The resolution SAML SSO apps for Atlassian products allow a remote attacker to login to a user account when only the username is known (i.e., no other authentication is provided). The fixed versions are for Jira: 3.6.6.1, 4.0.12, 5.0.5; for Confluence 3.6.6, 4.0.12, 5.0.5; for Bitbucket 2.5.9, 3.6.6, 4.0.12, 5.0.5; for Bamboo 2.5.9, 3.6.6, 4.0.12, 5.0.5; and for Fisheye 2.5.9.
The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface.
The default configuration in Apache Cassandra 3.8 through 3.11.1 binds an unauthenticated JMX/RMI interface to all network interfaces, which allows remote attackers to execute arbitrary Java code via an RMI request. This issue is a regression of CVE-2015-0225. The regression was introduced in https://issues.apache.org/jira/browse/CASSANDRA-12109. The fix for the regression is implemented in https://issues.apache.org/jira/browse/CASSANDRA-14173. This fix is contained in the 3.11.2 release of Apache Cassandra.
IBM Security Identity Governance and Intelligence 5.2.6 does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. IBM X-Force ID: 192209.
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
A vulnerability classified as critical has been found in code-projects Laundry System 1.0. This affects an unknown part of the file /data/. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Multiple camera devices by UDP Technology, Geutebrück and other vendors allow unauthenticated remote access to sensitive files due to default user authentication settings. This can lead to manipulation of the device and denial of service.
HGiga PowerStation has a vulnerability of Information Leakage. An unauthenticated remote attacker can exploit this vulnerability to obtain the administrator's credential. This credential can then be used to login PowerStation or Secure Shell to achieve remote code execution.
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). The supported version that is affected is 12.2.1.3.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
The MStore API plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.1.5. This is due to unrestricted access to the 'register' and 'update_user_profile' routes. This makes it possible for unauthenticated attackers to create new administrator accounts, delete existing administrator accounts, or escalate privileges on any account.
The Wordable plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 3.1.1. This is due to the use of a user supplied hashing algorithm passed to the hash_hmac() function and the use of a loose comparison on the hash which allows an attacker to trick the function into thinking it has a valid hash. This makes it possible for unauthenticated attackers to gain administrator privileges.
A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to a missing authentication process within the firmware upgrade function. An attacker could exploit this vulnerability by upgrading an affected device to a crafted version of firmware. A successful exploit could allow the attacker to execute arbitrary code on the affected device with full privileges. Cisco has not released firmware updates to address this vulnerability.
SnapCenter versions 4.7 prior to 4.7P2 and 4.8 prior to 4.8P1 are susceptible to a vulnerability which could allow a remote unauthenticated attacker to gain access as an admin user.
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.