The SolarWinds Orion API is vulnerable to an authentication bypass that could allow a remote attacker to execute API commands. This vulnerability could allow a remote attacker to bypass authentication and execute API commands which may result in a compromise of the SolarWinds instance. SolarWinds Orion Platform versions 2019.4 HF 5, 2020.2 with no hotfix installed, and 2020.2 HF 1 are affected.
The BookIt plugin for WordPress is vulnerable to authentication bypass in versions up to, and including, 2.3.7. This is due to insufficient verification on the user being supplied during booking an appointment through the plugin. This makes it possible for unauthenticated attackers to log in as any existing user on the site, such as an administrator, if they have access to the email.
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
Victure PC530 devices allow unauthenticated TELNET access as root.
Jector Smart TV FM-K75 devices allow remote code execution because there is an adb open port with root permission.
eQ-3 Homematic CCU2 before 2.47.18 and CCU3 before 3.47.18 allow Remote Code Execution by unauthenticated attackers with access to the web interface via an HTTP POST request to certain URLs related to the ReGa core process.
The administrative web server component of TIBCO Software Inc.'s TIBCO ActiveMatrix BPM, TIBCO ActiveMatrix BPM Distribution for TIBCO Silver Fabric, TIBCO ActiveMatrix Policy Director, TIBCO ActiveMatrix Service Bus, TIBCO ActiveMatrix Service Grid, TIBCO ActiveMatrix Service Grid Distribution for TIBCO Silver Fabric, TIBCO Silver Fabric Enabler for ActiveMatrix BPM, and TIBCO Silver Fabric Enabler for ActiveMatrix Service Grid contains a vulnerability that could theoretically allow an unauthenticated user to download a file with credentials information. Affected releases are TIBCO Software Inc.'s TIBCO ActiveMatrix BPM: versions up to and including 4.2.0, TIBCO ActiveMatrix BPM Distribution for TIBCO Silver Fabric: versions up to and including 4.2.0, TIBCO ActiveMatrix Policy Director: versions up to and including 1.1.0, TIBCO ActiveMatrix Service Bus: versions up to and including 3.3.0, TIBCO ActiveMatrix Service Grid: versions up to and including 3.3.1, TIBCO ActiveMatrix Service Grid Distribution for TIBCO Silver Fabric: versions up to and including 3.3.0, TIBCO Silver Fabric Enabler for ActiveMatrix BPM: versions up to and including 1.4.1, and TIBCO Silver Fabric Enabler for ActiveMatrix Service Grid: versions up to and including 1.3.1.
Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories.
A vulnerability in the web-based management interface of ClearPass Policy Manager could allow an unauthenticated remote attacker to create arbitrary users on the platform. A successful exploit allows an attacker to achieve total cluster compromise.
ONTAP Select Deploy administration utility versions 2.12 & 2.12.1 ship with an HTTP service bound to the network allowing unauthenticated remote attackers to perform administrative actions.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
HiNet GPON firmware version < I040GWR190731 allows an attacker login to device without any authentication.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
An issue in Quectel BC95-CNV V100R001C00SPC051 allows attackers to bypass authentication via a crafted NAS message.
It was found that default configuration of Heketi does not require any authentication potentially exposing the management interface to misuse. This isue only affects heketi as shipped with Openshift Container Platform 3.11.
A broken access control vulnerability in Smart Battery A4, a multifunctional portable charger, firmware version ?<= r1.7.9 allows an attacker to get/reset administrator’s password without any authentication.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 Version 3.37 and prior, G-50-W Version 3.37 and prior, G-50A Version 3.37 and prior, GB-50 Version 3.37 and prior, GB-50A Version 3.37 and prior, GB-24A Version 9.12 and prior, G-150AD Version 3.21 and prior, AG-150A-A Version 3.21 and prior, AG-150A-J Version 3.21 and prior, GB-50AD Version 3.21 and prior, GB-50ADA-A Version 3.21 and prior, GB-50ADA-J Version 3.21 and prior, EB-50GU-A Version 7.11 and prior, EB-50GU-J Version 7.11 and prior, AE-200J Version 8.01 and prior, AE-200A Version 8.01 and prior, AE-200E Version 8.01 and prior, AE-50J Version 8.01 and prior, AE-50A Version 8.01 and prior, AE-50E Version 8.01 and prior, EW-50J Version 8.01 and prior, EW-50A Version 8.01 and prior, EW-50E Version 8.01 and prior, TE-200A Version 8.01 and prior, TE-50A Version 8.01 and prior, TW-50A Version 8.01 and prior, and CMS-RMD-J Version 1.40 and prior allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
KubeView through 0.1.31 allows attackers to obtain control of a Kubernetes cluster because api/scrape/kube-system does not require authentication, and retrieves certificate files that can be used for authentication as kube-admin. NOTE: the vendor's position is that KubeView was a "fun side project and a learning exercise," and not "very secure."
Systematic IRIS WebForms 5.4 and its functionalities can be accessed and used without any form of authentication.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
IBM Spectrum Protect Server 8.1 through 8.1.26 could allow attacker to bypass authentication due to improper session authentication which can result in access to unauthorized resources.
An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. Unauthenticated remote command execution can occur via the management portal.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link DCS-960L v1.07.102. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HNAP service, which listens on TCP port 80 by default. When parsing the SOAPAction request header, the process does not properly validate the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the admin user. Was ZDI-CAN-8458.
The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.
An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates.
An issue was discovered in the LifterLMS plugin through 3.34.5 for WordPress. The upload_import function in the class.llms.admin.import.php script is prone to an unauthenticated options import vulnerability that could lead to privilege escalation (administrator account creation), website redirection, and stored XSS.
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
Intesync Solismed 3.3sp has Incorrect Access Control.
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal).
authentik is an open-source identity provider. Versions prior to 2022.11.2 and 2022.10.2 are vulnerable to unauthorized user creation and potential account takeover. With the default flows, unauthenticated users can create new accounts in authentik. If a flow exists that allows for email-verified password recovery, this can be used to overwrite the email address of admin accounts and take over their accounts. authentik 2022.11.2 and 2022.10.2 fix this issue. As a workaround, a policy can be created and bound to the `default-user-settings-flow flow` with the contents `return request.user.is_authenticated`.
Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.
Langflow versions prior to 1.3.0 are susceptible to code injection in the /api/v1/validate/code endpoint. A remote and unauthenticated attacker can send crafted HTTP requests to execute arbitrary code.
NetAlertX is a network, presence scanner and alert framework. Prior to version 25.4.14, it is possible to bypass the authentication mechanism of NetAlertX to update settings without authentication. An attacker can trigger sensitive functions within util.php by sending crafted requests to /index.php. This issue has been patched in version 25.4.14.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
Vulnerability in the Oracle Scripting product of Oracle E-Business Suite (component: iSurvey Module). Supported versions that are affected are 12.2.3-12.2.14. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Scripting. Successful attacks of this vulnerability can result in takeover of Oracle Scripting. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
An issue was discovered in ONAP SDC through Dublin. By accessing port 4000 of demo-sdc-sdc-be pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/guest-mode/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable passwordless guest mode via crafted HTTP requests.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
In ONAP MSB through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.