Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2020-7530

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-16 Sep, 2020 | 15:40
Updated At-04 Aug, 2024 | 09:33
Rejected At-
Credits

A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:16 Sep, 2020 | 15:40
Updated At:04 Aug, 2024 | 09:33
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders.

Affected Products
Vendor
n/a
Product
SCADAPack 7x Remote Connect V3.6.3.574 and prior.
Versions
Affected
  • SCADAPack 7x Remote Connect V3.6.3.574 and prior.
Problem Types
TypeCWE IDDescription
CWECWE-285CWE-285 Improper Authorization
Type: CWE
CWE ID: CWE-285
Description: CWE-285 Improper Authorization
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-252-01/
x_refsource_MISC
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-252-01/
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-252-01/
x_refsource_MISC
x_transferred
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-252-01/
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:16 Sep, 2020 | 16:15
Updated At:03 Sep, 2022 | 03:47

A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

Schneider Electric SE
schneider-electric
>>scadapack_7x_remote_connect>>Versions up to 3.6.3.574(inclusive)
cpe:2.3:a:schneider-electric:scadapack_7x_remote_connect:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
NVD-CWE-OtherPrimarynvd@nist.gov
CWE-285Secondarycybersecurity@se.com
CWE ID: NVD-CWE-Other
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-285
Type: Secondary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.se.com/ww/en/download/document/SEVD-2020-252-01/cybersecurity@se.com
Vendor Advisory
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-252-01/
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

204Records found

CVE-2022-32521
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.1||HIGH
EPSS-1.50% / 80.79%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2022-34753
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-91.20% / 99.64%
||
7 Day CHG-0.64%
Published-13 Jul, 2022 | 21:10
Updated-16 Sep, 2024 | 19:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)

Action-Not Available
Vendor-
Product-spacelogic_c-bus_home_controllerspacelogic_c-bus_home_controller_firmwareSpaceLogic C-Bus Home Controller
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-30232
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-1.07% / 77.33%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-17 Sep, 2024 | 04:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-powerlogic_ion_setup_firmwarepowerlogic_ion_setupPower Logic ION Setup
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7240
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.41% / 61.02%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious firmware.

Action-Not Available
Vendor-
Product-140cpu65160c140cpu65150140cpu65160c_firmware140cpu65160s140cpu65260_firmware140cpu65160_firmware140cpu65160s_firmware140cpu65860_firmware140cpu43412uc_firmware140cpu65860140cpu65260c140cpu65150c140cpu43412u_firmware140cpu31110140cpu65160140cpu65150c_firmware140cpu65260c_firmware140cpu65150_firmware140cpu65860c140cpu31110_firmware140cpu31110c140cpu65260140cpu31110c_firmware140cpu43412u140cpu43412uc140cpu65860c_firmwareModicon Quantum
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-37038
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.40% / 59.81%
||
7 Day CHG~0.00%
Published-12 Jun, 2024 | 16:51
Updated-02 Aug, 2024 | 03:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.

Action-Not Available
Vendor-
Product-sage_4400sage_1410sage_3030_magnumsage_2400sage_rtu_firmwaresage_1450sage_1430Sage 4400Sage 1450Sage 1410Sage 3030 MagnumSage 1430Sage 2400sage_4400sage_1410sage_2400sage_1450sage_3030msage_1430
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2021-22735
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.84% / 74.36%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remote code execution when unauthorized code is copied to the device.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-347
Improper Verification of Cryptographic Signature
CVE-2020-7572
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.47% / 63.83%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:02
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser.

Action-Not Available
Vendor-n/a
Product-webreportsEcoStruxure Building Operation WebReports V1.9 - V3.1
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2020-7547
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.94%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.

Action-Not Available
Vendor-n/a
Product-ecostruxure_energy_expertpower_managerpowerscada_expert_with_advanced_reporting_and_dashboardspowerscada_operation_with_advanced_reporting_and_dashboardsecostruxure_power_monitoring_expertEcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
CWE ID-CWE-284
Improper Access Control
CVE-2020-7545
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.46% / 63.68%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.

Action-Not Available
Vendor-n/a
Product-ecostruxure_energy_expertpower_managerpowerscada_expert_with_advanced_reporting_and_dashboardspowerscada_operation_with_advanced_reporting_and_dashboardsecostruxure_power_monitoring_expertEcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
CWE ID-CWE-284
Improper Access Control
CVE-2020-7509
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.40% / 60.07%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-269: Improper privilege management (write) vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to elevate their privileges and delete files.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (Firmware version 1.5.2 and older)
CWE ID-CWE-269
Improper Privilege Management
CVE-2022-30238
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.3||HIGH
EPSS-0.37% / 58.10%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-17 Sep, 2024 | 03:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-287
Improper Authentication
CVE-2020-28213
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.88%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:03
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertPLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)
CWE ID-CWE-494
Download of Code Without Integrity Check
CVE-2023-29410
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.15% / 36.35%
||
7 Day CHG+0.01%
Published-18 Apr, 2023 | 21:13
Updated-05 Feb, 2025 | 20:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.

Action-Not Available
Vendor-Schneider Electric SE
Product-insightfacility_firmwareinsighthomeconext_gateway_firmwareinsightfacilityconext_gatewayinsighthome_firmwareInsightFacilityInsightHomeConext Gateway
CWE ID-CWE-20
Improper Input Validation
CVE-2023-25547
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-5.79% / 90.29%
||
7 Day CHG+0.34%
Published-18 Apr, 2023 | 20:31
Updated-12 Feb, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-25548
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.66%
||
7 Day CHG+0.03%
Published-18 Apr, 2023 | 20:32
Updated-03 Mar, 2025 | 19:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-863
Incorrect Authorization
CVE-2019-6839
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.48% / 64.78%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:17
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file.

Action-Not Available
Vendor-n/a
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0001_firmwaremeg6501-0002meg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Servers (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, and MEG6260-0415 - U.motion KNX Server Plus, Touch 1)
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2019-6810
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.51% / 66.00%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:52
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.

Action-Not Available
Vendor-
Product-bmxnor0200h_firmwarebmxnor0200hBMXNOR0200H Ethernet / Serial RTU module
CWE ID-CWE-284
Improper Access Control
CVE-2021-22720
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-7.83% / 91.79%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 18:32
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit V1.15.7 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22748
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-3.80% / 87.81%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22717
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-11.59% / 93.48%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 18:31
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit V1.15.7 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22734
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.84% / 74.36%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Verification of Cryptographic Signature vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause remote code execution when an attacker loads unauthorized code.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-347
Improper Verification of Cryptographic Signature
CVE-2021-22793
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.54% / 67.22%
||
7 Day CHG~0.00%
Published-02 Sep, 2021 | 16:53
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.

Action-Not Available
Vendor-n/a
Product-accusine_pcsnaccusine_pcsn_active_harmonic_filter_firmwareaccusine_pcs\+accusine_pfv\+accusine_pcsp_pfvp_firmwareAccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2023-37196
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.42%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 06:22
Updated-07 Nov, 2024 | 14:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-22719
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-13.60% / 94.07%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 18:32
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit V1.15.7 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22708
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.24% / 47.49%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to craft a malicious firmware package and bypass the signature verification mechanism.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-347
Improper Verification of Cryptographic Signature
CVE-2023-37197
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.42%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 06:41
Updated-07 Nov, 2024 | 14:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7825
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.05% / 77.16%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:32
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen PelcoSarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-7806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.76% / 72.84%
||
7 Day CHG~0.00%
Published-30 Nov, 2018 | 19:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Data Center Operation allows for the upload of a zip file from its user interface to the server. A carefully crafted, malicious file could be mistakenly uploaded by an authenticated user via this feature which could contain path traversal file names. As such, it could allow for the arbitrary upload of files contained with the zip onto the server file system outside of the intended directory. This is leveraging the more commonly known ZipSlip vulnerability within Java code.

Action-Not Available
Vendor-
Product-struxureware_data_center_operationData Center Operation all versions
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2018-7832
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.21% / 78.63%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched.

Action-Not Available
Vendor-
Product-pro-face_gp-pro_exPro-Face GP-Pro EX v4.08 and previous versions
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7826
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.05% / 77.16%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:33
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-7802
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.71% / 71.88%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A SQL Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could give access to the web interface with full privileges.

Action-Not Available
Vendor-
Product-evlink_parkingevlink_parking_firmwareEVLink Parking v3.2.0-12_v1 and earlier
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7807
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.76% / 72.84%
||
7 Day CHG~0.00%
Published-30 Nov, 2018 | 19:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Data Center Expert, versions 7.5.0 and earlier, allows for the upload of a zip file from its user interface to the server. A carefully crafted, malicious file could be mistakenly uploaded by an authenticated user via this feature which could contain path traversal file names. As such, it could allow for the arbitrary upload of files contained with the zip onto the server file system outside of the intended directory. This is leveraging the more commonly known ZipSlip vulnerability within Java code.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertData Center Expert versions 7.5.0 and earlier
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2018-7777
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-15.81% / 94.57%
||
7 Day CHG+7.58%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 03:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-20
Improper Input Validation
CVE-2020-7569
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.45% / 80.46%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:02
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution.

Action-Not Available
Vendor-n/a
Product-webreportsEcoStruxure Building Operation WebReports V1.9 - V3.1
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2020-7564
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.23% / 78.88%
||
7 Day CHG~0.00%
Published-18 Nov, 2020 | 13:51
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP.

Action-Not Available
Vendor-n/a
Product-modicon_quantum_140cpu65150c_firmwaremodicon_m340_bmx_p34-2010_firmwaremodicon_m340_bmx_noe_0100h_firmwaremodicon_tsxp575634modicon_quantum_140noe77101_firmwaremodicon_m340_bmx_noc_0401modicon_quantum_140cpu65160c_firmwaremodicon_tsxp576634_firmwaremodicon_tsxety5103modicon_tsxp576634modicon_quantum_140cpu65160modicon_quantum_140noe77111_firmwaremodicon_tsxp575634_firmwaremodicon_m340_bmx_noe_0110hmodicon_quantum_140cpu65160_firmwaremodicon_m340_bmx_noe_0100_firmwaremodicon_m340_bmx_noe_0110_firmwaremodicon_m340_bmx_noe_0110h_firmwaremodicon_quantum_140cpu65160cmodicon_m340_bmx_nor_0200hmodicon_quantum_140cpu65150_firmwaremodicon_m340_bmx_p34-2030modicon_quantum_140cpu65150cmodicon_quantum_140cpu65150modicon_tsxety5103_firmwaremodicon_quantum_140noe77101modicon_m340_bmx_noc_0401_firmwaremodicon_m340_bmx_noe_0100hmodicon_tsxety4103modicon_m340_bmx_noe_0110modicon_quantum_140noc78100modicon_m340_bmx_noe_0100modicon_tsxp574634_firmwaremodicon_quantum_140noc78100_firmwaremodicon_m340_bmx_nor_0200h_firmwaremodicon_quantum_140noe77111modicon_m340_bmx_p34-2010modicon_m340_bmx_p34-2030_firmwaremodicon_tsxety4103_firmwaremodicon_tsxp574634Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-7563
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.04% / 77.09%
||
7 Day CHG~0.00%
Published-18 Nov, 2020 | 13:50
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP.

Action-Not Available
Vendor-n/a
Product-modicon_quantum_140cpu65150c_firmwaremodicon_m340_bmx_p34-2010_firmwaremodicon_m340_bmx_noe_0100h_firmwaremodicon_tsxp575634modicon_quantum_140noe77101_firmwaremodicon_m340_bmx_noc_0401modicon_quantum_140cpu65160c_firmwaremodicon_tsxp576634_firmwaremodicon_tsxety5103modicon_tsxp576634modicon_quantum_140cpu65160modicon_quantum_140noe77111_firmwaremodicon_tsxp575634_firmwaremodicon_m340_bmx_noe_0110hmodicon_quantum_140cpu65160_firmwaremodicon_m340_bmx_noe_0100_firmwaremodicon_m340_bmx_noe_0110_firmwaremodicon_m340_bmx_noe_0110h_firmwaremodicon_quantum_140cpu65160cmodicon_m340_bmx_nor_0200hmodicon_quantum_140cpu65150_firmwaremodicon_m340_bmx_p34-2030modicon_quantum_140cpu65150cmodicon_quantum_140cpu65150modicon_tsxety5103_firmwaremodicon_quantum_140noe77101modicon_m340_bmx_noc_0401_firmwaremodicon_m340_bmx_noe_0100hmodicon_tsxety4103modicon_m340_bmx_noe_0110modicon_quantum_140noc78100modicon_m340_bmx_noe_0100modicon_tsxp574634_firmwaremodicon_quantum_140noc78100_firmwaremodicon_m340_bmx_nor_0200h_firmwaremodicon_quantum_140noe77111modicon_m340_bmx_p34-2010modicon_m340_bmx_p34-2030_firmwaremodicon_tsxety4103_firmwaremodicon_tsxp574634Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details)
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7501
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.94%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:40
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer.

Action-Not Available
Vendor-n/a
Product-vijeo_designerVijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2022-4062
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.05% / 16.92%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-285: Improper Authorization vulnerability exists that could cause unauthorized access to certain software functions when an attacker gets access to localhost interface of the EcoStruxure Power Commission application. Affected Products: EcoStruxure Power Commission (Versions prior to V2.25)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-285
Improper Authorization
CVE-2025-13118
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 14.59%
||
7 Day CHG~0.00%
Published-13 Nov, 2025 | 15:02
Updated-25 Nov, 2025 | 16:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
macrozheng mall-swarm/mall paySuccess improper authorization

A vulnerability was detected in macrozheng mall-swarm and mall up to 1.0.3. Affected by this issue is the function paySuccess of the file /order/paySuccess. The manipulation of the argument orderID results in improper authorization. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-macrozhengmacrozheng
Product-mall-swarmmallmallmall-swarm
CWE ID-CWE-266
Incorrect Privilege Assignment
CWE ID-CWE-285
Improper Authorization
CVE-2021-32688
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-3.11% / 86.51%
||
7 Day CHG~0.00%
Published-12 Jul, 2021 | 13:45
Updated-03 Aug, 2024 | 23:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Application specific tokens can change their own scope

Nextcloud Server is a Nextcloud package that handles data storage. Nextcloud Server supports application specific tokens for authentication purposes. These tokens are supposed to be granted to a specific applications (e.g. DAV sync clients), and can also be configured by the user to not have any filesystem access. Due to a lacking permission check, the tokens were able to change their own permissions in versions prior to 19.0.13, 20.0.11, and 21.0.3. Thus fileystem limited tokens were able to grant themselves access to the filesystem. The issue is patched in versions 19.0.13, 20.0.11, and 21.0.3. There are no known workarounds aside from upgrading.

Action-Not Available
Vendor-Fedora ProjectNextcloud GmbH
Product-fedoranextcloud_serversecurity-advisories
CWE ID-CWE-285
Improper Authorization
CWE ID-CWE-552
Files or Directories Accessible to External Parties
CVE-2025-13114
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.04% / 10.59%
||
7 Day CHG~0.00%
Published-13 Nov, 2025 | 13:32
Updated-25 Nov, 2025 | 17:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
macrozheng mall-swarm attr updateAttr improper authorization

A vulnerability was identified in macrozheng mall-swarm up to 1.0.3. This affects the function updateAttr of the file /cart/update/attr. Such manipulation leads to improper authorization. The attack may be performed from remote. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-macrozhengmacrozheng
Product-mall-swarmmall-swarm
CWE ID-CWE-266
Incorrect Privilege Assignment
CWE ID-CWE-285
Improper Authorization
CVE-2021-32620
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.83%
||
7 Day CHG~0.00%
Published-28 May, 2021 | 21:05
Updated-03 Aug, 2024 | 23:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Users registered with email verification can self re-activate their disabled accounts

XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. In versions prior to 11.10.13, 12.6.7, and 12.10.2, a user disabled on a wiki using email verification for registration canouldre-activate themself by using the activation link provided for his registration. The problem has been patched in the following versions of XWiki: 11.10.13, 12.6.7, 12.10.2, 13.0. It is possible to workaround the issue by resetting the `validkey` property of the disabled XWiki users. This can be done by editing the user profile with object editor.

Action-Not Available
Vendor-XWiki SAS
Product-xwikixwiki-platform
CWE ID-CWE-285
Improper Authorization
CWE ID-CWE-863
Incorrect Authorization
CVE-2025-12288
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.04% / 10.27%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 14:32
Updated-24 Nov, 2025 | 12:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Bdtask Pharmacy Management System User Profile edit_user authorization

A vulnerability was detected in Bdtask Pharmacy Management System up to 9.4. Affected is an unknown function of the file /user/edit_user/ of the component User Profile Handler. Performing manipulation results in authorization bypass. Remote exploitation of the attack is possible. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-bdtaskBdtask
Product-pharmacarePharmacy Management System
CWE ID-CWE-285
Improper Authorization
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2017-16773
Matching Score-4
Assigner-Synology Inc.
ShareView Details
Matching Score-4
Assigner-Synology Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.14% / 33.44%
||
7 Day CHG~0.00%
Published-05 Jul, 2018 | 13:00
Updated-17 Sep, 2024 | 00:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper authorization vulnerability in Highlight Preview in Synology Universal Search before 1.0.5-0135 allows remote authenticated users to bypass permission checks for directories in POSIX mode.

Action-Not Available
Vendor-Synology, Inc.
Product-universal_searchUniversal Search
CWE ID-CWE-285
Improper Authorization
CWE ID-CWE-863
Incorrect Authorization
CVE-2018-19569
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.26% / 48.99%
||
7 Day CHG~0.00%
Published-10 Jul, 2019 | 15:56
Updated-05 Aug, 2024 | 11:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

GitLab CE/EE, versions 8.8 up to 11.x before 11.3.11, 11.4 before 11.4.8, and 11.5 before 11.5.1, are vulnerable to an authorization vulnerability that allows access to the web-UI as a user using a Personal Access Token of any scope.

Action-Not Available
Vendor-n/aGitLab Inc.
Product-gitlabn/a
CWE ID-CWE-285
Improper Authorization
CVE-2021-32523
Matching Score-4
Assigner-TWCERT/CC
ShareView Details
Matching Score-4
Assigner-TWCERT/CC
CVSS Score-9.1||CRITICAL
EPSS-0.23% / 45.59%
||
7 Day CHG~0.00%
Published-07 Jul, 2021 | 14:12
Updated-16 Sep, 2024 | 23:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
QSAN Storage Manager - Improper Authorization

Improper authorization vulnerability in QSAN Storage Manager allows remote privileged users to bypass the access control and execute arbitrary commands. Suggest contacting with QSAN and refer to recommendations in QSAN Document.

Action-Not Available
Vendor-qsanQSAN
Product-storage_managerStorage Manager
CWE ID-CWE-285
Improper Authorization
CVE-2025-11050
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 19.34%
||
7 Day CHG~0.00%
Published-27 Sep, 2025 | 04:32
Updated-03 Oct, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Portabilis i-Educar periodo-lancamento improper authorization

A flaw has been found in Portabilis i-Educar up to 2.10. This affects an unknown part of the file /periodo-lancamento. Executing manipulation can lead to improper authorization. The attack can be executed remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-portabilisPortabilis
Product-i-educari-Educar
CWE ID-CWE-266
Incorrect Privilege Assignment
CWE ID-CWE-285
Improper Authorization
CVE-2025-10277
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 8.03%
||
7 Day CHG-0.03%
Published-12 Sep, 2025 | 03:02
Updated-14 Nov, 2025 | 20:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
YunaiV yudao-cloud submit improper authorization

A vulnerability was detected in YunaiV yudao-cloud up to 2025.09. This issue affects some unknown processing of the file /crm/receivable/submit. The manipulation of the argument ID results in improper authorization. The attack can be executed remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-iocoderYunaiV
Product-yudao-cloudyudao-cloud
CWE ID-CWE-266
Incorrect Privilege Assignment
CWE ID-CWE-285
Improper Authorization
CVE-2018-17933
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.29% / 51.87%
||
7 Day CHG~0.00%
Published-30 Oct, 2018 | 21:00
Updated-05 Aug, 2024 | 11:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) connected to the VGo XAMPP. User accounts may be able to execute commands that are outside the scope of their privileges and within the scope of an admin account. If an attacker has access to VGo XAMPP Client credentials, they may be able to execute admin commands on the connected robot.

Action-Not Available
Vendor-vecnan/a
Product-vgo_firmwarevgoVGo Robot
CWE ID-CWE-285
Improper Authorization
CVE-2025-10318
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 9.15%
||
7 Day CHG-0.04%
Published-12 Sep, 2025 | 12:32
Updated-31 Dec, 2025 | 01:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
JeecgBoot WebSocket Message sendWebSocketMsg improper authorization

A vulnerability was identified in JeecgBoot up to 3.8.2. Affected by this vulnerability is an unknown functionality of the file /api/system/sendWebSocketMsg of the component WebSocket Message Handler. The manipulation of the argument userIds leads to improper authorization. The attack can be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-jeecgn/a
Product-jeecg_bootJeecgBoot
CWE ID-CWE-266
Incorrect Privilege Assignment
CWE ID-CWE-285
Improper Authorization
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • Next
Details not found