A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file.
CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report.
A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer.
A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders.
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP.
A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP.
A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.
A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution.
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete control of the device when an authenticated user installs malicious code into HMI product.
CWE-639: Authorization Bypass Through User-Controlled Key vulnerability exists that could allow an authorized attacker to modify values outside those defined by their privileges (Elevation of Privileges) when the attacker sends modified HTTPS requests to the device.
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE.
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to delete a critical file.
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file.
An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization.
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes.
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.
Improper Authorization in GitHub repository phpipam/phpipam prior to 1.4.6.
Exposure of Private Personal Information to an Unauthorized Actor in GitHub repository lquixada/cross-fetch prior to 3.1.5.
Jinjava before 2.5.4 allow access to arbitrary classes by calling Java methods on objects passed into a Jinjava context. This could allow for abuse of the application class loader, including Arbitrary File Disclosure.
An issue was discovered in OpenStack Keystone before 15.0.1, and 16.0.0. Any authenticated user can create an EC2 credential for themselves for a project that they have a specified role on, and then perform an update to the credential user and project, allowing them to masquerade as another user. This potentially allows a malicious user to act as the admin on a project another user has the admin role on, which can effectively grant that user global admin privileges.
Vulnerability in the Oracle Database component of Oracle Database Server. Supported versions that are affected are 19.27 and 23.4-23.8. Easily exploitable vulnerability allows low privileged attacker having Create Session, Create Procedure privilege with network access via Oracle Net to compromise Oracle Database. Successful attacks of this vulnerability can result in takeover of Oracle Database. CVSS 3.1 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).
A vulnerability was found in Ignition where ignition configs are accessible from unprivileged containers in VMs running on VMware products. This issue is only relevant in user environments where the Ignition config contains secrets. The highest threat from this vulnerability is to data confidentiality. Possible workaround is to not put secrets in the Ignition config.
Incorrect Authorization vulnerability in Apache Superset allows ownership takeover of dashboards, charts or datasets by authenticated users with read permissions. This issue affects Apache Superset: through 4.1.1. Users are recommended to upgrade to version 4.1.2 or above, which fixes the issue.
A regular Zabbix user can search other users in their user group via Zabbix API by select fields the user does not have access to view. This allows data-mining some field values the user does not have access to.
An authorization issue relating to project maintainer impersonation was identified in GitLab EE 9.5 and later through 13.0.1 that could allow unauthorized users to impersonate as a maintainer to perform limited actions.
Systems running the Instaclustr fork of Stratio's Cassandra-Lucene-Index plugin versions 4.0-rc1-1.0.0 through 4.0.16-1.0.0 and 4.1.2-1.0.0 through 4.1.8-1.0.0, installed into Apache Cassandra version 4.x, are susceptible to a vulnerability which when successfully exploited could allow authenticated Cassandra users to remotely bypass RBAC and escalate their privileges.
Incorrect Authorization in GitHub repository phpipam/phpipam prior to 1.4.6.
An authorization issue in the mirroring logic allowed read access to private repositories in GitLab CE/EE 10.6 and later through 13.0.5
A flaw was found in Quarkus. The state and potentially associated permissions can leak from one web request to another in RestEasy Reactive. This flaw allows a low-privileged user to perform operations on the database with a different set of privileges than intended.
The UpdraftPlus WordPress plugin Free before 1.22.3 and Premium before 2.22.3 do not properly validate a user has the required privileges to access a backup's nonce identifier, which may allow any users with an account on the site (such as subscriber) to download the most recent site & database backup.
Dart SDK contains the HTTPClient in dart:io library whcih includes authorization headers when handling cross origin redirects. These headers may be explicitly set and contain sensitive information. By default, HttpClient handles redirection logic. If a request is sent to example.com with authorization header and it redirects to an attackers site, they might not expect attacker site to receive authorization header. We recommend updating the Dart SDK to version 2.16.0 or beyond.