Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-25547

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-18 Apr, 2023 | 20:31
Updated At-12 Feb, 2025 | 16:00
Rejected At-
Credits

A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:18 Apr, 2023 | 20:31
Updated At:12 Feb, 2025 | 16:00
Rejected At:
â–¼CVE Numbering Authority (CNA)

A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Affected Products
Vendor
Schneider Electric SESchneider Electric
Product
StruxureWare Data Center Expert
Default Status
unaffected
Versions
Affected
  • From All through V7.9.2 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-863CWE-863 Incorrect Authorization
Type: CWE
CWE ID: CWE-863
Description: CWE-863 Incorrect Authorization
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf
N/A
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf
Resource: N/A
â–¼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:18 Apr, 2023 | 21:15
Updated At:27 Apr, 2023 | 19:36

A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Schneider Electric SE
schneider-electric
>>struxureware_data_center_expert>>Versions up to 7.9.2(inclusive)
cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-863Primarycybersecurity@se.com
CWE ID: CWE-863
Type: Primary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdfcybersecurity@se.com
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

264Records found

CVE-2023-25548
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.45%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:32
Updated-03 Mar, 2025 | 19:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-22719
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-8.53% / 92.48%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 18:32
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit V1.15.7 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22717
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-11.34% / 93.64%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 18:31
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit V1.15.7 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22748
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-3.80% / 88.23%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7569
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.45% / 81.02%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:02
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution.

Action-Not Available
Vendor-n/a
Product-webreportsEcoStruxure Building Operation WebReports V1.9 - V3.1
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2020-7563
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.04% / 77.71%
||
7 Day CHG~0.00%
Published-18 Nov, 2020 | 13:50
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP.

Action-Not Available
Vendor-n/a
Product-modicon_quantum_140cpu65150c_firmwaremodicon_m340_bmx_p34-2010_firmwaremodicon_m340_bmx_noe_0100h_firmwaremodicon_tsxp575634modicon_quantum_140noe77101_firmwaremodicon_m340_bmx_noc_0401modicon_quantum_140cpu65160c_firmwaremodicon_tsxp576634_firmwaremodicon_tsxety5103modicon_tsxp576634modicon_quantum_140cpu65160modicon_quantum_140noe77111_firmwaremodicon_tsxp575634_firmwaremodicon_m340_bmx_noe_0110hmodicon_quantum_140cpu65160_firmwaremodicon_m340_bmx_noe_0100_firmwaremodicon_m340_bmx_noe_0110_firmwaremodicon_m340_bmx_noe_0110h_firmwaremodicon_quantum_140cpu65160cmodicon_m340_bmx_nor_0200hmodicon_quantum_140cpu65150_firmwaremodicon_m340_bmx_p34-2030modicon_quantum_140cpu65150cmodicon_quantum_140cpu65150modicon_tsxety5103_firmwaremodicon_quantum_140noe77101modicon_m340_bmx_noc_0401_firmwaremodicon_m340_bmx_noe_0100hmodicon_tsxety4103modicon_m340_bmx_noe_0110modicon_quantum_140noc78100modicon_m340_bmx_noe_0100modicon_tsxp574634_firmwaremodicon_quantum_140noc78100_firmwaremodicon_m340_bmx_nor_0200h_firmwaremodicon_quantum_140noe77111modicon_m340_bmx_p34-2010modicon_m340_bmx_p34-2030_firmwaremodicon_tsxety4103_firmwaremodicon_tsxp574634Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details)
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7572
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.47% / 64.61%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:02
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser.

Action-Not Available
Vendor-n/a
Product-webreportsEcoStruxure Building Operation WebReports V1.9 - V3.1
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2020-7564
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.23% / 79.44%
||
7 Day CHG~0.00%
Published-18 Nov, 2020 | 13:51
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP.

Action-Not Available
Vendor-n/a
Product-modicon_quantum_140cpu65150c_firmwaremodicon_m340_bmx_p34-2010_firmwaremodicon_m340_bmx_noe_0100h_firmwaremodicon_tsxp575634modicon_quantum_140noe77101_firmwaremodicon_m340_bmx_noc_0401modicon_quantum_140cpu65160c_firmwaremodicon_tsxp576634_firmwaremodicon_tsxety5103modicon_tsxp576634modicon_quantum_140cpu65160modicon_quantum_140noe77111_firmwaremodicon_tsxp575634_firmwaremodicon_m340_bmx_noe_0110hmodicon_quantum_140cpu65160_firmwaremodicon_m340_bmx_noe_0100_firmwaremodicon_m340_bmx_noe_0110_firmwaremodicon_m340_bmx_noe_0110h_firmwaremodicon_quantum_140cpu65160cmodicon_m340_bmx_nor_0200hmodicon_quantum_140cpu65150_firmwaremodicon_m340_bmx_p34-2030modicon_quantum_140cpu65150cmodicon_quantum_140cpu65150modicon_tsxety5103_firmwaremodicon_quantum_140noe77101modicon_m340_bmx_noc_0401_firmwaremodicon_m340_bmx_noe_0100hmodicon_tsxety4103modicon_m340_bmx_noe_0110modicon_quantum_140noc78100modicon_m340_bmx_noe_0100modicon_tsxp574634_firmwaremodicon_quantum_140noc78100_firmwaremodicon_m340_bmx_nor_0200h_firmwaremodicon_quantum_140noe77111modicon_m340_bmx_p34-2010modicon_m340_bmx_p34-2030_firmwaremodicon_tsxety4103_firmwaremodicon_tsxp574634Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-28213
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.51%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:03
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertPLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)
CWE ID-CWE-494
Download of Code Without Integrity Check
CVE-2023-37196
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.89%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 06:22
Updated-07 Nov, 2024 | 14:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-37197
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.89%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 06:41
Updated-07 Nov, 2024 | 14:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2020-7547
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.55%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.

Action-Not Available
Vendor-n/a
Product-ecostruxure_energy_expertpower_managerpowerscada_expert_with_advanced_reporting_and_dashboardspowerscada_operation_with_advanced_reporting_and_dashboardsecostruxure_power_monitoring_expertEcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
CWE ID-CWE-284
Improper Access Control
CVE-2023-29410
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.46% / 64.54%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 21:13
Updated-05 Feb, 2025 | 20:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.

Action-Not Available
Vendor-Schneider Electric SE
Product-insightfacility_firmwareinsighthomeconext_gateway_firmwareinsightfacilityconext_gatewayinsighthome_firmwareInsightFacilityInsightHomeConext Gateway
CWE ID-CWE-20
Improper Input Validation
CVE-2019-6810
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.50% / 66.05%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:52
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.

Action-Not Available
Vendor-
Product-bmxnor0200h_firmwarebmxnor0200hBMXNOR0200H Ethernet / Serial RTU module
CWE ID-CWE-284
Improper Access Control
CVE-2019-6839
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.48% / 65.55%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:17
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file.

Action-Not Available
Vendor-n/a
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0001_firmwaremeg6501-0002meg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Servers (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, and MEG6260-0415 - U.motion KNX Server Plus, Touch 1)
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2024-37038
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.40% / 60.53%
||
7 Day CHG~0.00%
Published-12 Jun, 2024 | 16:51
Updated-02 Aug, 2024 | 03:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.

Action-Not Available
Vendor-
Product-sage_4400sage_1410sage_3030_magnumsage_2400sage_rtu_firmwaresage_1450sage_1430Sage 4400Sage 1450Sage 1410Sage 3030 MagnumSage 1430Sage 2400sage_4400sage_1410sage_2400sage_1450sage_3030msage_1430
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2022-34753
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-93.80% / 99.86%
||
7 Day CHG~0.00%
Published-13 Jul, 2022 | 21:10
Updated-16 Sep, 2024 | 19:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)

Action-Not Available
Vendor-
Product-spacelogic_c-bus_home_controllerspacelogic_c-bus_home_controller_firmwareSpaceLogic C-Bus Home Controller
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-32521
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.1||HIGH
EPSS-1.50% / 81.34%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2022-30238
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.3||HIGH
EPSS-0.36% / 57.91%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-17 Sep, 2024 | 03:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-287
Improper Authentication
CVE-2020-7530
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.34% / 57.20%
||
7 Day CHG~0.00%
Published-16 Sep, 2020 | 15:40
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders.

Action-Not Available
Vendor-n/a
Product-scadapack_7x_remote_connectSCADAPack 7x Remote Connect V3.6.3.574 and prior.
CWE ID-CWE-285
Improper Authorization
CVE-2020-7501
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.55%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:40
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer.

Action-Not Available
Vendor-n/a
Product-vijeo_designerVijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2024-11999
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.35% / 57.61%
||
7 Day CHG~0.00%
Published-17 Dec, 2024 | 06:13
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete control of the device when an authenticated user installs malicious code into HMI product.

Action-Not Available
Vendor-
Product-Harmony (Formerly Magelis) HMIST6, HMISTM6, HMIG3U, HMIG3X, HMISTO7 series with EcoStruxure Operator Terminal Expert runtimePFXST6000, PFXSTM6000, PFXSP5000, PFXGP4100 series with Pro-face BLUE runtime
CWE ID-CWE-1104
Use of Unmaintained Third Party Components
CVE-2024-10497
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.04% / 12.41%
||
7 Day CHG~0.00%
Published-17 Jan, 2025 | 10:27
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-639: Authorization Bypass Through User-Controlled Key vulnerability exists that could allow an authorized attacker to modify values outside those defined by their privileges (Elevation of Privileges) when the attacker sends modified HTTPS requests to the device.

Action-Not Available
Vendor-Schneider Electric SE
Product-PowerLogic HDPM6000
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2022-30232
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-1.07% / 77.95%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-17 Sep, 2024 | 04:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-powerlogic_ion_setup_firmwarepowerlogic_ion_setupPower Logic ION Setup
CWE ID-CWE-20
Improper Input Validation
CVE-2020-7499
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.18% / 39.43%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:16
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes.

Action-Not Available
Vendor-n/a
Product-mtn6501-0001_firmwaremtn6260-0310_firmwaremtn6260-0315mtn6260-0415_firmwaremtn6260-0310mtn6501-0002mtn6260-0415mtn6501-0002_firmwaremtn6501-0001mtn6260-0315_firmwaremtn6260-0410mtn6260-0410_firmwareU.motion Servers and Touch Panels (affected versions listed in the security notification)
CWE ID-CWE-863
Incorrect Authorization
CVE-2019-6836
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.28% / 51.43%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:14
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file.

Action-Not Available
Vendor-n/a
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0001_firmwaremeg6501-0002meg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Servers (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, and MEG6260-0415 - U.motion KNX Server Plus, Touch 1)
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-22610
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-0.49% / 65.68%
||
7 Day CHG~0.00%
Published-31 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_geo_scada_expert_2021ecostruxure_geo_scada_expert_2020ecostruxure_geo_scada_expert_2019EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)
CWE ID-CWE-863
Incorrect Authorization
CVE-2019-6838
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.15% / 34.58%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:16
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to delete a critical file.

Action-Not Available
Vendor-n/a
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0002meg6501-0001_firmwaremeg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Servers (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, and MEG6260-0415 - U.motion KNX Server Plus, Touch 1)
CWE ID-CWE-863
Incorrect Authorization
CVE-2020-28211
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.06% / 17.23%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:03
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertPLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)
CWE ID-CWE-863
Incorrect Authorization
CVE-2018-7245
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-0.43% / 63.08%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization.

Action-Not Available
Vendor-
Product-mge_galaxy_4000mge_galaxy_5000mge_eps_8000mge_galaxy_pwmge_galaxy_300066074_mge_network_management_card_transversemge_comet_upsmge_eps_6000mge_galaxy_6000mge_galaxy_9000mge_eps_700066074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
CWE ID-CWE-863
Incorrect Authorization
CVE-2019-6855
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.3||HIGH
EPSS-0.19% / 40.65%
||
7 Day CHG~0.00%
Published-06 Jan, 2020 | 22:56
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.

Action-Not Available
Vendor-n/a
Product-modicon_m580_bmep582040_firmwaremodicon_m580_bmeh582040modicon_m580_bmep583040_firmwaremodicon_m340_bmxp3420302_firmwaremodicon_m580_bmep583020modicon_m580_bmeh586040s_firmwaremodicon_m580_bmeh584040smodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_m580_bmep584040s_firmwaremodicon_m580_bmep584040modicon_m580_bmeh586040modicon_m580_bmep582020modicon_m580_bmep583020_firmwaremodicon_m340_bmxp342000modicon_m340_bmxp341000modicon_m340_bmxp342020_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep584040smodicon_m580_bmep583040ecostruxure_control_expertmodicon_m580_bmep582040modicon_m580_bmep584020_firmwaremodicon_m580_bmeh584040modicon_m580_bmep585040modicon_m580_bmeh584040_firmwareunity_promodicon_m340_bmxp3420302modicon_m580_bmep584020modicon_m580_bmeh584040s_firmwaremodicon_m580_bmep582040s_firmwaremodicon_m580_bmep582040smodicon_m580_bmeh582040_firmwaremodicon_m340_bmxp342020modicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwaremodicon_m580_bmep581020modicon_m580_bmep582020_firmwaremodicon_m580_bmeh586040_firmwaremodicon_m340_bmxp342000_firmwaremodicon_m340_bmxp3420102modicon_m580_bmep586040_firmware EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10)
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-27661
Matching Score-4
Assigner-Johnson Controls
ShareView Details
Matching Score-4
Assigner-Johnson Controls
CVSS Score-8.8||HIGH
EPSS-0.19% / 40.63%
||
7 Day CHG~0.00%
Published-01 Jul, 2021 | 13:41
Updated-16 Sep, 2024 | 22:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Facility Explorer

Successful exploitation of this vulnerability could give an authenticated Facility Explorer SNC Series Supervisory Controller (F4-SNC) user an unintended level of access to the controller’s file system, allowing them to access or modify system files by sending specifically crafted web messages to the F4-SNC.

Action-Not Available
Vendor-johnsoncontrolsJohnson Controls
Product-f4-snc_firmwaref4-sncFacility Explorer SNC Series Supervisory Controllers (F4-SNC)
CWE ID-CWE-269
Improper Privilege Management
CWE ID-CWE-863
Incorrect Authorization
CVE-2020-13263
Matching Score-4
Assigner-GitLab Inc.
ShareView Details
Matching Score-4
Assigner-GitLab Inc.
CVSS Score-7.5||HIGH
EPSS-0.20% / 41.71%
||
7 Day CHG~0.00%
Published-19 Jun, 2020 | 22:15
Updated-04 Aug, 2024 | 12:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authorization issue relating to project maintainer impersonation was identified in GitLab EE 9.5 and later through 13.0.1 that could allow unauthorized users to impersonate as a maintainer to perform limited actions.

Action-Not Available
Vendor-GitLab Inc.
Product-gitlabGitLab
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-24717
Matching Score-4
Assigner-WPScan
ShareView Details
Matching Score-4
Assigner-WPScan
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.38%
||
7 Day CHG~0.00%
Published-01 Nov, 2021 | 08:46
Updated-03 Aug, 2024 | 19:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
AutomatorWP < 1.7.6 - Missing Authorization and Privilege Escalation

The AutomatorWP WordPress plugin before 1.7.6 does not perform capability checks which allows users with Subscriber roles to enumerate automations, disclose title of private posts or user emails, call functions, or perform privilege escalation via Ajax actions.

Action-Not Available
Vendor-automatorwpUnknown
Product-automatorwpAutomatorWP
CWE ID-CWE-863
Incorrect Authorization
CVE-2025-1214
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.13% / 32.15%
||
7 Day CHG~0.00%
Published-12 Feb, 2025 | 18:00
Updated-17 Oct, 2025 | 15:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
pihome-shc PiHome Role-Based Access Control user_accounts.php authorization

A vulnerability classified as critical has been found in pihome-shc PiHome 2.0. This affects an unknown part of the file /user_accounts.php?uid of the component Role-Based Access Control. The manipulation leads to missing authorization. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-pihomepihome-shc
Product-maxairPiHome
CWE ID-CWE-862
Missing Authorization
CWE ID-CWE-863
Incorrect Authorization
CVE-2016-4572
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.80%
||
7 Day CHG~0.00%
Published-26 Nov, 2019 | 13:51
Updated-06 Aug, 2024 | 00:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Cloudera CDH before 5.7.1, Impala REVOKE ALL ON SERVER commands do not revoke all privileges.

Action-Not Available
Vendor-clouderan/a
Product-cdhn/a
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-22966
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.20%
||
7 Day CHG~0.00%
Published-19 Nov, 2021 | 18:09
Updated-03 Aug, 2024 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Privilege escalation from Editor to Admin using Groups in Concrete CMS versions 8.5.6 and below. If a group is granted "view" permissions on the bulkupdate page, then users in that group can escalate to being an administrator with a specially crafted curl. Fixed by adding a check for group permissions before allowing a group to be moved. Concrete CMS Security team CVSS scoring: 7.1 AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:HCredit for discovery: "Adrian Tiron from FORTBRIDGE ( https://www.fortbridge.co.uk/ )"This fix is also in Concrete version 9.0.0

Action-Not Available
Vendor-concretecmsn/a
Product-concrete_cmshttps://github.com/concrete5/concrete5
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-22236
Matching Score-4
Assigner-GitLab Inc.
ShareView Details
Matching Score-4
Assigner-GitLab Inc.
CVSS Score-5.5||MEDIUM
EPSS-0.22% / 45.14%
||
7 Day CHG~0.00%
Published-25 Aug, 2021 | 18:39
Updated-03 Aug, 2024 | 18:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Due to improper handling of OAuth client IDs, new subscriptions generated OAuth tokens on an incorrect OAuth client application. This vulnerability is present in GitLab CE/EE since version 14.1.

Action-Not Available
Vendor-GitLab Inc.
Product-gitlabGitLab
CWE ID-CWE-863
Incorrect Authorization
CVE-2026-30944
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-0.06% / 18.25%
||
7 Day CHG+0.01%
Published-10 Mar, 2026 | 16:48
Updated-17 Mar, 2026 | 16:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
StudioCMS Affected by Privilege Escalation via Insecure API Token Generation

StudioCMS is a server-side-rendered, Astro native, headless content management system. Prior to 0.4.0, the /studiocms_api/dashboard/api-tokens endpoint allows any authenticated user (at least Editor) to generate API tokens for any other user, including owner and admin accounts. The endpoint fails to validate whether the requesting user is authorized to create tokens on behalf of the target user ID, resulting in a full privilege escalation. This vulnerability is fixed in 0.4.0.

Action-Not Available
Vendor-studiocmswithstudiocms
Product-studiocmsstudiocms
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-21286
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.7||HIGH
EPSS-0.27% / 50.02%
||
7 Day CHG~0.00%
Published-01 Feb, 2021 | 15:25
Updated-03 Aug, 2024 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authorization Bypass in AVideo Platform

AVideo Platform is an open-source Audio and Video platform. It is similar to a self-hosted YouTube. In AVideo Platform before version 10.2 there is an authorization bypass vulnerability which enables an ordinary user to get admin control. This is fixed in version 10.2. All queries now remove the pass hash and the recoverPass hash.

Action-Not Available
Vendor-wwbnWWBN
Product-avideoAVideo
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-21389
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.1||HIGH
EPSS-93.30% / 99.81%
||
7 Day CHG~0.00%
Published-26 Mar, 2021 | 20:15
Updated-03 Aug, 2024 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
BuddyPress privilege escalation via REST API

BuddyPress is an open source WordPress plugin to build a community site. In releases of BuddyPress from 5.0.0 before 7.2.1 it's possible for a non-privileged, regular user to obtain administrator rights by exploiting an issue in the REST API members endpoint. The vulnerability has been fixed in BuddyPress 7.2.1. Existing installations of the plugin should be updated to this version to mitigate the issue.

Action-Not Available
Vendor-buddypressbuddypress
Product-buddypressBuddyPress
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-45102
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.34% / 57.00%
||
7 Day CHG~0.00%
Published-16 Dec, 2021 | 04:46
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in HTCondor 9.0.x before 9.0.4 and 9.1.x before 9.1.2. When authenticating to an HTCondor daemon using a SciToken, a user may be granted authorizations beyond what the token should allow.

Action-Not Available
Vendor-wiscn/a
Product-htcondorn/a
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-1539
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.1||HIGH
EPSS-0.29% / 51.92%
||
7 Day CHG~0.00%
Published-04 Jun, 2021 | 16:45
Updated-07 Nov, 2024 | 22:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco ASR 5000 Series Software Authorization Bypass Vulnerabilities

Multiple vulnerabilities in the authorization process of Cisco ASR 5000 Series Software (StarOS) could allow an authenticated, remote attacker to bypass authorization and execute a subset of CLI commands on an affected device. For more information about these vulnerabilities, see the Details section of this advisory.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-starosvirtualized_packet_coreasr_5000asr_5500asr_5700Cisco ASR 5000 Series Software
CWE ID-CWE-863
Incorrect Authorization
CVE-2018-25353
Matching Score-4
Assigner-VulnCheck
ShareView Details
Matching Score-4
Assigner-VulnCheck
CVSS Score-8.7||HIGH
EPSS-Not Assigned
Published-23 May, 2026 | 18:30
Updated-23 May, 2026 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Redaxo CMS Mediapool Addon 5.5.1 Arbitrary File Upload

Redaxo CMS Mediapool Addon 5.5.1 and older contains an arbitrary file upload vulnerability that allows authenticated users to bypass file extension blacklist restrictions. Attackers with editor accounts can upload executable files by using obfuscated extensions like php71 or php53 to evade the blacklist filter and execute arbitrary code.

Action-Not Available
Vendor-Redaxo
Product-Redaxo CMS Mediapool
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-9693
Matching Score-4
Assigner-GitLab Inc.
ShareView Details
Matching Score-4
Assigner-GitLab Inc.
CVSS Score-8.5||HIGH
EPSS-0.08% / 24.46%
||
7 Day CHG~0.00%
Published-14 Nov, 2024 | 11:02
Updated-26 Nov, 2024 | 01:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Incorrect Authorization in GitLab

An issue was discovered in GitLab CE/EE affecting all versions starting from 16.0 prior to 17.3.7, starting from 17.4 prior to 17.4.4, and starting from 17.5 prior to 17.5.2, which could have allowed unauthorized access to the Kubernetes agent in a cluster under specific configurations.

Action-Not Available
Vendor-GitLab Inc.
Product-gitlabGitLab
CWE ID-CWE-863
Incorrect Authorization
CVE-2020-9492
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-8.8||HIGH
EPSS-0.11% / 28.86%
||
7 Day CHG~0.00%
Published-26 Jan, 2021 | 12:55
Updated-04 Aug, 2024 | 10:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Apache Hadoop 3.2.0 to 3.2.1, 3.0.0-alpha1 to 3.1.3, and 2.0.0-alpha to 2.10.0, WebHDFS client might send SPNEGO authorization header to remote URL without proper verification.

Action-Not Available
Vendor-n/aThe Apache Software FoundationOracle Corporation
Product-financial_services_crime_and_compliance_management_studiosolrhadoopApache Hadoop
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-45185
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-7.4||HIGH
EPSS-1.51% / 81.43%
||
7 Day CHG~0.00%
Published-14 Dec, 2023 | 14:04
Updated-02 Aug, 2024 | 20:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
IBM i Access Client Solutions code execution

IBM i Access Client Solutions 1.1.2 through 1.1.4 and 1.1.4.3 through 1.1.9.3 could allow an attacker to execute remote code. Due to improper authority checks the attacker could perform operations on the PC under the user's authority. IBM X-Force ID: 268273.

Action-Not Available
Vendor-IBM Corporation
Product-i_access_client_solutionsi Access Client Solutions
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-43858
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-53.12% / 98.00%
||
7 Day CHG~0.00%
Published-27 Dec, 2021 | 21:20
Updated-04 Aug, 2024 | 04:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
User privilege escalation in MinIO

MinIO is a Kubernetes native application for cloud storage. Prior to version `RELEASE.2021-12-27T07-23-18Z`, a malicious client can hand-craft an HTTP API call that allows for updating policy for a user and gaining higher privileges. The patch in version `RELEASE.2021-12-27T07-23-18Z` changes the accepted request body type and removes the ability to apply policy changes through this API. There is a workaround for this vulnerability: Changing passwords can be disabled by adding an explicit `Deny` rule to disable the API for users.

Action-Not Available
Vendor-miniominio
Product-miniominio
CWE ID-CWE-269
Improper Privilege Management
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-8970
Matching Score-4
Assigner-GitLab Inc.
ShareView Details
Matching Score-4
Assigner-GitLab Inc.
CVSS Score-8.2||HIGH
EPSS-0.07% / 20.63%
||
7 Day CHG~0.00%
Published-11 Oct, 2024 | 12:30
Updated-13 Dec, 2024 | 01:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Incorrect Authorization in GitLab

An issue was discovered in GitLab CE/EE affecting all versions starting from 11.6 prior to 17.2.9, starting from 17.3 prior to 17.3.5, and starting from 17.4 prior to 17.4.2, which allows an attacker to trigger a pipeline as another user under certain circumstances.

Action-Not Available
Vendor-GitLab Inc.
Product-gitlabGitLab
CWE ID-CWE-863
Incorrect Authorization
CVE-2020-4621
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-8.8||HIGH
EPSS-0.38% / 59.84%
||
7 Day CHG~0.00%
Published-22 Sep, 2020 | 13:55
Updated-17 Sep, 2024 | 04:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Data Risk Manager (iDNA) 2.0.6 could allow an authenticated user to escalate their privileges to administrator due to insufficient authorization checks. IBM X-Force ID: 184981.

Action-Not Available
Vendor-IBM Corporation
Product-data_risk_managerData Risk Manager
CWE ID-CWE-863
Incorrect Authorization
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • Next
Details not found