Incorrect Permission Assignment for Critical Resource vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.
Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities.
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction.
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Unquoted Search Path or Element vulnerability in ABB Mint Workbench. A local attacker who successfully exploited this vulnerability could gain elevated privileges by inserting an executable file in the path of the affected service. This issue affects Mint Workbench I versions: from 5866 before 5868.
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.
Incorrect Permission Assignment for Critical Resource, Cleartext Storage of Sensitive Information vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.
This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server.
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
Sensitive Cookie Without 'HttpOnly' Flag vulnerability in ABB REX640 PCL1 (firmware modules), ABB REX640 PCL2 (Firmware modules), ABB REX640 PCL3 (firmware modules) allows Cross-Site Scripting (XSS).This issue affects REX640 PCL1: from 1.0;0 before 1.0.8; REX640 PCL2: from 1.0;0 before 1.1.4; REX640 PCL3: from 1.0;0 before 1.2.1.
Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node.
Dell ThinOS 10, versions prior to 2508_10.0127, contains an Incorrect Permission Assignment for Critical Resource vulnerability. A local low-privileged attacker could potentially exploit this vulnerability leading to Elevation of Privileges and Unauthorized Access.
Adobe Photoshop Elements 8.0 installs the Adobe Active File Monitor V8 service with an insecure security descriptor, which allows local users to (1) stop the service via the stop command, (2) execute arbitrary commands as SYSTEM by using the config command to modify the binPath variable, or (3) restart the service via the start command.
TrustPort Antivirus before 2.8.0.2266 and PC Security before 2.0.0.1291 use weak permissions (Everyone: Full Control) for files under %PROGRAMFILES%, which allows local users to gain privileges by replacing executables with Trojan horse programs.
A vulnerability in the privilege management functionality of all Cisco BroadWorks server types could allow an authenticated, local attacker to elevate privileges to root on an affected system. This vulnerability is due to incorrect implementation of user role permissions. An attacker could exploit this vulnerability by authenticating to the application as a user with the BWORKS or BWSUPERADMIN role and issuing crafted commands on an affected system. A successful exploit could allow the attacker to execute commands beyond the sphere of their intended access level, including initiating installs or running operating system commands with elevated permissions. There are workarounds that address this vulnerability.
RoboDK versions 5.5.3 and prior contain an insecure permission assignment to critical directories vulnerability, which could allow a local user to escalate privileges and write files to the RoboDK process and achieve code execution.
The svpn and policyserver components of the F5 BIG-IP APM client prior to version 7.1.7.1 for Linux and macOS runs as a privileged process and can allow an unprivileged user to get ownership of files owned by root on the local client host. A malicious local unprivileged user may gain knowledge of sensitive information, manipulate certain data, or assume super-user privileges on the local client host.
dp-golang is a Puppet module for Go installations. Prior to 1.2.7, dp-golang could install files — including the compiler binary — with the wrong ownership when Puppet was run as root and the installed package was On macOS: Go version 1.4.3 through 1.21rc3, inclusive, go1.4-bootstrap-20170518.tar.gz, or go1.4-bootstrap-20170531.tar.gz. The user and group specified in Puppet code were ignored for files within the archive. dp-puppet version 1.2.7 will recreate installations if the owner or group of any file or directory within that installation does not match the requested owner or group
The g_file_copy function in glib 2.0 sets the permissions of a target file to the permissions of a symbolic link (777), which allows user-assisted local users to modify files of other users, as demonstrated by using Nautilus to modify the permissions of the user home directory.
An exploitable local privilege elevation vulnerability exists in the file system permissions of GOG Galaxy's “Games” directory, version 1.2.48.36 (Windows 64-bit Installer). An attacker can overwrite executables of installed games to exploit this vulnerability and execute arbitrary code with elevated privileges.
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which could result in local privilege escalation.
An exploitable local privilege escalation vulnerability exists in the privileged helper tool of GOG Galaxy's Games, version 1.2.47 for macOS. An attacker can globally adjust folder permissions leading to execution of arbitrary code with elevated privileges.
An exploitable local privilege elevation vulnerability exists in the file system permissions of GOG Galaxy's install directory. An attacker can overwrite an executable that is launched as a system service on boot by default to exploit this vulnerability and execute arbitrary code with system privileges.
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.
Insecure inherited permissions in some Intel(R) HID Event Filter software installers before version 2.2.2.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
The Canon TR150 print driver through 3.71.2.10 is vulnerable to a privilege escalation issue. During the add printer process, a local attacker can overwrite CNMurGE.dll and, if timed properly, the overwritten DLL will be loaded into a SYSTEM process resulting in escalation of privileges. This occurs because the driver drops a world-writable DLL into a CanonBJ %PROGRAMDATA% location that gets loaded by printisolationhost (a system process).
Insecure inherited permissions in some Flexlm License Daemons for Intel(R) FPGA software before version v11.19.5.0 may allow an authenticated user to potentially enable escalation of privilege via local access.
Insecure permissions in the packaging of tomcat allow local users that win a race during package installation to escalate to root
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an authorized user can write directly to the Scada directory. This may allow privilege escalation.
Insecure inherited permissions in some Intel(R) XTU software before version 7.14.0.15 may allow an authenticated user to potentially enable escalation of privilege via local access.