Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable.
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.
The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext.
The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed).
Unquoted Search Path or Element vulnerability in ABB Mint Workbench. A local attacker who successfully exploited this vulnerability could gain elevated privileges by inserting an executable file in the path of the affected service. This issue affects Mint Workbench I versions: from 5866 before 5868.
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities.
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
Incorrect Permission Assignment for Critical Resource vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product
In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction.
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Insertion of Sensitive Information into Log File vulnerability observed in FLEXON. Some information may be improperly disclosed through https access. This issue affects FLXEON through <= 9.3.4.
Sensitive information leak through log files. The following products are affected: Acronis Agent (Linux, macOS, Windows) before build 35433.
Netskope client is impacted by a vulnerability where an authenticated, local attacker can view sensitive information stored in NSClient logs which should be restricted. The vulnerability exists because the sensitive information is not masked/scrubbed before writing in the logs. A malicious user can use the sensitive information to download data and impersonate another user.
Docker Desktop version 4.3.0 and 4.3.1 has a bug that may log sensitive information (access token or password) on the user's machine during login. This only affects users if they are on Docker Desktop 4.3.0, 4.3.1 and the user has logged in while on 4.3.0, 4.3.1. Gaining access to this data would require having access to the user’s local files.
The issue was resolved by sanitizing logging. This issue is fixed in macOS Sequoia 15.2. An app may be able to access user-sensitive data.
The Snowflake Connector for Python provides an interface for developing Python applications that can connect to Snowflake and perform all standard operations. Prior to version 3.12.3, when the logging level was set by the user to DEBUG, the Connector could have logged Duo passcodes (when specified via the `passcode` parameter) and Azure SAS tokens. Additionally, the SecretDetector logging formatter, if enabled, contained bugs which caused it to not fully redact JWT tokens and certain private key formats. Snowflake released version 3.12.3 of the Snowflake Connector for Python, which fixes the issue. In addition to upgrading, users should review their logs for any potentially sensitive information that may have been captured.
Insertion of Sensitive Information into Log File in Checkmk GmbH's Checkmk versions <2.3.0p22, <2.2.0p37, <2.1.0p50 (EOL) causes remote site secrets to be written to web log files accessible to local site users.
An access-control flaw was found in the OpenStack Orchestration (heat) service before 8.0.0, 6.1.0 and 7.0.2 where a service log directory was improperly made world readable. A malicious system user could exploit this flaw to access sensitive information.
A privacy issue was addressed with improved private data redaction for log entries. This issue is fixed in macOS Ventura 13.6.8, macOS Monterey 12.7.6, iOS 16.7.9 and iPadOS 16.7.9, iOS 17.6 and iPadOS 17.6, macOS Sonoma 14.6. A sandboxed app may be able to access sensitive user data in system logs.
A privacy issue was addressed with improved private data redaction for log entries. This issue is fixed in macOS Ventura 13.7, macOS Sonoma 14.7, macOS Sequoia 15. An app may be able to access user-sensitive data.
A security flaw was found in Ansible Engine, all Ansible 2.7.x versions prior to 2.7.17, all Ansible 2.8.x versions prior to 2.8.11 and all Ansible 2.9.x versions prior to 2.9.7, when managing kubernetes using the k8s module. Sensitive parameters such as passwords and tokens are passed to kubectl from the command line, not using an environment variable or an input configuration file. This will disclose passwords and tokens from process list and no_log directive from debug module would not have any effect making these secrets being disclosed on stdout and log files.
IBM UrbanCode Deploy (UCD) 7.0 through 7.0.5.24, 7.1 through 7.1.2.10, and 7.2 through 7.2.3.13 stores potentially sensitive information in log files that could be read by a local user with access to HTTP request logs.
An issue was discovered in GitLab CE/EE affecting all versions starting from 16.5 prior to 17.1.7, starting from 17.2 prior to 17.2.5, and starting from 17.3 prior to 17.3.2, where dependency proxy credentials are retained in graphql Logs.
An information disclosure issue was addressed with improved private data redaction for log entries. This issue is fixed in tvOS 18.1, iOS 18.1 and iPadOS 18.1, iOS 17.7.1 and iPadOS 17.7.1, macOS Ventura 13.7.1, macOS Sonoma 14.7.1, watchOS 11.1, visionOS 2.1. An app may be able to leak sensitive kernel state.
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
The RSA Identity Governance and Lifecycle software and RSA Via Lifecycle and Governance products prior to 7.1.0 P08 contain an information exposure vulnerability. The Office 365 user password may get logged in a plain text format in the Office 365 connector debug log file. An authenticated malicious local user with access to the debug logs may obtain the exposed password to use in further attacks.
A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions.
When generating QKView of BIG-IP Next instance from the BIG-IP Next Central Manager (CM), F5 iHealth credentials will be logged in the BIG-IP Central Manager logs. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
IBM Sterling Gentran:Server for Microsoft Windows 5.3 stores potentially sensitive information in log files that could be read by a local user. IBM X-Force ID: 213962.
HCL Launch stores potentially sensitive information in log files that could be read by a local user with access to HTTP request logs.
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 SP2). The affected application inserts sensitive information into a log file which is readable by all legitimate users of the underlying system. This could allow an authenticated attacker to compromise the confidentiality of other users' configuration data.
IBM Robotic Process Automation with Automation Anywhere 11 could allow a local user to obtain highly sensitive information from log files when debugging is enabled. IBM X-Force ID: 160765.
IBM Db2 for Linux, UNIX and Windows (includes Db2 Connect Server) 11.5 is vulnerable to an information disclosure vulnerability as sensitive information may be included in a log file under specific conditions.
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain a sensitive information disclosure vulnerability. A local malicious user may exploit this vulnerability to read sensitive information and use it.
A vulnerability was found in ceilometer before version 12.0.0.0rc1. An Information Exposure in ceilometer-agent prints sensitive configuration data to log files without DEBUG logging being activated.