Incorrect Permission Assignment for Critical Resource vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable.
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.
Unquoted Search Path or Element vulnerability in ABB Mint Workbench. A local attacker who successfully exploited this vulnerability could gain elevated privileges by inserting an executable file in the path of the affected service. This issue affects Mint Workbench I versions: from 5866 before 5868.
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities.
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product
In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction.
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server.
Sensitive Cookie Without 'HttpOnly' Flag vulnerability in ABB REX640 PCL1 (firmware modules), ABB REX640 PCL2 (Firmware modules), ABB REX640 PCL3 (firmware modules) allows Cross-Site Scripting (XSS).This issue affects REX640 PCL1: from 1.0;0 before 1.0.8; REX640 PCL2: from 1.0;0 before 1.1.4; REX640 PCL3: from 1.0;0 before 1.2.1.
This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.
Incorrect Permission Assignment for Critical Resource, Cleartext Storage of Sensitive Information vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.
Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node.
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
Quick Emulator (Qemu) built with the VirtFS, host directory sharing via Plan 9 File System(9pfs) support, is vulnerable to an improper access control issue. It could occur while accessing virtfs metadata files in mapped-file security mode. A guest user could use this flaw to escalate their privileges inside guest.
The mm subsystem in the Linux kernel through 3.2 does not properly enforce the CONFIG_STRICT_DEVMEM protection mechanism, which allows local users to read or write to kernel memory locations in the first megabyte (and bypass slab-allocation access restrictions) via an application that opens the /dev/mem file, related to arch/x86/mm/init.c and drivers/char/mem.c.
In Sage 300 ERP (formerly accpac) through 6.8.x, the installer configures the C:\Sage\Sage300\Runtime directory to be the first entry in the system-wide PATH environment variable. However, this directory is writable by unprivileged users because the Sage installer fails to set explicit permissions and therefore inherits weak permissions from the C:\ folder. Because entries in the system-wide PATH variable are included in the search order for DLLs, an attacker could perform DLL search-order hijacking to escalate their privileges to SYSTEM. Furthermore, if the Global Search or Web Screens functionality is enabled, then privilege escalation is possible via the GlobalSearchService and Sage.CNA.WindowsService services, again via DLL search-order hijacking because unprivileged users would have modify permissions on the application directory. Note that while older versions of the software default to installing in %PROGRAMFILES(X86)% (which would allow the Sage folder to inherit strong permissions, making the installation not vulnerable), the official Sage 300 installation guides for those versions recommend installing in C:\Sage, which would make the installation vulnerable.
Bitmask Riseup VPN 0.21.6 contains a local privilege escalation flaw due to improper access controls. When the software is installed with a non-default installation directory off of the system root, the installer fails to properly set ACLs. This allows lower privileged users to replace the VPN executable with a malicious one. When a higher privileged user such as an Administrator launches that executable, it is possible for the lower privileged user to escalate to Administrator privileges.
Zoho Remote Access Plus Server Windows Desktop binary fixed in version 10.1.2132 is affected by an unauthorized password reset vulnerability. Because of the designed password reset mechanism, any non-admin Windows user can reset the password of the Remote Access Plus Server Admin account.
Incorrect Permission Assignment for Critical Resource vulnerability in the crash handling component BDReinit.exe as used in Bitdefender Total Security, Internet Security, Antivirus Plus, Endpoint Security Tools for Windows allows a remote attacker to escalate local privileges to SYSTEM. This issue affects: Bitdefender Total Security versions prior to 26.0.10.45. Bitdefender Internet Security versions prior to 26.0.10.45. Bitdefender Antivirus Plus versions prior to 26.0.10.45. Bitdefender Endpoint Security Tools for Windows versions prior to 7.4.3.146.
Zoho Remote Access Plus Server Windows Desktop Binary fixed from 10.1.2121.1 is affected by incorrect access control. The installation directory is vulnerable to weak file permissions by allowing full control for Windows Everyone user group (non-admin or any guest users), thereby allowing privilege escalation, unauthorized password reset, stealing of sensitive data, access to credentials in plaintext, access to registry values, tampering with configuration files, etc.
An insecure modification vulnerability in the /etc/passwd file was found in all versions of OpenShift ServiceMesh (maistra) before 1.0.8 in the openshift/istio-kialia-rhel7-operator-container. An attacker with access to the container could use this flaw to modify /etc/passwd and escalate their privileges.
ovirt-engine 3.2 running on Linux kernel 3.1 and newer creates certain files world-writeable due to an upstream kernel change which impacted how python's os.chmod() works when passed a mode of '-1'.
For VMware Horizon Client for Windows (5.x and prior before 5.3.0), VMware Remote Console for Windows (10.x before 11.0.0), VMware Workstation for Windows (15.x before 15.5.2) the folder containing configuration files for the VMware USB arbitration service was found to be writable by all users. A local user on the system where the software is installed may exploit this issue to run commands as any user.
In sendLegacyVoicemailNotification of LegacyModeSmsHandler.java, there is a possible permissions bypass due to an unsafe PendingIntent. This could lead to local escalation of privilege with User execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-10 Android-11 Android-12 Android-9Android ID: A-185126319
An issue was discovered in Nagios XI 5.8.5. Insecure file permissions on the nagios_unbundler.py file allow the nagios user to elevate their privileges to the root user.
In sendLegacyVoicemailNotification of LegacyModeSmsHandler.java, there is a possible permissions bypass due to an unsafe PendingIntent. This could lead to local escalation of privilege with User execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-10 Android-11 Android-12 Android-9Android ID: A-185126549
There is an improper security permission configuration vulnerability on ACPU.Successful exploitation of this vulnerability may affect service confidentiality, integrity, and availability.
TrustPort Antivirus before 2.8.0.2266 and PC Security before 2.0.0.1291 use weak permissions (Everyone: Full Control) for files under %PROGRAMFILES%, which allows local users to gain privileges by replacing executables with Trojan horse programs.
Debian-edu-config all versions < 2.11.10, a set of configuration files used for Debian Edu, and debian-lan-config < 0.26, configured too permissive ACLs for the Kerberos admin server, which allowed password changes for other Kerberos user principals.
FOG is a cloning/imaging/rescue suite/inventory management system. The application stores plaintext service account credentials in the "/opt/fog/.fogsettings" file. This file is by default readable by all users on the host. By exploiting these credentials, a malicious user could create new accounts for the web application and much more. The vulnerability is fixed in 1.5.10.41.
The MacOS version of Multipass, version 1.7.0, fixed in 1.7.2, accidentally installed the application directory with incorrect owner.
The Canon TR150 print driver through 3.71.2.10 is vulnerable to a privilege escalation issue. During the add printer process, a local attacker can overwrite CNMurGE.dll and, if timed properly, the overwritten DLL will be loaded into a SYSTEM process resulting in escalation of privileges. This occurs because the driver drops a world-writable DLL into a CanonBJ %PROGRAMDATA% location that gets loaded by printisolationhost (a system process).
Dell EMC PowerScale OneFS versions 8.2.x - 9.2.x contain an incorrect permission assignment for critical resource vulnerability. This could allow a user with ISI_PRIV_LOGIN_SSH or ISI_PRIV_LOGIN_CONSOLE to access privileged information about the cluster.
It was discovered that the installation packages of the Zoom Client for Meetings for MacOS (Standard and for IT Admin) installation before version 5.2.0, Zoom Client Plugin for Sharing iPhone/iPad before version 5.2.0, and Zoom Rooms for Conference before version 5.1.0, copy pre- and post- installation shell scripts to a user-writable directory. In the affected products listed below, a malicious actor with local access to a user's machine could use this flaw to potentially run arbitrary system commands in a higher privileged context during the installation process.