For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product
A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed.
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities.
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine.
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Unquoted Search Path or Element vulnerability in ABB Mint Workbench. A local attacker who successfully exploited this vulnerability could gain elevated privileges by inserting an executable file in the path of the affected service. This issue affects Mint Workbench I versions: from 5866 before 5868.
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database.
Incorrect Permission Assignment for Critical Resource vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.
AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the command queue can use it to launch an attack by running any executable on the AdvaBuild node. The executables that can be run are not limited to AdvaBuild specific executables. Improper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.
An authenticated user might execute malicious code under the user context and take control of the system. S+ Operations or S+ Historian database is affected by multiple vulnerabilities such as the possibility to allow remote authenticated users to gain high privileges.
A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted.
smss.exe debugging subsystem in Windows NT and Windows 2000 does not properly authenticate programs that connect to other programs, which allows local users to gain administrator or SYSTEM privileges by duplicating a handle to a privileged process, as demonstrated by DebPloit.
K7Computing Pvt Ltd K7AntiVirus Premium 15.01.00.53 is affected by: Incorrect Access Control. The impact is: gain privileges (local).
K7Computing Pvt Ltd K7AntiVirus Premium 15.1.0.53 is affected by: Buffer Overflow. The impact is: execute arbitrary code (local). The component is: K7TSMngr.exe.
In setTransactionState of SurfaceFlinger.cpp, there is a possible way to perform tapjacking due to a logic error in the code. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
lightdm before 0.9.6 writes in .dmrc and Xauthority files using root permissions while the files are in user controlled folders. A local user can overwrite root-owned files via a symlink, which can allow possible privilege escalation.
In multiple functions of UserDictionaryProvider.java, there is a possible way to add and delete words in the user dictionary due to a confused deputy. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
In setForceHideNonSystemOverlayWindowIfNeeded of WindowState.java, there is a possible way for message content to be visible on the screensaver while lock screen visibility settings are restricted by the user due to a logic error in the code. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
K7Computing Pvt Ltd K7Antivirus Premium 15.1.0.53 is affected by: Incorrect Access Control. The impact is: Local Process Execution (local). The component is: K7Sentry.sys.
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an improper privilege management vulnerability may allow an authenticated user to modify files when read access should only be given to the user.
An insecure temporary file vulnerability in Palo Alto Networks Traps allows a local authenticated Windows user to escalate privileges or overwrite system files. This issue affects Palo Alto Networks Traps 5.0 versions before 5.0.8; 6.1 versions before 6.1.4 on Windows. This issue does not affect Cortex XDR 7.0. This issue does not affect Traps for Linux or MacOS.
Windows Bluetooth Driver Elevation of Privilege Vulnerability
mount.ecryptfs_private.c in eCryptfs-utils does not validate mount destination filesystem types, which allows local users to gain privileges by mounting over a nonstandard filesystem, as demonstrated by /proc/$pid.
In Platform, there is a possible bypass of user interaction requirements due to missing permission checks. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Product: AndroidVersions: Android-10Android ID: A-73884967
The overlayfs implementation in the Linux kernel through 4.5.2 does not properly maintain POSIX ACL xattr data, which allows local users to gain privileges by leveraging a group-writable setgid directory.
HP has identified a potential vulnerability in BIOS firmware of some Workstation products. Firmware updates are being released to mitigate these potential vulnerabilities.
D-Link DCS-825L firmware v1.08.01 contains a vulnerability in the watchdog script `mydlink-watch-dog.sh`, which blindly respawns binaries such as `dcp` and `signalc` without verifying integrity, authenticity, or permissions. An attacker with local filesystem access (via physical access, firmware modification, or debug interfaces) can replace these binaries with malicious payloads. The script executes these binaries as root in an infinite loop, leading to persistent privilege escalation and arbitrary code execution. This issue is mitigated in v1.09.02, but the product is officially End-of-Life and unsupported.
This vulnerability allows local attackers to escalate privileges on affected installations of Panda Security Free Antivirus 20.2.0.0. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the use of named pipes. The issue results from allowing an untrusted process to impersonate the client of a pipe. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-14208.
K7Computing Pvt Ltd K7AntiVirus Premium 15.1.0.53 is affected by: Incorrect Access Control. The impact is: gain privileges (local). The component is: K7TSMngr.exe.
A vulnerability in the privilege management functionality of all Cisco BroadWorks server types could allow an authenticated, local attacker to elevate privileges to root on an affected system. This vulnerability is due to incorrect implementation of user role permissions. An attacker could exploit this vulnerability by authenticating to the application as a user with the BWORKS or BWSUPERADMIN role and issuing crafted commands on an affected system. A successful exploit could allow the attacker to execute commands beyond the sphere of their intended access level, including initiating installs or running operating system commands with elevated permissions. There are workarounds that address this vulnerability.
A component in Kaspersky Password Manager could allow an attacker to elevate a process Integrity level from Medium to High.
Improper Access Control in Multimedia in Snapdragon Mobile and Snapdragon Wear, Non-standard applications without permission may acquire permission of Qualcomm-specific proprietary intents.