Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2021-23031

Summary
Assigner-f5
Assigner Org ID-9dacffd4-cb11-413f-8451-fbbfd4ddc0ab
Published At-14 Sep, 2021 | 18:07
Updated At-03 Aug, 2024 | 18:58
Rejected At-
Credits

On version 16.0.x before 16.0.1.2, 15.1.x before 15.1.3, 14.1.x before 14.1.4.1, 13.1.x before 13.1.4, 12.1.x before 12.1.6, and 11.6.x before 11.6.5.3, an authenticated user may perform a privilege escalation on the BIG-IP Advanced WAF and ASM Configuration utility. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:f5
Assigner Org ID:9dacffd4-cb11-413f-8451-fbbfd4ddc0ab
Published At:14 Sep, 2021 | 18:07
Updated At:03 Aug, 2024 | 18:58
Rejected At:
▼CVE Numbering Authority (CNA)

On version 16.0.x before 16.0.1.2, 15.1.x before 15.1.3, 14.1.x before 14.1.4.1, 13.1.x before 13.1.4, 12.1.x before 12.1.6, and 11.6.x before 11.6.5.3, an authenticated user may perform a privilege escalation on the BIG-IP Advanced WAF and ASM Configuration utility. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

Affected Products
Vendor
n/a
Product
BIG-IP Advanced WAF and BIG-IP ASM
Versions
Affected
  • 16.0.x before 16.0.1.2, 15.1.x before 15.1.3, 14.1.x before 14.1.4.1, 13.1.x before 13.1.4, 12.1.x before 12.1.6, and 11.6.x before 11.6.5.3
Problem Types
TypeCWE IDDescription
CWECWE-78CWE-78
Type: CWE
CWE ID: CWE-78
Description: CWE-78
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://support.f5.com/csp/article/K41351250
x_refsource_MISC
Hyperlink: https://support.f5.com/csp/article/K41351250
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://support.f5.com/csp/article/K41351250
x_refsource_MISC
x_transferred
Hyperlink: https://support.f5.com/csp/article/K41351250
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:f5sirt@f5.com
Published At:14 Sep, 2021 | 19:15
Updated At:30 Sep, 2021 | 14:42

On version 16.0.x before 16.0.1.2, 15.1.x before 15.1.3, 14.1.x before 14.1.4.1, 13.1.x before 13.1.4, 12.1.x before 12.1.6, and 11.6.x before 11.6.5.3, an authenticated user may perform a privilege escalation on the BIG-IP Advanced WAF and ASM Configuration utility. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.9CRITICAL
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.9
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

F5, Inc.
f5
>>big-ip_advanced_web_application_firewall>>Versions from 11.6.1(inclusive) to 11.6.5.2(inclusive)
cpe:2.3:a:f5:big-ip_advanced_web_application_firewall:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_advanced_web_application_firewall>>Versions from 12.1.0(inclusive) to 12.1.5(inclusive)
cpe:2.3:a:f5:big-ip_advanced_web_application_firewall:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_advanced_web_application_firewall>>Versions from 13.1.0(inclusive) to 13.1.3(inclusive)
cpe:2.3:a:f5:big-ip_advanced_web_application_firewall:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_advanced_web_application_firewall>>Versions from 14.1.0(inclusive) to 14.1.4(inclusive)
cpe:2.3:a:f5:big-ip_advanced_web_application_firewall:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_advanced_web_application_firewall>>Versions from 15.1.0(inclusive) to 15.1.2(inclusive)
cpe:2.3:a:f5:big-ip_advanced_web_application_firewall:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_advanced_web_application_firewall>>Versions from 16.0.0(inclusive) to 16.0.1.1(inclusive)
cpe:2.3:a:f5:big-ip_advanced_web_application_firewall:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_application_security_manager>>Versions from 11.6.1(inclusive) to 11.6.5.2(inclusive)
cpe:2.3:a:f5:big-ip_application_security_manager:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_application_security_manager>>Versions from 12.1.0(inclusive) to 12.1.5(inclusive)
cpe:2.3:a:f5:big-ip_application_security_manager:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_application_security_manager>>Versions from 13.1.0(inclusive) to 13.1.3(inclusive)
cpe:2.3:a:f5:big-ip_application_security_manager:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_application_security_manager>>Versions from 14.1.0(inclusive) to 14.1.4(inclusive)
cpe:2.3:a:f5:big-ip_application_security_manager:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_application_security_manager>>Versions from 15.1.0(inclusive) to 15.1.2(inclusive)
cpe:2.3:a:f5:big-ip_application_security_manager:*:*:*:*:*:*:*:*
F5, Inc.
f5
>>big-ip_application_security_manager>>Versions from 16.0.0(inclusive) to 16.0.1.1(inclusive)
cpe:2.3:a:f5:big-ip_application_security_manager:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-78Primarynvd@nist.gov
CWE-78Secondaryf5sirt@f5.com
CWE ID: CWE-78
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-78
Type: Secondary
Source: f5sirt@f5.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://support.f5.com/csp/article/K41351250f5sirt@f5.com
Mitigation
Vendor Advisory
Hyperlink: https://support.f5.com/csp/article/K41351250
Source: f5sirt@f5.com
Resource:
Mitigation
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

470Records found

CVE-2020-14324
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-9.1||CRITICAL
EPSS-1.13% / 77.42%
||
7 Day CHG~0.00%
Published-11 Aug, 2020 | 13:19
Updated-04 Aug, 2024 | 12:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A high severity vulnerability was found in all active versions of Red Hat CloudForms before 5.11.7.0. The out of band OS command injection vulnerability can be exploited by authenticated attacker while setuping conversion host through Infrastructure Migration Solution. This flaw allows attacker to execute arbitrary commands on CloudForms server.

Action-Not Available
Vendor-n/aRed Hat, Inc.
Product-cloudforms_management_engineCloudForms
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6898
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 18.28%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ in proxy_client.asp os command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-25173
Matching Score-4
Assigner-Jenkins Project
ShareView Details
Matching Score-4
Assigner-Jenkins Project
CVSS Score-8.8||HIGH
EPSS-1.57% / 80.78%
||
7 Day CHG~0.00%
Published-15 Feb, 2022 | 16:10
Updated-03 Aug, 2024 | 04:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Jenkins Pipeline: Groovy Plugin 2648.va9433432b33c and earlier uses the same checkout directories for distinct SCMs when reading the script file (typically Jenkinsfile) for Pipelines, allowing attackers with Item/Configure permission to invoke arbitrary OS commands on the controller through crafted SCM contents.

Action-Not Available
Vendor-Jenkins
Product-pipeline\Jenkins Pipeline: Groovy Plugin
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7597
Matching Score-4
Assigner-Snyk
ShareView Details
Matching Score-4
Assigner-Snyk
CVSS Score-8.8||HIGH
EPSS-0.69% / 70.79%
||
7 Day CHG~0.00%
Published-17 Feb, 2020 | 18:48
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

codecov-node npm module before 3.6.5 allows remote attackers to execute arbitrary commands.The value provided as part of the gcov-root argument is executed by the exec function within lib/codecov.js. This vulnerability exists due to an incomplete fix of CVE-2020-7596.

Action-Not Available
Vendor-codecovn/a
Product-codecovcodecov npm module
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.89% / 74.58%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7596
Matching Score-4
Assigner-Snyk
ShareView Details
Matching Score-4
Assigner-Snyk
CVSS Score-8.8||HIGH
EPSS-1.29% / 78.85%
||
7 Day CHG~0.00%
Published-25 Jan, 2020 | 18:08
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Codecov npm module before 3.6.2 allows remote attackers to execute arbitrary commands via the "gcov-args" argument.

Action-Not Available
Vendor-codecovn/a
Product-nodejs_uploadercodecov npm module
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24390
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.05%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:27
Updated-16 Sep, 2024 | 16:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “remote_text_file” enables an attacker with user level access to the CLI to inject user level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-7752
Matching Score-4
Assigner-Snyk
ShareView Details
Matching Score-4
Assigner-Snyk
CVSS Score-8.8||HIGH
EPSS-3.14% / 86.37%
||
7 Day CHG~0.00%
Published-26 Oct, 2020 | 17:12
Updated-17 Sep, 2024 | 01:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection

This affects the package systeminformation before 4.27.11. This package is vulnerable to Command Injection. The attacker can concatenate curl's parameters to overwrite Javascript files and then execute any OS commands.

Action-Not Available
Vendor-systeminformationn/a
Product-systeminformationsysteminformation
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-6757
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.4||HIGH
EPSS-0.92% / 75.02%
||
7 Day CHG~0.00%
Published-09 Jan, 2020 | 22:10
Updated-04 Aug, 2024 | 09:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

contentHostProperties.php in Rasilient PixelStor 5000 K:4.0.1580-20150629 (KDI Version) allows authenticated attackers to remotely execute code via the name parameter.

Action-Not Available
Vendor-rasilientn/a
Product-pixelstor_5000_firmwarepixelstor_5000n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7788
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.74% / 81.73%
||
7 Day CHG~0.00%
Published-18 Jul, 2025 | 15:02
Updated-22 Jul, 2025 | 13:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Xuxueli xxl-job SampleXxlJob.java commandJobHandler os command injection

A vulnerability has been found in Xuxueli xxl-job up to 3.1.1 and classified as critical. Affected by this vulnerability is the function commandJobHandler of the file src\main\java\com\xxl\job\executor\service\jobhandler\SampleXxlJob.java. The manipulation leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Xuxueli
Product-xxl-job
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-6765
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-0.79% / 72.92%
||
7 Day CHG~0.00%
Published-10 Apr, 2020 | 18:26
Updated-04 Aug, 2024 | 09:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DSL-GS225 J1 AU_1.0.4 devices allow an admin to execute OS commands by placing shell metacharacters after a supported CLI command, as demonstrated by ping -c1 127.0.0.1; cat/etc/passwd. The CLI is reachable by TELNET.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsl-gs225dsl-gs225_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-6682
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-0.95% / 75.44%
||
7 Day CHG~0.00%
Published-13 Jun, 2017 | 06:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the ConfD CLI of Cisco Elastic Services Controllers could allow an authenticated, remote attacker to run arbitrary commands as the Linux tomcat user on an affected system. More Information: CSCvc76620. Known Affected Releases: 2.2(9.76).

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-elastic_services_controllerCisco Elastic Services Controller
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-4512
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-9.1||CRITICAL
EPSS-0.75% / 72.20%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:10
Updated-16 Sep, 2024 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM QRadar SIEM 7.3 and 7.4 could allow a remote privileged user to execute commands.

Action-Not Available
Vendor-IBM Corporation
Product-qradar_security_information_and_event_managerQRadar SIEM
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6619
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 17:31
Updated-27 Jun, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE upgrade.so setUpgradeFW os command injection

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been declared as critical. Affected by this vulnerability is the function setUpgradeFW of the file upgrade.so. The manipulation of the argument FileName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6618
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 17:31
Updated-27 Jun, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE wps.so SetWLanApcliSettings os command injection

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been classified as critical. Affected is the function SetWLanApcliSettings of the file wps.so. The manipulation of the argument PIN leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-2234
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.9||CRITICAL
EPSS-2.01% / 82.96%
||
7 Day CHG-1.27%
Published-24 Aug, 2022 | 15:15
Updated-16 Apr, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
mySCADA myPRO Command Injection

An authenticated mySCADA myPRO 8.26.0 user may be able to modify parameters to run commands directly in the operating system.

Action-Not Available
Vendor-myscadamySCADA Technologies
Product-mypromySCADA myPRO
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-4873
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-7.02% / 91.11%
||
7 Day CHG~0.00%
Published-10 Sep, 2023 | 03:00
Updated-25 Jun, 2025 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Byzoro Smart S45F Multi-Service Secure Gateway Intelligent Management Platform importexport.php os command injection

A vulnerability, which was classified as critical, was found in Byzoro Smart S45F Multi-Service Secure Gateway Intelligent Management Platform up to 20230906. Affected is an unknown function of the file /importexport.php. The manipulation of the argument sql leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-239358 is the identifier assigned to this vulnerability.

Action-Not Available
Vendor-byzoroByzoro
Product-smart_s45fsmart_s45f_firmwareSmart S45F Multi-Service Secure Gateway Intelligent Management Platform
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-2185
Matching Score-4
Assigner-GitLab Inc.
ShareView Details
Matching Score-4
Assigner-GitLab Inc.
CVSS Score-9.9||CRITICAL
EPSS-93.50% / 99.82%
||
7 Day CHG~0.00%
Published-01 Jul, 2022 | 15:50
Updated-03 Aug, 2024 | 00:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A critical issue has been discovered in GitLab affecting all versions starting from 14.0 prior to 14.10.5, 15.0 prior to 15.0.4, and 15.1 prior to 15.1.1 where an authenticated user authorized to import projects could import a maliciously crafted project leading to remote code execution.

Action-Not Available
Vendor-GitLab Inc.
Product-gitlabGitLab
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-26042
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-2.63% / 85.13%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability exists in the daretools binary functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-26518
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-7.10% / 91.17%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability exists in the console infactory_net functionality of InHand Networks InRouter302 V3.5.37. A specially-crafted series of network requests can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-20617
Matching Score-4
Assigner-Jenkins Project
ShareView Details
Matching Score-4
Assigner-Jenkins Project
CVSS Score-8.8||HIGH
EPSS-1.42% / 79.82%
||
7 Day CHG~0.00%
Published-12 Jan, 2022 | 19:05
Updated-03 Aug, 2024 | 02:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Jenkins Docker Commons Plugin 1.17 and earlier does not sanitize the name of an image or a tag, resulting in an OS command execution vulnerability exploitable by attackers with Item/Configure permission or able to control the contents of a previously configured job's SCM repository.

Action-Not Available
Vendor-Jenkins
Product-docker_commonsJenkins Docker Commons Plugin
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6621
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 18:00
Updated-27 Jun, 2025 | 18:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE ap.so QuickSetting os command injection

A vulnerability classified as critical has been found in TOTOLINK CA300-PoE 6.2c.884. This affects the function QuickSetting of the file ap.so. The manipulation of the argument hour/minute leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6620
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 18:00
Updated-27 Jun, 2025 | 18:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE upgrade.so setUpgradeUboot os command injection

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been rated as critical. Affected by this issue is the function setUpgradeUboot of the file upgrade.so. The manipulation of the argument FileName leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6485
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-10.93% / 93.13%
||
7 Day CHG-1.43%
Published-22 Jun, 2025 | 17:00
Updated-14 Aug, 2025 | 20:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK A3002R formWlSiteSurvey os command injection

A vulnerability was found in TOTOLINK A3002R 1.1.1-B20200824.0128. It has been classified as critical. This affects the function formWlSiteSurvey of the file /boafrm/formWlSiteSurvey. The manipulation of the argument wlanif leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-a3002r_firmwarea3002rA3002R
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-6087
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-5.77% / 90.13%
||
7 Day CHG~0.00%
Published-24 Mar, 2017 | 14:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

EyesOfNetwork ("EON") 5.0 and earlier allows remote authenticated users to execute arbitrary code via shell metacharacters in the selected_events[] parameter in the (1) acknowledge, (2) delete, or (3) ownDisown function in module/monitoring_ged/ged_functions.php or the (4) module parameter to module/index.php.

Action-Not Available
Vendor-eonweb_projectn/a
Product-eonwebn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5445
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.24%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 12:31
Updated-10 Jun, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkFWByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this issue is the function RP_checkFWByBBS of the file /goform/RP_checkFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5443
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.24%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 11:31
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection

A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-35789
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.78%
||
7 Day CHG~0.00%
Published-29 Dec, 2020 | 23:40
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR NMS300 devices before 1.6.0.27 are affected by command injection by an authenticated user.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-nms300_firmwarenms300n/a
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-3377
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.3||MEDIUM
EPSS-0.66% / 70.15%
||
7 Day CHG~0.00%
Published-31 Jul, 2020 | 00:00
Updated-13 Nov, 2024 | 18:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Data Center Network Manager Command Injection Vulnerability

A vulnerability in the Device Manager application of Cisco Data Center Network Manager (DCNM) could allow an authenticated, remote attacker to inject arbitrary commands on the affected device. The vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending crafted arguments to a specific field within the application. A successful exploit could allow the attacker to run commands as the administrator on the DCNM.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-data_center_network_managerCisco Data Center Network Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-35714
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.82% / 87.67%
||
7 Day CHG~0.00%
Published-26 Dec, 2020 | 00:46
Updated-04 Aug, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Belkin LINKSYS RE6500 devices before 1.0.11.001 allow remote authenticated users to execute arbitrary commands via goform/systemCommand?command= in conjunction with the goform/pingstart program.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-re6500_firmwarere6500n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5571
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.23%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 05:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemAdmin os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5573
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 36.73%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemWizard setSystemControl os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been rated as critical. Affected by this issue is the function setSystemWizard/setSystemControl of the file /setSystemWizard. The manipulation of the argument AdminID leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5447
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.46%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:31
Updated-02 Jul, 2025 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 ssid1MACFilter os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter. The manipulation of the argument apselect_%d/newap_text_%d leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re6500re9000re6250re6350re7000re9000_firmwarere7000_firmwarere6500_firmwarere6300_firmwarere6350_firmwarere6250_firmwareRE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5440
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.13%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 10:00
Updated-02 Jul, 2025 | 18:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 NTP os command injection

A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function NTP of the file /goform/NTP. The manipulation of the argument manual_year_select/manual_month_select/manual_day_select/manual_hour_select/manual_min_select/manual_sec_select leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24237
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-29.57% / 96.45%
||
7 Day CHG~0.00%
Published-21 Mar, 2022 | 17:24
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The snaptPowered2 component of Snapt Aria v12.8 was discovered to contain a command injection vulnerability. This vulnerability allows authenticated attackers to execute arbitrary commands.

Action-Not Available
Vendor-snaptn/a
Product-arian/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5444
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.24%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 12:00
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection

A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23667
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-1.26% / 78.60%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 20:08
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5446
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.64%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkCredentialsByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2848
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-1.96% / 82.74%
||
7 Day CHG~0.00%
Published-29 Jun, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary shell characters during manual network configuration resulting in command injection. An attacker can simply send an HTTP request to the device to trigger this vulnerability.

Action-Not Available
Vendor-foscamFoscam
Product-c1_indoor_hd_camerac1_indoor_hd_camera_firmwareIndoor IP Camera C1 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2846
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-1.62% / 81.08%
||
7 Day CHG~0.00%
Published-29 Jun, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary shell characters during manual network configuration resulting in command injection. An attacker can simply send an HTTP request to the device to trigger this vulnerability.

Action-Not Available
Vendor-foscamFoscam
Product-c1_indoor_hd_camerac1_indoor_hd_camera_firmwareIndoor IP Camera C1 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-4542
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-92.32% / 99.71%
||
7 Day CHG~0.00%
Published-25 Aug, 2023 | 21:31
Updated-02 Aug, 2024 | 07:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-8000-10 sys1.php os command injection

A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000-10dar-8000-10_firmwareDAR-8000-10
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5442
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.64%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 11:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_pingGatewayByBBS os command injection

A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ip/nm/gw leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5439
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.13%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 09:31
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 verifyFacebookLike os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been rated as critical. Affected by this issue is the function verifyFacebookLike of the file /goform/verifyFacebookLike. The manipulation of the argument uid/accessToken leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2828
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-1.65% / 81.28%
||
7 Day CHG~0.00%
Published-21 Jun, 2017 | 13:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the web management interface used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.37. A specially crafted HTTP request can allow for a user to inject arbitrary shell characters during account creation resulting in command injection. An attacker can simply send an HTTP request to the device to trigger this vulnerability.

Action-Not Available
Vendor-foscamFoscam
Product-c1_indoor_hd_camerac1_indoor_hd_camera_firmwareIndoor IP Camera C1 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24288
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-8.8||HIGH
EPSS-91.64% / 99.67%
||
7 Day CHG~0.00%
Published-25 Feb, 2022 | 08:30
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Apache Airflow: RCE in example DAGs

In Apache Airflow, prior to version 2.2.4, some example DAGs did not properly sanitize user-provided params, making them susceptible to OS Command Injection from the web UI.

Action-Not Available
Vendor-The Apache Software Foundation
Product-airflowApache Airflow
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2843
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-0.28% / 50.75%
||
7 Day CHG~0.00%
Published-27 Jun, 2017 | 15:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In the web management interface in Foscam C1 Indoor HD Camera running application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary data in the "msmtprc" configuration file resulting in command execution. An attacker can simply send an HTTP request to the device to trigger this vulnerability.

Action-Not Available
Vendor-foscamFoscam
Product-c1_indoor_hd_camerac1_indoor_hd_camera_firmwareIndoor IP Camera C1 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-43928
Matching Score-4
Assigner-Synology Inc.
ShareView Details
Matching Score-4
Assigner-Synology Inc.
CVSS Score-9.9||CRITICAL
EPSS-1.06% / 76.75%
||
7 Day CHG~0.00%
Published-07 Feb, 2022 | 02:15
Updated-17 Sep, 2024 | 00:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability in mail sending and receiving component in Synology Mail Station before 20211105-10315 allows remote authenticated users to execute arbitrary commands via unspecified vectors.

Action-Not Available
Vendor-Synology, Inc.
Product-mail_stationMail Station
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2847
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-1.62% / 81.08%
||
7 Day CHG~0.00%
Published-29 Jun, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary shell characters during manual network configuration resulting in command injection. An attacker can simply send an HTTP request to the device to trigger this vulnerability.

Action-Not Available
Vendor-foscamFoscam
Product-c1_indoor_hd_camerac1_indoor_hd_camera_firmwareIndoor IP Camera C1 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5441
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.64%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 10:31
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection

A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2841
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-0.56% / 67.26%
||
7 Day CHG~0.00%
Published-27 Jun, 2017 | 15:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the web management interface used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.37. A specially crafted HTTP request can allow for a user to inject arbitrary data in the "msmtprc" configuration file resulting in command execution. An attacker can simply send an HTTP request to the device to trigger this vulnerability.

Action-Not Available
Vendor-foscamFoscam
Product-c1_indoor_hd_camerac1_indoor_hd_camera_firmwareIndoor IP Camera C1 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • 9
  • 10
  • Next
Details not found