Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2021-30064

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-03 Apr, 2022 | 21:56
Updated At-03 Aug, 2024 | 22:24
Rejected At-
Credits

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:03 Apr, 2022 | 21:56
Updated At:03 Aug, 2024 | 22:24
Rejected At:
▼CVE Numbering Authority (CNA)

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.belden.com/support/security-assurance
x_refsource_MISC
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05
x_refsource_CONFIRM
Hyperlink: https://www.belden.com/support/security-assurance
Resource:
x_refsource_MISC
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.belden.com/support/security-assurance
x_refsource_MISC
x_transferred
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05
x_refsource_CONFIRM
x_transferred
Hyperlink: https://www.belden.com/support/security-assurance
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:03 Apr, 2022 | 22:15
Updated At:09 Apr, 2022 | 00:55

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.06.8MEDIUM
AV:N/AC:M/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.8
Base severity: MEDIUM
Vector:
AV:N/AC:M/Au:N/C:P/I:P/A:P
CPE Matches

belden
belden
>>tofino_xenon_security_appliance_firmware>>Versions before 03.2.03(exclusive)
cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*
belden
belden
>>tofino_xenon_security_appliance>>-
cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-220-tx\/mm_firmware>>-
cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\/mm_firmware:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-220-tx\/mm>>-
cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\/mm:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-220-tx\/tx_firmware>>-
cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\/tx_firmware:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-220-tx\/tx>>-
cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\/tx:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-220-mm\/tx_firmware>>-
cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\/tx_firmware:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-220-mm\/tx>>-
cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\/tx:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-220-mm\/mm_firmware>>-
cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\/mm_firmware:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-220-mm\/mm>>-
cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\/mm:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-100-tx\/tx_firmware>>-
cpe:2.3:o:belden:tofino_argon_fa-tsa-100-tx\/tx_firmware:-:*:*:*:*:*:*:*
belden
belden
>>tofino_argon_fa-tsa-100-tx\/tx>>-
cpe:2.3:h:belden:tofino_argon_fa-tsa-100-tx\/tx:-:*:*:*:*:*:*:*
belden
belden
>>eagle_20_tofino_943_987-505-mm\/mm_firmware>>-
cpe:2.3:o:belden:eagle_20_tofino_943_987-505-mm\/mm_firmware:-:*:*:*:*:*:*:*
belden
belden
>>eagle_20_tofino_943_987-505-mm\/mm>>-
cpe:2.3:h:belden:eagle_20_tofino_943_987-505-mm\/mm:-:*:*:*:*:*:*:*
belden
belden
>>eagle_20_tofino_943_987-504-mm\/tx_firmware>>-
cpe:2.3:o:belden:eagle_20_tofino_943_987-504-mm\/tx_firmware:-:*:*:*:*:*:*:*
belden
belden
>>eagle_20_tofino_943_987-504-mm\/tx>>-
cpe:2.3:h:belden:eagle_20_tofino_943_987-504-mm\/tx:-:*:*:*:*:*:*:*
belden
belden
>>eagle_20_tofino_943_987-502_-tx\/mm_firmware>>-
cpe:2.3:o:belden:eagle_20_tofino_943_987-502_-tx\/mm_firmware:-:*:*:*:*:*:*:*
belden
belden
>>eagle_20_tofino_943_987-502_-tx\/mm>>-
cpe:2.3:h:belden:eagle_20_tofino_943_987-502_-tx\/mm:-:*:*:*:*:*:*:*
belden
belden
>>eagle_20_tofino_943_987-501-tx\/tx_firmware>>-
cpe:2.3:o:belden:eagle_20_tofino_943_987-501-tx\/tx_firmware:-:*:*:*:*:*:*:*
belden
belden
>>eagle_20_tofino_943_987-501-tx\/tx>>-
cpe:2.3:h:belden:eagle_20_tofino_943_987-501-tx\/tx:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tcsefea23f3f20_firmware>>-
cpe:2.3:o:schneider-electric:tcsefea23f3f20_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tcsefea23f3f20>>-
cpe:2.3:h:schneider-electric:tcsefea23f3f20:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tcsefea23f3f21_firmware>>-
cpe:2.3:o:schneider-electric:tcsefea23f3f21_firmware:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tcsefea23f3f21>>-
cpe:2.3:h:schneider-electric:tcsefea23f3f21:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tcsefea23f3f22_firmware>>Versions before 03.23(exclusive)
cpe:2.3:o:schneider-electric:tcsefea23f3f22_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>tcsefea23f3f22>>-
cpe:2.3:h:schneider-electric:tcsefea23f3f22:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-798Primarynvd@nist.gov
CWE ID: CWE-798
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05cve@mitre.org
Vendor Advisory
https://www.belden.com/support/security-assurancecve@mitre.org
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05
Source: cve@mitre.org
Resource:
Vendor Advisory
Hyperlink: https://www.belden.com/support/security-assurance
Source: cve@mitre.org
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

712Records found

CVE-2022-32527
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.61% / 87.33%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32530
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-4.8||MEDIUM
EPSS-0.14% / 34.97%
||
7 Day CHG~0.00%
Published-24 Jun, 2022 | 13:00
Updated-03 Aug, 2024 | 07:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)

Action-Not Available
Vendor-
Product-geo_scada_mobileGeo SCADA Mobile
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2022-32519
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.19% / 41.33%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-257
Storing Passwords in a Recoverable Format
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-32524
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.42% / 88.60%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32514
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.20% / 41.74%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-5500ac2_firmware5500shaclss5500nac5500ac2lss5500shaclss5500nac_firmwarelss5500shac_firmware5500nac_firmware5500nac5500nac25500shac_firmware5500nac2_firmwareClipsal C-Bus Network Automation Controller, 5500NACSpaceLogic C-Bus Network Automation Controller, 5500NAC2Clipsal Wiser for C-Bus Automation Controller, 5500SHACWiser for C-Bus Automation Controller, LSS5500SHACSpaceLogic C-Bus Application Controller, 5500AC2C-Bus Network Automation Controller, LSS5500NAC
CWE ID-CWE-287
Improper Authentication
CVE-2022-32522
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.78% / 87.61%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32523
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.42% / 88.60%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32525
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.61% / 87.33%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32520
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.16% / 37.71%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-32513
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.18% / 40.22%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-5500ac2_firmware5500shaclss5500nac5500ac2lss5500shaclss5500nac_firmwarelss5500shac_firmware5500nac_firmware5500nac5500nac25500shac_firmware5500nac2_firmwareClipsal C-Bus Network Automation Controller, 5500NACSpaceLogic C-Bus Network Automation Controller, 5500NAC2Clipsal Wiser for C-Bus Automation Controller, 5500SHACWiser for C-Bus Automation Controller, LSS5500SHACSpaceLogic C-Bus Application Controller, 5500AC2C-Bus Network Automation Controller, LSS5500NAC
CWE ID-CWE-521
Weak Password Requirements
CVE-2020-7508
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 48.84%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to gain full access by brute force.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (Firmware version 1.5.2 and older)
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2020-7558
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 70.21%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:08
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-30235
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.34% / 55.84%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-16 Sep, 2024 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2020-7560
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.42% / 60.99%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software.

Action-Not Available
Vendor-n/a
Product-unity_proecostruxure_control_expertEcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions)
CWE ID-CWE-123
Write-what-where Condition
CVE-2020-7480
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.57% / 67.66%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:24
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.

Action-Not Available
Vendor-n/a
Product-andover_continuum_9941_firmwareandover_continuum_5720_firmwareandover_continuum_9924andover_continuum_9900_firmwareandover_continuum_5740_firmwareandover_continuum_9940andover_continuum_bcx9640andover_continuum_9702andover_continuum_9900andover_continuum_9924_firmwareandover_continuum_9680andover_continuum_9702_firmwareandover_continuum_9941andover_continuum_bcx9640_firmwareandover_continuum_9940_firmwareandover_continuum_5740andover_continuum_9200_firmwareandover_continuum_bcx4040_firmwareandover_continuum_bcx4040andover_continuum_9200andover_continuum_9680_firmwareandover_continuum_5720Andover Continuum (All versions)
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2020-7512
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 61.81%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:45
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-1103: Use of Platform-Dependent Third Party Components with vulnerabilities vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to exploit the component.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (Firmware version 1.5.2 and older)
CWE ID-CWE-1103
Use of Platform-Dependent Third Party Components
CVE-2023-5402
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 50.58%
||
7 Day CHG~0.00%
Published-04 Oct, 2023 | 17:59
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network.

Action-Not Available
Vendor-Schneider Electric SE
Product-c-bus_toolkitC-Bus Toolkit
CWE ID-CWE-269
Improper Privilege Management
CVE-2020-7552
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.68% / 70.70%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:07
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7561
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.59% / 80.90%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 00:00
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 with firmware 2.7 and older
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7551
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.68% / 70.70%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:07
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7500
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.80% / 73.07%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:21
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89:Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause arbitrary code to be executed when a malicious command is entered.

Action-Not Available
Vendor-n/a
Product-mtn6501-0001_firmwaremtn6260-0310_firmwaremtn6260-0315mtn6260-0415_firmwaremtn6260-0310mtn6501-0002mtn6260-0415mtn6501-0002_firmwaremtn6501-0001mtn6260-0315_firmwaremtn6260-0410mtn6260-0410_firmwareU.motion Servers and Touch Panels (affected versions listed in the security notification)
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2020-7548
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.59% / 68.27%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:45
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.

Action-Not Available
Vendor-n/a
Product-acti9_powertag_linkacti9_smartlink_el_bacti9_smartlink_si_d_firmwareacti9_smartlink_si_b_firmwarewiser_link_firmwarewiser_linkacti9_powertag_link_hdwiser_energywiser_energy_firmwareacti9_smartlink_si_dacti9_powertag_link_firmwareacti9_powertag_link_hd_firmwareacti9_smartlink_si_bacti9_smartlink_el_b_firmwareSmartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)
CWE ID-CWE-330
Use of Insufficiently Random Values
CVE-2020-7553
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 70.21%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:07
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7532
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.43% / 61.55%
||
7 Day CHG~0.00%
Published-16 Sep, 2020 | 15:40
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack x70 Security Administrator (V1.2.0 and prior) which could allow arbitrary code execution when an attacker builds a custom .SDB file containing a malicious serialized buffer.

Action-Not Available
Vendor-n/a
Product-scadapack_x70_security_administratorSCADAPack x70 Security Administrator V1.2.0 and prior.
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2020-7557
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 70.21%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:08
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-125
Out-of-bounds Read
CVE-2020-7534
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.61%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 22:29
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists on the web server used, that could cause a leak of sensitive data or unauthorized actions on the web server during the time the user is logged in. Affected Products: Modicon M340 CPUs: BMXP34 (All Versions), Modicon Quantum CPUs with integrated Ethernet (Copro): 140CPU65 (All Versions), Modicon Premium CPUs with integrated Ethernet (Copro): TSXP57 (All Versions), Modicon M340 ethernet modules: (BMXNOC0401, BMXNOE01, BMXNOR0200H) (All Versions), Modicon Quantum and Premium factory cast communication modules: (140NOE77111, 140NOC78*00, TSXETY5103, TSXETY4103) (All Versions)

Action-Not Available
Vendor-n/a
Product-tsxety4103tsxety5103140cpu65_firmware140noc78000_firmwarebmxnoc0401_firmware140noc78000140noe77111bmxnoe01_firmwarebmxnor0200hmodicon_m340_bmxp342020140cpu65tsxp57tsxety4103_firmwarebmxnoc0401140noe77111_firmwaremodicon_m340_bmxp342020_firmwarebmxnor0200h_firmwarebmxnoe01tsxp57_firmwaretsxety5103_firmwareModicon M340 CPUs: BMXP34 (All Versions), Modicon Quantum CPUs with integrated Ethernet (Copro): 140CPU65 (All Versions), Modicon Premium CPUs with integrated Ethernet (Copro): TSXP57 (All Versions), Modicon M340 ethernet modules: (BMXNOC0401, BMXNOE01, BMXNOR0200H) (All Versions), Modicon Quantum and Premium factory cast communication modules: (140NOE77111, 140NOC78*00, TSXETY5103, TSXETY4103)
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2020-7531
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.18% / 39.36%
||
7 Day CHG~0.00%
Published-16 Sep, 2020 | 15:40
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284 Improper Access Control vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place executables in a specific folder and run code whenever RemoteConnect is executed by the user.

Action-Not Available
Vendor-n/a
Product-scadapack_7x_remote_connectSCADAPack 7x Remote Connect V3.6.3.574 and prior.
CWE ID-CWE-284
Improper Access Control
CVE-2020-7487
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.22% / 44.65%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:50
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.

Action-Not Available
Vendor-n/a
Product-modicon_m241_firmwaremodicon_m218ecostruxure_machine_expertsomachine_motionmodicon_m218_firmwaremodicon_m241somachinemodicon_m258modicon_m258_firmwaremodicon_m251_firmwaremodicon_m251EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)
CWE ID-CWE-345
Insufficient Verification of Data Authenticity
CVE-2020-7485
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 50.54%
||
7 Day CHG~0.00%
Published-15 Apr, 2020 | 21:03
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

**VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy support account in the TriStation software version v4.9.0 and earlier could cause improper access to the TriStation host machine. This was addressed in TriStation version v4.9.1 and v4.10.1 released on May 30, 2013.1

Action-Not Available
Vendor-n/aMicrosoft Corporation
Product-windows_7windows_xpwindows_nttristation_1131TriStation TS1131 (v4.0.0 to v4.9.0, v4.10.0)
CVE-2022-24312
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.75% / 81.80%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7555
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 70.21%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:08
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7493
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.34% / 56.10%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.

Action-Not Available
Vendor-n/a
Product-ecostruxure_operator_terminal_expertEcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2020-7489
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.47% / 63.74%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:15
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.

Action-Not Available
Vendor-n/a
Product-modicon_m200modicon_m100_firmwaremodicon_m221ecostruxure_machine_expertmodicon_m200_firmwaresomachine_basicmodicon_m221_firmwaremodicon_m100SoMachine Basic (all versions)EcoStruxure Machine Expert – Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7522
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 71.83%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 16:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `SoundUploadServlet` which may lead to uploading executable files to non-specified directories.

Action-Not Available
Vendor-n/a
Product-apc_easy_ups_online_softwareSFAPV9601 - APC Easy UPS On-Line Software V2.0 and earlier
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2017-7966
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.97% / 75.77%
||
7 Day CHG~0.00%
Published-07 Jun, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL.

Action-Not Available
Vendor-Schneider Electric SE
Product-somachineSoMachine HVAC Programming Software
CWE ID-CWE-427
Uncontrolled Search Path Element
CVE-2022-24324
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.32% / 84.16%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-24311
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.70% / 87.49%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-22731
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.23% / 45.65%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-22808
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.06% / 17.64%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 00:00
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)

Action-Not Available
Vendor-n/a
Product-hmibscea53d1edb_firmwarehmibscea53d1emlhmibscea53d1edbhmibscea53d1edmhmibscea53d1edm_firmwarehmibscea53d1esm_firmwarehmibscea53d1edlhmibscea53d1ess_firmwarehmibscea53d1eds_firmwarehmibscea53d1edl_firmwarehmibscea53d1eml_firmwarehmibscea53d1esshmibscea53d1esmhmibscea53d1edsEcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2022-26507
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.70% / 90.87%
||
7 Day CHG~0.00%
Published-14 Apr, 2022 | 12:04
Updated-03 Aug, 2024 | 05:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

Action-Not Available
Vendor-attn/a
Product-ecostruxure_process_expertecostruxure_control_expertremoteconnectxmillscadapack_470scadapack_570scadapack_574scadapack_575scadapack_474n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2017-6028
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.23% / 45.72%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m241modicon_m251modicon_m251_firmwaremodicon_m241_firmwareSchneider Electric Modicon PLCs
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-0223
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.23% / 45.68%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-28212
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.40% / 79.64%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:03
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertPLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2020-28215
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.99% / 75.94%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:51
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (firmware 2.7 and older)
CWE ID-CWE-862
Missing Authorization
CVE-2020-28221
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.92% / 75.09%
||
7 Day CHG~0.00%
Published-25 Jan, 2021 | 17:08
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI.

Action-Not Available
Vendor-n/a
Product-st-6400wasp-5600tpsp-5700wcst-6700wahmist6400pro-face_bluehmi_sto_501hmist6200hmi_sto_512st-6500wahmig3xsp-5800wcst-6200wast-6600wasp-5b10hmi_sto_511hmi_sto_531hmist6700hmist6500gp-4105gsp-5600wagp-4106ghmig5u2ecostruxure_operator_terminal_expertgp-4106wsp-5660tphmig5usp-5400wagp-4105whmi_sto_532gp-4107wgp-4104gsp-5b00sp-5500tphmist6600sp-5500wahmig3usp-5700tpsp-5b41gp-4107gsp-5600tagp-4104wEcoStruxure™ Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series
CWE ID-CWE-20
Improper Input Validation
CVE-2022-24310
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.64% / 81.20%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2022-2329
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.09% / 86.27%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2022-22805
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-8.20% / 91.87%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 19:30
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Action-Not Available
Vendor-
Product-scl_series_1036_upssmc_series_1018_ups_firmwaresmtl_series_1026_upsscl_series_1029_ups_firmwaresmt_series_1015_upssmtl_series_1026_ups_firmwarescl_series_1030_ups_firmwaresmt_series_1015_ups_firmwaresmx_series_1031_ups_firmwaresmx_series_1031_upsscl_series_1037_ups_firmwarescl_series_1037_upsscl_series_1036_ups_firmwaresmc_series_1018_upsscl_series_1030_upsscl_series_1029_upsSmartConnect
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-22810
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.30% / 52.96%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)

Action-Not Available
Vendor-n/a
Product-fellerlynkwiser_for_knxspacelynkwiser_for_knx_firmwarefellerlynk_firmwarespacelynk_firmwarespaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2022-22806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.23% / 45.31%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 19:30
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Action-Not Available
Vendor-
Product-scl_series_1036_upssmc_series_1018_ups_firmwaresmtl_series_1026_upsscl_series_1029_ups_firmwaresmt_series_1015_upssmtl_series_1026_ups_firmwarescl_series_1030_ups_firmwaresmt_series_1015_ups_firmwaresmx_series_1031_ups_firmwaresmx_series_1031_upsscl_series_1037_ups_firmwarescl_series_1037_upsscl_series_1036_ups_firmwaresmc_series_1018_upsscl_series_1030_upsscl_series_1029_upsSmartConnect
CWE ID-CWE-294
Authentication Bypass by Capture-replay