Vulnerability Details :

CVE-2020-28215

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-11 Dec, 2020 | 00:51
Updated At-04 Aug, 2024 | 16:33
Rejected At-
Credits

A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:11 Dec, 2020 | 00:51
Updated At:04 Aug, 2024 | 16:33
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently.

Affected Products
Vendor
n/a
Product
Easergy T300 (firmware 2.7 and older)
Versions
Affected
  • Easergy T300 (firmware 2.7 and older)
Problem Types
TypeCWE IDDescription
CWECWE-862CWE-862: Missing Authorization
Type: CWE
CWE ID: CWE-862
Description: CWE-862: Missing Authorization
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-315-06/
x_refsource_CONFIRM
https://us-cert.cisa.gov/ics/advisories/icsa-20-343-03
x_refsource_MISC
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-315-06/
Resource:
x_refsource_CONFIRM
Hyperlink: https://us-cert.cisa.gov/ics/advisories/icsa-20-343-03
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.se.com/ww/en/download/document/SEVD-2020-315-06/
x_refsource_CONFIRM
x_transferred
https://us-cert.cisa.gov/ics/advisories/icsa-20-343-03
x_refsource_MISC
x_transferred
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-315-06/
Resource:
x_refsource_CONFIRM
x_transferred
Hyperlink: https://us-cert.cisa.gov/ics/advisories/icsa-20-343-03
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:11 Dec, 2020 | 01:15
Updated At:14 Dec, 2020 | 14:46

A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.07.5HIGH
AV:N/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 7.5
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Schneider Electric SE
schneider-electric
>>easergy_t300>>-
cpe:2.3:h:schneider-electric:easergy_t300:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>easergy_t300_firmware>>Versions up to 2.7(inclusive)
cpe:2.3:o:schneider-electric:easergy_t300_firmware:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-862Primarycybersecurity@se.com
CWE ID: CWE-862
Type: Primary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://us-cert.cisa.gov/ics/advisories/icsa-20-343-03cybersecurity@se.com
Third Party Advisory
https://www.se.com/ww/en/download/document/SEVD-2020-315-06/cybersecurity@se.com
Vendor Advisory
Hyperlink: https://us-cert.cisa.gov/ics/advisories/icsa-20-343-03
Source: cybersecurity@se.com
Resource:
Third Party Advisory
Hyperlink: https://www.se.com/ww/en/download/document/SEVD-2020-315-06/
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

512Records found

CVE-2024-10575
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-10||CRITICAL
EPSS-0.62% / 46.20%
||
7 Day CHG~0.00%
Published-13 Nov, 2024 | 04:35
Updated-19 Nov, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on the network and potentially impacting connected devices.

Action-Not Available
Vendor-
Product-ecostruxure_it_gatewayEcoStruxure IT Gatewayecostruxure_it_gateway
CWE ID-CWE-862
Missing Authorization
CVE-2021-22763
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.84% / 76.78%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 14:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_pm5562powerlogic_pm8eccpowerlogic_pm5560powerlogic_pm5560_firmwarepowerlogic_pm5562_firmwarepowerlogic_pm5563_firmwarepowerlogic_pm5563powerlogic_pm8ecc_firmwarepowerlogic_pm5561_firmwarepowerlogic_pm5561PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation)
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2021-22765
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.71% / 84.40%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_egx300_firmwarepowerlogic_egx100_firmwarepowerlogic_egx100powerlogic_egx300PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22768
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.71% / 84.40%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_egx300_firmwarepowerlogic_egx100_firmwarepowerlogic_egx100powerlogic_egx300PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22767
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.71% / 84.40%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_egx300_firmwarepowerlogic_egx100_firmwarepowerlogic_egx100powerlogic_egx300PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22820
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.08% / 61.72%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evp2pe_firmwareevlink_parking_evf2_firmwareevlink_parking_evw2evlink_parking_evp2peevlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_city_evc1s7p4n/a
CWE ID-CWE-613
Insufficient Session Expiration
CVE-2021-22803
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.94% / 78.02%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2021-22730
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.36% / 68.75%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:44
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2021-22795
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-3.08% / 86.31%
||
7 Day CHG~0.00%
Published-28 Mar, 2022 | 16:25
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-22714
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.43% / 82.50%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:13
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.

Action-Not Available
Vendor-n/a
Product-powerlogic_ion9000_firmwarepowerlogic_pm8000_firmwarepowerlogic_pm8000powerlogic_ion9000powerlogic_ion7400_firmwarepowerlogic_ion7400PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22794
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-2.08% / 79.57%
||
7 Day CHG~0.00%
Published-28 Mar, 2022 | 16:25
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22727
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.40% / 69.72%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:43
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized access to the charging station web server

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-331
Insufficient Entropy
CVE-2021-22738
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.63% / 46.53%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access when credentials are discovered after a brute force attack.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-327
Use of a Broken or Risky Cryptographic Algorithm
CVE-2021-22707
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-64.61% / 99.16%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2021-22737
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.95% / 57.53%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 00:00
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2020-7508
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 70.28%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to gain full access by brute force.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (Firmware version 1.5.2 and older)
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2020-7522
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.66% / 74.19%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 16:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `SoundUploadServlet` which may lead to uploading executable files to non-specified directories.

Action-Not Available
Vendor-n/a
Product-apc_easy_ups_online_softwareSFAPV9601 - APC Easy UPS On-Line Software V2.0 and earlier
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7512
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 70.26%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:45
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-1103: Use of Platform-Dependent Third Party Components with vulnerabilities vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to exploit the component.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (Firmware version 1.5.2 and older)
CWE ID-CWE-1103
Use of Platform-Dependent Third Party Components
CVE-2020-7475
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.54% / 72.31%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 18:56
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertmodicon_m580_firmwareunity_promodicon_m340modicon_m340_firmwaremodicon_m580EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7487
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.68% / 48.38%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:50
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.

Action-Not Available
Vendor-n/a
Product-modicon_m241_firmwaremodicon_m218ecostruxure_machine_expertsomachine_motionmodicon_m218_firmwaremodicon_m241somachinemodicon_m258modicon_m258_firmwaremodicon_m251_firmwaremodicon_m251EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)
CWE ID-CWE-345
Insufficient Verification of Data Authenticity
CVE-2020-7497
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.29% / 81.39%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:13
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts.

Action-Not Available
Vendor-n/a
Product-ecostruxure_operator_terminal_expertEcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7498
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.36% / 68.75%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:15
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results.

Action-Not Available
Vendor-n/a
Product-os_loaderunity_loaderUnity Loader and OS Loader Software (All versions)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2020-7480
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.50% / 71.54%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 19:24
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.

Action-Not Available
Vendor-n/a
Product-andover_continuum_9941_firmwareandover_continuum_5720_firmwareandover_continuum_9924andover_continuum_9900_firmwareandover_continuum_5740_firmwareandover_continuum_9940andover_continuum_bcx9640andover_continuum_9702andover_continuum_9900andover_continuum_9924_firmwareandover_continuum_9680andover_continuum_9702_firmwareandover_continuum_9941andover_continuum_bcx9640_firmwareandover_continuum_9940_firmwareandover_continuum_5740andover_continuum_9200_firmwareandover_continuum_bcx4040_firmwareandover_continuum_bcx4040andover_continuum_9200andover_continuum_9680_firmwareandover_continuum_5720Andover Continuum (All versions)
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2020-7489
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.56% / 72.58%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:15
Updated-28 May, 2026 | 21:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m100_firmwaremodicon_m221_firmwaremodicon_m221modicon_m100somachine_basicmodicon_m200ecostruxure_machine_expertmodicon_m200_firmwareSoMachine Basic (all versions)EcoStruxure Machine Expert – Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-7548
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.43% / 70.16%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:45
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.

Action-Not Available
Vendor-n/a
Product-acti9_powertag_linkacti9_smartlink_el_bacti9_smartlink_si_d_firmwareacti9_smartlink_si_b_firmwarewiser_link_firmwarewiser_linkacti9_powertag_link_hdwiser_energywiser_energy_firmwareacti9_smartlink_si_dacti9_powertag_link_firmwareacti9_powertag_link_hd_firmwareacti9_smartlink_si_bacti9_smartlink_el_b_firmwareSmartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)
CWE ID-CWE-330
Use of Insufficiently Random Values
CVE-2020-7533
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.24% / 80.98%
||
7 Day CHG-0.06%
Published-01 Dec, 2020 | 14:47
Updated-10 Jun, 2025 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-140noc78000tsxp574634_firmwaretsxp574634140cpu65260_firmwaretsxety4103tsxp575634modicon_m340_bmxp342000modicon_m340_bmxp3420302_firmwarebmxnoe0100modicon_m340_bmxp342000_firmwarebmxnoe0110_firmwaretsxety5103_firmwaretsxp576634140noe77111_firmwaremodicon_m340_bmxp341000modicon_m340_bmxp3420102_firmwaremodicon_m340_bmxp341000_firmwarebmxnoe0110tsxp575634_firmware140noe77111bmxnoe0100_firmwarebmxnoc0401_firmware140noc77101140cpu65260bmxnoc0401140noc77101_firmwaretsxety4103_firmwaremodicon_m340_bmxp3420302140noc78000_firmwaretsxp576634_firmwaremodicon_m340_bmxp3420102tsxety5103Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see security notification for version information)
CWE ID-CWE-287
Improper Authentication
CVE-2020-7540
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.22% / 80.82%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmware140cpu65160_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmwarebmxnor200h_firmware140noc78100_firmwaremodicon_m340_bmxp342000140cpu65160modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110140noe77101tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302140noe77101_firmwaremodicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnor200htsxp576634_firmwarebmxnoc0401modicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7485
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.81% / 76.39%
||
7 Day CHG~0.00%
Published-15 Apr, 2020 | 21:03
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

**VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy support account in the TriStation software version v4.9.0 and earlier could cause improper access to the TriStation host machine. This was addressed in TriStation version v4.9.1 and v4.10.1 released on May 30, 2013.1

Action-Not Available
Vendor-n/aMicrosoft Corporation
Product-windows_7windows_xpwindows_nttristation_1131TriStation TS1131 (v4.0.0 to v4.9.0, v4.10.0)
CVE-2019-6824
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.46% / 90.44%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:44
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Action-Not Available
Vendor-Schneider Electric SE
Product-proclimaProClima all versions prior to version 8.0.0
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-32518
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.53% / 41.71%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2018-7836
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-31.98% / 98.13%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files.

Action-Not Available
Vendor-
Product-iiot_monitorIIoT Monitor 3.1.38
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2018-1126
Matching Score-8
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-8
Assigner-Red Hat, Inc.
CVSS Score-4.8||MEDIUM
EPSS-1.99% / 78.58%
||
7 Day CHG~0.00%
Published-23 May, 2018 | 13:00
Updated-17 Dec, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124.

Action-Not Available
Vendor-procps-ng_project[UNKNOWN]Red Hat, Inc.Debian GNU/LinuxCanonical Ltd.
Product-enterprise_linux_serverubuntu_linuxdebian_linuxprocps-ngenterprise_linux_server_ausenterprise_linux_workstationenterprise_linuxenterprise_linux_server_tusenterprise_linux_desktopstruxureware_data_center_expertprocps-ng, procps
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2017-9957
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.62% / 73.51%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2017-9629
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-9.79% / 95.04%
||
7 Day CHG~0.00%
Published-07 Jul, 2017 | 17:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_archestra_loggerSchneider Electric Wonderware ArchestrA Logger
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2017-7689
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.53% / 91.98%
||
7 Day CHG~0.00%
Published-11 Apr, 2017 | 21:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-homelynk_controller_lss100100homelynk_controller_lss100100_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-7973
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.47% / 71.05%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls to various paths allowing performance of arbitrary SQL commands against the underlying database.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2017-7974
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.61% / 90.70%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A path traversal information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can execute arbitrary code and exfiltrate files.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2017-7575
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.98% / 89.42%
||
7 Day CHG~0.00%
Published-06 Apr, 2017 | 21:00
Updated-29 May, 2026 | 14:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_tm221ce16r_firmwaremodicon_tm221ce16rn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2017-7574
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-10||CRITICAL
EPSS-1.24% / 66.10%
||
7 Day CHG~0.00%
Published-06 Apr, 2017 | 21:00
Updated-29 May, 2026 | 14:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_tm221ce16r_firmwaremodicon_tm221ce16rsomachinen/a
CWE ID-CWE-321
Use of Hard-coded Cryptographic Key
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2024-6407
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 34.86%
||
7 Day CHG~0.00%
Published-11 Jul, 2024 | 09:07
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Action-Not Available
Vendor-
Product-whc-5918awhc-5918a_firmwareWiser Home Controller WHC-5918A
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2012-0931
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.92% / 91.21%
||
7 Day CHG~0.00%
Published-28 Jan, 2012 | 01:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_quantum_plcn/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-6028
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-2.25% / 81.06%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m241modicon_m251_firmwaremodicon_m241_firmwaremodicon_m251Schneider Electric Modicon PLCs
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2017-6034
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-5.14% / 91.53%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-04 Jun, 2026 | 22:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.

Action-Not Available
Vendor-Schneider Electric SE
Product-modbus_firmwaremodbusModicon Modbus Protocol
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2023-29412
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.22% / 65.59%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:50
Updated-05 Feb, 2025 | 21:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-5155
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.3||HIGH
EPSS-1.66% / 74.18%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_historianSchneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2024-37036
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.53% / 41.64%
||
7 Day CHG~0.00%
Published-12 Jun, 2024 | 16:48
Updated-14 Aug, 2024 | 14:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.

Action-Not Available
Vendor-
Product-sage_4400sage_1410sage_3030_magnumsage_2400sage_rtu_firmwaresage_1450sage_1430Sage 4400Sage 1450Sage 1410Sage 3030 MagnumSage 1430Sage 2400sage_4400_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-25549
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-1.18% / 64.46%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:35
Updated-03 Mar, 2025 | 19:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2023-25550
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-1.18% / 64.46%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:36
Updated-12 Feb, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2022-46680
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.38% / 30.38%
||
7 Day CHG~0.00%
Published-22 May, 2023 | 13:25
Updated-21 Jan, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.

Action-Not Available
Vendor-Schneider Electric SE
Product-powerlogic_ion8650powerlogic_ion9000_firmwarepowerlogic_ion9000powerlogic_pm8000powerlogic_pm8000_firmwarepowerlogic_ion7400_firmwarepowerlogic_ion8800_firmwarepowerlogic_ion8800powerlogic_ion7400powerlogic_ion8650_firmwarePowerLogic ION9000PowerLogic ION8800Legacy ION products PowerLogic PM8000PowerLogic ION7400PowerLogic ION8650
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2022-45789
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.1||HIGH
EPSS-1.44% / 70.46%
||
7 Day CHG~0.00%
Published-31 Jan, 2023 | 00:00
Updated-29 May, 2026 | 14:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)

Action-Not Available
Vendor-Schneider Electric SE
Product-modicon_m340_bmxp342030_firmwaremodicon_m340_bmxp3420302h_firmwaremodicon_m340_bmxp342020h_firmwaremodicon_m580_bmep583040_firmwaremodicon_m580_bmeh582040smodicon_m340_bmxp3420302_firmwaremodicon_m340_bmxp342010modicon_m580_bmeh584040smodicon_m580_bmep582020h_firmwaremodicon_m580_bmep584040s_firmwaremodicon_m580_bmep584040modicon_m340_bmxp342010_firmwaremodicon_m340_bmxp342020_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep582040h_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep584040smodicon_m580_bmeh582040cmodicon_m580_bmep583040ecostruxure_control_expertmodicon_m580_bmep582040modicon_m580_bmep584020_firmwaremodicon_m580_bmep585040modicon_m580_bmep585040c_firmwaremodicon_m580_bmeh584040modicon_m580_bmeh584040_firmwaremodicon_m580_bmep581020h_firmwaremodicon_m580_bmep584020modicon_m580_bmeh584040s_firmwaremodicon_m340_bmxp342020modicon_m580_bmep582040smodicon_m340_bmxp342030hmodicon_m340_bmxp342020hmodicon_m580_bmep582020_firmwaremodicon_m580_bmeh586040cmodicon_m340_bmxp342000_firmwaremodicon_m580_bmep581020hmodicon_m580_bmeh586040_firmwaremodicon_m580_bmeh584040cmodicon_m340_bmxp342030modicon_m580_bmeh586040c_firmwaremodicon_m580_bmeh582040_firmwaremodicon_m580_bmep586040_firmwaremodicon_m580_bmep582040_firmwaremodicon_m580_bmeh582040modicon_m580_bmeh582040c_firmwaremodicon_m580_bmep583020modicon_m580_bmeh586040s_firmwaremodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_m340_bmxp342000modicon_m580_bmeh586040modicon_m580_bmep582020modicon_m580_bmep583020_firmwaremodicon_m340_bmxp341000modicon_m580_bmeh584040c_firmwaremodicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_m580_bmep582040hmodicon_m340_bmxp3420302modicon_m580_bmep582040s_firmwaremodicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwareecostruxure_process_expertmodicon_m580_bmep581020modicon_m580_bmep586040cmodicon_m340_bmxp342030h_firmwaremodicon_m580_bmep582020hmodicon_m580_bmep586040c_firmwaremodicon_m340_bmxp3420102modicon_m580_bmeh582040s_firmwareModicon M580 CPU (part numbers BMEP* and BMEH*) Modicon M340 CPU (part numbers BMXP34*)EcoStruxure Control Expert Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)EcoStruxure Process Expert
CWE ID-CWE-294
Authentication Bypass by Capture-replay