SQL injection vulnerability in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to execute arbitrary SQL commands via a malformed URL.
Advantech R-SeeNet v2.4.23 allows an unauthenticated remote attacker to read from and write to the snmpmon.ini file, which contains sensitive information.
SQL injection vulnerability in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to execute arbitrary SQL commands via crafted string input.
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.
WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack.
The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code.
The affected product is vulnerable to directory traversal, which may allow an attacker to access unauthorized files and execute arbitrary code.
An Improper Authentication issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Specially crafted requests allow a possible authentication bypass that could allow remote code execution.
Advantech WebAccess 8.3.1 and earlier has a path traversal vulnerability which may allow an attacker to execute arbitrary code.
Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code.
The affected product’s configuration is vulnerable due to missing authentication, which may allow an attacker to change configurations and execute arbitrary code on the iView (versions prior to v5.7.03.6182).
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a path transversal vulnerability has been identified, which may allow an attacker to execute arbitrary code.
Advantech iView versions prior to v5.7.03.6112 are vulnerable to a SQL injection, which may allow an attacker to escalate privileges to 'Administrator'.
Access to the Advantech iView versions prior to v5.7.03.6112 configuration are missing authentication, which may allow an unauthorized attacker to change the configuration and obtain code execution.
An OS Command Injection vulnerability exists in the ping.php script functionality of Advantech R-SeeNet v 2.4.12 (20.10.2020). A specially crafted HTTP request can lead to arbitrary OS command execution. An attacker can send a crafted HTTP request to trigger this vulnerability.
Advantech Spectre RT ERT351 Versions 5.1.3 and prior has insufficient login authentication parameters required for the web application may allow an attacker to gain full access using a brute-force password attack.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
An issue was discovered in Advantech WebAccess Version 8.1. To be able to exploit the SQL injection vulnerability, an attacker must supply malformed input to the WebAccess software. Successful attack could result in administrative access to the application and its data files.
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. Path traversal vulnerabilities are caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage these vulnerabilities to remotely execute code while posing as an administrator.
In WebAccess versions 8.4.1 and prior, an exploit executed over the network may cause improper control of generation of code, which may allow remote code execution, data exfiltration, or cause a system crash.
In WebAccess, versions 8.4.1 and prior, an improper authorization vulnerability may allow an attacker to disclose sensitive information, cause improper control of generation of code, which may allow remote code execution or cause a system crash.
In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991.
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.
In WebAccess/SCADA Versions 8.3.5 and prior, multiple untrusted pointer dereference vulnerabilities may allow a remote attacker to execute arbitrary code.
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a heap-based buffer overflow vulnerability has been identified, which may allow an attacker to execute arbitrary code.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
Stack-based buffer overflow in Advantech WebAccess before 7.2 allows remote attackers to execute arbitrary code via a long NodeName parameter.
WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data.
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution.
WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands.
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a stack-based buffer overflow, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
In Advantech WebAccess, Versions 8.4.2 and prior. A stack-based buffer overflow vulnerability caused by a lack of proper validation of the length of user-supplied data may allow remote code execution.
Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stack-based Buffer Overflow vulnerability, which can be triggered by authenticated users via a crafted POST request.
In WebAccess versions 8.4.1 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
A Stack-based Buffer Overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. The application lacks proper validation of the length of user-supplied data prior to copying it to a stack-based buffer, which could allow an attacker to execute arbitrary code under the context of the process.
WebAccess Versions 8.3.2 and prior. The application fails to properly validate the length of user-supplied data, causing a buffer overflow condition that allows for arbitrary remote code execution.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formGetIptv.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR R6400, R6700, R7000, R7850, R7900, R8000, RS400, and XR300 routers with firmware 1.0.4.84_10.0.58. Authentication is not required to exploit this vulnerability. The specific flaw exists within the check_ra service. A crafted raePolicyVersion in a RAE_Policy.json file can trigger an overflow of a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-9852.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function setIptvInfo.
The HTTPD binary in multiple ZTE routers has a stack-based buffer overflow vulnerability in check_data_integrity function. This function is responsible for validating the checksum of data in post request. The checksum is sent encrypted in the request, the function decrypts it and stores the checksum on the stack without validating it. An unauthenticated attacker can get RCE as root by exploiting this vulnerability.
Stack-based Buffer Overflow vulnerability in the ONVIF server component of Victure PC420 smart camera allows an attacker to execute remote code on the target device. This issue affects: Victure PC420 firmware version 1.2.2 and prior versions.
The HTTPD binary in multiple ZTE routers has a stack-based buffer overflow vulnerability in webPrivateDecrypt function. This function is responsible for decrypting RSA encrypted ciphertext, the encrypted data is supplied base64 encoded. The decoded ciphertext is stored on the stack without checking its length. An unauthenticated attacker can get RCE as root by exploiting this vulnerability.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the serverName parameter in the function form_fast_setting_internet_set.
Memory corruption in WLAN Firmware while doing a memory copy of pmk cache.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formGetIptv.
An issue was discovered in Mbed TLS 3.6 before 3.6.1. A stack buffer overflow in mbedtls_ecdsa_der_to_raw() and mbedtls_ecdsa_raw_to_der() can occur when the bits parameter is larger than the largest supported curve. In some configurations with PSA disabled, all values of bits are affected. (This never happens in internal library calls, but can affect applications that call these functions directly.)