A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially crafted event actions. Affected Product: ConneXium Network Manager Software (All Versions)
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized access to the charging station web server
Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.
Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when authentication is bypassed.
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI.
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution.
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.
A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.
A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC.
A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.
A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed.
A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors.
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause exposure of credentials when attacker has access to application on network over http
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.
CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)
A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.
CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)