D-Link DIR-605L Hardware Revision B2 (End-of-Life, EOL) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn76_dlwbr_dir605L" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) use undocumented accounts.
Arbitrary code execution vlnerability in Operation bridge Manager, Application Performance Management and Operations Bridge (containerized) vulnerability in Micro Focus products products Operation Bridge Manager, Operation Bridge (containerized) and Application Performance Management. The vulneravility affects: 1.) Operation Bridge Manager versions 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, 10.63,10.62, 10.61, 10.60, 10.12, 10.11, 10.10 and all earlier versions. 2.) Operations Bridge (containerized) 2020.05, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05. 2018.02 and 2017.11. 3.) Application Performance Management versions 9,51, 9.50 and 9.40 with uCMDB 10.33 CUP 3. The vulnerability could allow Arbitrary code execution.
An authentication bypass vulnerability exists in the web interface /action/factory* functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP header can lead to authentication bypass. An attacker can send an HTTP request to trigger this vulnerability.
D-Link DIR-600L Hardware Revision B1 (End-of-Life) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn61_dlwbr_dir600L" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches.
Snap One WattBox 800 and 820 series firmware versions prior to 2.10.0.0 contain undisclosed diagnostic HTTP endpoints that require only the device MAC address and service tag for authentication, both of which are printed in plaintext on the physical device label. Attackers with access to the device label or documentation containing these values can authenticate to the several endpoints and execute arbitrary commands as root on the device.
A security issue was discovered in the Kubernetes Image Builder versions <= v0.1.37 where default credentials are enabled during the image build process. Virtual machine images built using the Proxmox provider do not disable these default credentials, and nodes using the resulting images may be accessible via these default credentials. The credentials can be used to gain root access. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project with its Proxmox provider.
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain SuperUser access to the device.
USR IOT 4G LTE Industrial Cellular VPN Router v1.0.36 was discovered to contain hard-coded credentials for its highest privileged account. The credentials cannot be altered through normal operation of the device.
Rakuten Casa version AP_F_V1_4_1 or AP_F_V2_0_0 uses a hard-coded credential which may allow a remote unauthenticated attacker to log in with the root privilege and perform an arbitrary operation.
The optional Web Screens and Global Search features for Sage 300 through version 2022 use a hard-coded 40-byte blowfish key ("LandlordPassKey") to encrypt and decrypt secrets stored in configuration files and in database tables.
The Jitsi Meet (aka docker-jitsi-meet) stack on Docker before stable-4384-1 uses default passwords (such as passw0rd) for system accounts.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.
INPRAX "iZZi connect" application on Android contains hard-coded MQTT queue credentials. The same MQTT queue is used by corresponding physical recuperation devices. Exploiting this vulnerability could potentially allow unauthorized access to manage and read parameters of the recuperation unit "reQnet iZZi".This issue affects "iZZi connect" application versions before 2024010401.
Hardcoded admin token in SoundBar apps in Linkplay SDK 1.00 allows remote attackers to gain admin privilege access in linkplay antifactory
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. During the installation, it sets up administrative access by default with the account admin and password 0000. After the installation, users/admins are not prompted to change this password.
Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.
Calibre-Web 0.6.6 allows authentication bypass because of the 'A0Zr98j/3yX R~XHH!jmN]LWX/,?RT' hardcoded secret key.
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.
Anevia Flamingo XL/XS 3.6.20 contains a critical vulnerability with weak default administrative credentials that can be easily guessed. Attackers can leverage these hard-coded credentials to gain full remote system control without complex authentication mechanisms.
An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
A CWE-798 “Use of Hard-coded Credentials” vulnerability in the MariaDB database of the web application allows a remote unauthenticated attacker to access the database service and all included data with the same privileges of the web application. This issue affects: AiLux imx6 bundle below version imx6_1.0.7-2.
ZyXEL ZyWALL 1050 has a hard-coded password for the Quagga and Zebra processes that is not changed when it is set by a user, which allows remote attackers to gain privileges.
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network.
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
DoraCMS 2.1.8 is vulnerable to Use of Hard-coded Cryptographic Key.
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00
Home Owners Collection Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel.
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.
Bettini Srl GAMS Product Line v4.3.0 was discovered to re-use static SSH keys across installations, allowing unauthenticated attackers to login as root users via extracting a key from the software.
OpsRamp Gateway before 7.0.0 has a backdoor account vadmin with the password 9vt@f3Vt that allows root SSH access to the server. This issue has been resolved in OpsRamp Gateway firmware version 7.0.0 where an administrator and a system user accounts are the only available user accounts for the gateway appliance.
Certain switch models from PLANET Technology have a Hard-coded community string in the SNMPv1 service, allowing unauthorized remote attackers to use this community string to access the SNMPv1 service with read-write privileges.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
First Corporation's DVRs use a hard-coded password, which may allow a remote unauthenticated attacker to rewrite or obtain the configuration information of the affected device. Note that updates are provided only for Late model of CFR-4EABC, CFR-4EAB, CFR-8EAB, CFR-16EAB, MD-404AB, and MD-808AB. As for the other products, apply the workaround.
Multisuns EasyLog web+ has a vulnerability of using hard-coded credentials. An remote attacker can exploit this vulnerability to access the system to perform arbitrary system operations or disrupt service.
Because of hard-coded SSH keys for the root user in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series, Kami7B, an attacker may remotely log in through SSH.
Use of Hard-coded Credentials in EntoneWebEngine in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series and Kami7B allows remote attackers to retrieve and modify the device settings.
Natus NeuroWorks and SleepWorks before 8.4 GMA3 utilize a default password of xltek for the Microsoft SQL Server service sa account, allowing a threat actor to perform remote code execution, data exfiltration, or other nefarious actions such as tampering with data or destroying/disrupting MSSQL services.
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. We have confirmed this flaw in MiR100 and MiR200 but it might also apply to MiR250, MiR500 and MiR1000.
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.
The vulnerability allows a remote attacker to authenticate to the SSH service with root privileges through a hidden hard-coded account.
Novel-Plus v3.6.2 was discovered to contain a hard-coded JWT key located in the project config file. This vulnerability allows attackers to create a custom user session.
Multiple MachineSense devices have credentials unable to be changed by the user or administrator.
Baicells Nova436Q and Neutrino 430 devices with firmware through QRTB 2.7.8 have hardcoded credentials that are easily discovered, and can be used by remote attackers to authenticate via ssh. (The credentials are stored in the firmware, encrypted by the crypt function.)
The database account and password are hardcoded, allowing login with the account to manipulate the database in MagicInfo9 Server.This issue affects MagicINFO 9 Server: less than 21.1090.1.