Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-26128

Summary
Assigner-snyk
Assigner Org ID-bae035ff-b466-4ff4-94d0-fc9efd9e1730
Published At-27 May, 2023 | 05:00
Updated At-13 Jan, 2025 | 21:22
Rejected At-
Credits

All versions of the package keep-module-latest are vulnerable to Command Injection due to missing input sanitization or other checks and sandboxes being employed to the installModule function. **Note:** To execute the code snippet and potentially exploit the vulnerability, the attacker needs to have the ability to run Node.js code within the target environment. This typically requires some level of access to the system or application hosting the Node.js environment.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:snyk
Assigner Org ID:bae035ff-b466-4ff4-94d0-fc9efd9e1730
Published At:27 May, 2023 | 05:00
Updated At:13 Jan, 2025 | 21:22
Rejected At:
▼CVE Numbering Authority (CNA)

All versions of the package keep-module-latest are vulnerable to Command Injection due to missing input sanitization or other checks and sandboxes being employed to the installModule function. **Note:** To execute the code snippet and potentially exploit the vulnerability, the attacker needs to have the ability to run Node.js code within the target environment. This typically requires some level of access to the system or application hosting the Node.js environment.

Affected Products
Vendor
n/a
Product
keep-module-latest
Versions
Affected
  • From 0 before * (semver)
Problem Types
TypeCWE IDDescription
N/AN/ACommand Injection
Type: N/A
CWE ID: N/A
Description: Command Injection
Metrics
VersionBase scoreBase severityVector
3.18.4HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P
Version: 3.1
Base score: 8.4
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Johns Hopkins
Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://security.snyk.io/vuln/SNYK-JS-KEEPMODULELATEST-3157165
N/A
https://github.com/liujunyang/keep-module-latest/blob/master/index.js%23L50
N/A
Hyperlink: https://security.snyk.io/vuln/SNYK-JS-KEEPMODULELATEST-3157165
Resource: N/A
Hyperlink: https://github.com/liujunyang/keep-module-latest/blob/master/index.js%23L50
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://security.snyk.io/vuln/SNYK-JS-KEEPMODULELATEST-3157165
x_transferred
https://github.com/liujunyang/keep-module-latest/blob/master/index.js%23L50
x_transferred
Hyperlink: https://security.snyk.io/vuln/SNYK-JS-KEEPMODULELATEST-3157165
Resource:
x_transferred
Hyperlink: https://github.com/liujunyang/keep-module-latest/blob/master/index.js%23L50
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:report@snyk.io
Published At:27 May, 2023 | 05:15
Updated At:13 Jan, 2025 | 22:15

All versions of the package keep-module-latest are vulnerable to Command Injection due to missing input sanitization or other checks and sandboxes being employed to the installModule function. **Note:** To execute the code snippet and potentially exploit the vulnerability, the attacker needs to have the ability to run Node.js code within the target environment. This typically requires some level of access to the system or application hosting the Node.js environment.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.18.4HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.4
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

keep-module-latest_project
keep-module-latest_project
>>keep-module-latest>>*
cpe:2.3:a:keep-module-latest_project:keep-module-latest:*:*:*:*:*:node.js:*:*
Weaknesses
CWE IDTypeSource
CWE-78Secondaryreport@snyk.io
CWE-77Primarynvd@nist.gov
CWE-77Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-78
Type: Secondary
Source: report@snyk.io
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-77
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/liujunyang/keep-module-latest/blob/master/index.js%23L50report@snyk.io
Broken Link
https://security.snyk.io/vuln/SNYK-JS-KEEPMODULELATEST-3157165report@snyk.io
Exploit
Third Party Advisory
https://github.com/liujunyang/keep-module-latest/blob/master/index.js%23L50af854a3a-2127-422b-91ae-364da2661108
Broken Link
https://security.snyk.io/vuln/SNYK-JS-KEEPMODULELATEST-3157165af854a3a-2127-422b-91ae-364da2661108
Exploit
Third Party Advisory
Hyperlink: https://github.com/liujunyang/keep-module-latest/blob/master/index.js%23L50
Source: report@snyk.io
Resource:
Broken Link
Hyperlink: https://security.snyk.io/vuln/SNYK-JS-KEEPMODULELATEST-3157165
Source: report@snyk.io
Resource:
Exploit
Third Party Advisory
Hyperlink: https://github.com/liujunyang/keep-module-latest/blob/master/index.js%23L50
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Broken Link
Hyperlink: https://security.snyk.io/vuln/SNYK-JS-KEEPMODULELATEST-3157165
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

324Records found

CVE-2019-1893
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.8||HIGH
EPSS-0.14% / 34.20%
||
7 Day CHG~0.00%
Published-06 Jul, 2019 | 01:20
Updated-20 Nov, 2024 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Enterprise NFV Infrastructure Software Command Injection Vulnerability

A vulnerability in Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system (OS) of an affected device as root. The vulnerability is due to insufficient input validation of a configuration file that is accessible to a local shell user. An attacker could exploit this vulnerability by including malicious input during the execution of this file. A successful exploit could allow the attacker to execute arbitrary commands on the underlying OS as root.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-enterprise_nfv_infrastructure_softwareCisco Enterprise NFV Infrastructure Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-1883
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7||HIGH
EPSS-0.14% / 35.26%
||
7 Day CHG~0.00%
Published-21 Aug, 2019 | 18:20
Updated-20 Nov, 2024 | 17:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Integrated Management Controller CLI Command Injection Vulnerability

A vulnerability in the command-line interface of Cisco Integrated Management Controller (IMC) could allow an authenticated, local attacker with read-only credentials to inject arbitrary commands that could allow them to obtain root privileges. The vulnerability is due to insufficient validation of user-supplied input on the command-line interface. An attacker could exploit this vulnerability by authenticating with read-only privileges via the CLI of an affected device and submitting crafted input to the affected commands. A successful exploit could allow an attacker to execute arbitrary commands on the device with root privileges.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ucs_c125_m5ucs_s3260integrated_management_controller_supervisorucs-e1120d-m3ucs-e160s-m3ucs_c4200ucs-e140s-m2encs_5100ucs-e160d-m2encs_5400unified_computing_systemucs-e180d-m3ucs-e168d-m2Cisco Unified Computing System E-Series Software (UCSE)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-23383
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 5.82%
||
7 Day CHG-0.03%
Published-28 Mar, 2025 | 02:01
Updated-08 Jul, 2025 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-1726
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 16.76%
||
7 Day CHG~0.00%
Published-15 May, 2019 | 16:40
Updated-21 Nov, 2024 | 19:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco NX-OS Software CLI Bypass to Internal Service Vulnerability

A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to access internal services that should be restricted on an affected device, such as the NX-API. The vulnerability is due to insufficient validation of arguments passed to a certain CLI command. An attacker could exploit this vulnerability by including malicious input as the argument to the affected command. A successful exploit could allow the attacker to bypass intended restrictions and access internal services of the device. An attacker would need valid device credentials to exploit this vulnerability.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-nexus_3500nexus_3100vmds_9500mds_9000nexus_9200nexus_5600nx-osnexus_3200mds_9700ucs_6296upnexus_6000ucs_6248upnexus_5500nexus_3400nexus_3100nexus_9000mds_9100nexus_9500nexus_3548-xnexus_3100-znexus_7000nexus_3524-xlnexus_9300nexus_3548-xlnexus_3000nexus_3600mds_9200nexus_7700nexus_3524-xCisco NX-OS Software
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-1735
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-4.4||MEDIUM
EPSS-0.09% / 26.58%
||
7 Day CHG~0.00%
Published-15 May, 2019 | 18:45
Updated-21 Nov, 2024 | 19:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco NX-OS Software Command Injection Vulnerability (CVE-2019-1735)

A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands with elevated privileges on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid user credentials to exploit this vulnerability.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-nexus_93180lc-exucs_6332-16upnexus_9332pqnexus_3172tqnexus_93108tc-exnx-osnexus_3636c-rnexus_9508nexus_93120txnexus_6000nexus_93128txnexus_9336pq_aci_spinenexus_1000venexus_3548-xlnexus_31128pqnexus_3132q-vnexus_9332cnexus_9364cnexus_3164qnexus_92348gc-xnexus_3172tq-32tnexus_9336c-fx2mds_9200nexus_3524-xnexus_3132c-znexus_31108tc-vnexus_9348gc-fxpnexus_3172mds_9000nexus_9272qnexus_3464cmds_9700nexus_93216tc-fx2nexus_36180yc-rnexus_5500nexus_93180yc-fxnexus_3264qnexus_3432d-snexus_34180ycnexus_9000vnexus_31108pc-vnexus_3524nexus_3548mds_9500nexus_3132qnexus_3016nexus_9372pxnexus_92304qcnexus_92160yc-xucs_6248upmds_9100nexus_9504nexus_3048nexus_9372tx-enexus_93108tc-fxnexus_93360yc-fx2nexus_3524-xlucs_6324nexus_9396txnexus_7000nexus_92300ycnexus_3064ucs_6332nexus_3232cnexus_5600nexus_9396pxucs_6296upnexus_1000vnexus_3264c-enexus_93240yc-fx2nexus_9372txnexus_3548-xnexus_3132q-xlnexus_3064-tnexus_3172tq-xlnexus_93180yc-exnexus_3408-snexus_9372px-enexus_9236cnexus_9516nexus_3172pq-xlnexus_7700Cisco NX-OS Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
CVE-2019-1745
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-0.10% / 27.92%
||
7 Day CHG~0.00%
Published-27 Mar, 2019 | 23:40
Updated-20 Nov, 2024 | 17:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOS XE Software Command Injection Vulnerability

A vulnerability in Cisco IOS XE Software could allow an authenticated, local attacker to inject arbitrary commands that are executed with elevated privileges. The vulnerability is due to insufficient input validation of commands supplied by the user. An attacker could exploit this vulnerability by authenticating to a device and submitting crafted input to the affected commands. An exploit could allow the attacker to gain root privileges on the affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ios_xeCisco IOS XE Software
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-17650
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-7.8||HIGH
EPSS-0.12% / 31.45%
||
7 Day CHG~0.00%
Published-21 Nov, 2019 | 15:03
Updated-25 Oct, 2024 | 14:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Neutralization of Special Elements used in a Command vulnerability in one of FortiClient for Mac OS root processes, may allow a local user of the system on which FortiClient is running to execute unauthorized code as root by bypassing a security check.

Action-Not Available
Vendor-Fortinet, Inc.
Product-forticlientFortiClient for Mac OS
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-52624
Matching Score-4
Assigner-kernel.org
ShareView Details
Matching Score-4
Assigner-kernel.org
CVSS Score-7.8||HIGH
EPSS-0.01% / 1.75%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:49
Updated-11 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
drm/amd/display: Wake DMCUB before executing GPINT commands

In the Linux kernel, the following vulnerability has been resolved: drm/amd/display: Wake DMCUB before executing GPINT commands [Why] DMCUB can be in idle when we attempt to interface with the HW through the GPINT mailbox resulting in a system hang. [How] Add dc_wake_and_execute_gpint() to wrap the wake, execute, sleep sequence. If the GPINT executes successfully then DMCUB will be put back into sleep after the optional response is returned. It functions similar to the inbox command interface.

Action-Not Available
Vendor-Linux Kernel Organization, Inc
Product-linux_kernelLinux
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-40396
Matching Score-4
Assigner-Apple Inc.
ShareView Details
Matching Score-4
Assigner-Apple Inc.
CVSS Score-7.8||HIGH
EPSS-0.19% / 41.43%
||
7 Day CHG+0.13%
Published-29 Jul, 2024 | 20:21
Updated-19 Mar, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The issue was addressed with improved memory handling. This issue is fixed in iOS 17 and iPadOS 17, macOS Sonoma 14, watchOS 10, tvOS 17. An app may be able to execute arbitrary code with kernel privileges.

Action-Not Available
Vendor-Apple Inc.
Product-watchosiphone_osmacostvosipadosmacOSwatchOSiOS and iPadOStvOSiosipad_os
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-50445
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-2.59% / 85.00%
||
7 Day CHG~0.00%
Published-28 Dec, 2023 | 00:00
Updated-02 Aug, 2024 | 22:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Shell Injection vulnerability GL.iNet A1300 v4.4.6, AX1800 v4.4.6, AXT1800 v4.4.6, MT3000 v4.4.6, MT2500 v4.4.6, MT6000 v4.5.0, MT1300 v4.3.7, MT300N-V2 v4.3.7, AR750S v4.3.7, AR750 v4.3.7, AR300M v4.3.7, and B1300 v4.3.7., allows local attackers to execute arbitrary code via the get_system_log and get_crash_log functions of the logread module, as well as the upgrade_online function of the upgrade module.

Action-Not Available
Vendor-gl-inetn/agl.inet
Product-gl-b1300_firmwaregl-mt3000_firmwaregl-mt2500gl-ar300m_firmwaregl-mt6000_firmwaregl-mt1300gl-ax1800gl-mt1300_firmwaregl-ar300mgl-ar750sgl-mt3000gl-ar750_firmwaregl-mt2500_firmwaregl-b1300gl-axt1800gl-a1300_firmwaregl-ax1800_firmwaregl-mt6000gl-mt300n-v2gl-a1300gl-mt300n-v2_firmwaregl-ar750s_firmwaregl-ar750gl-axt1800_firmwaren/aAR300MA1300MT1300MT6000AXT1800MT2500AR750MT3000MT300N_V2B1300AR750SAX1800
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-17148
Matching Score-4
Assigner-Zero Day Initiative
ShareView Details
Matching Score-4
Assigner-Zero Day Initiative
CVSS Score-7.8||HIGH
EPSS-0.13% / 32.73%
||
7 Day CHG~0.00%
Published-07 Jan, 2020 | 23:05
Updated-05 Aug, 2024 | 01:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows local attackers to escalate privileges on affected installations of Parallels Desktop Parallels Desktop version 14.1.3 (45485). An attacker must first obtain the ability to execute low-privileged code on the target guest system in order to exploit this vulnerability. The specific flaw exists within the Parallels Service. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of root. Was ZDI-CAN-8685.

Action-Not Available
Vendor-Parallels International Gmbh
Product-parallels_desktopDesktop
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-1646
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.8||HIGH
EPSS-0.10% / 27.92%
||
7 Day CHG~0.00%
Published-24 Jan, 2019 | 15:00
Updated-20 Nov, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Privilege Escalation Vulnerability in Cisco SD-WAN Solution

A vulnerability in the local CLI of the Cisco SD-WAN Solution could allow an authenticated, local attacker to escalate privileges and modify device configuration files. The vulnerability exists because user input is not properly sanitized for certain commands at the CLI. An attacker could exploit this vulnerability by sending crafted commands to the CLI of an affected device. A successful exploit could allow the attacker to establish an interactive session with elevated privileges. The attacker could then use the elevated privileges to further compromise the device or obtain additional configuration data from the device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-vedge_2000sd-wanvedge_100_firmwarevbond_orchestratorvedge_5000_firmwarevedge_1000_firmwarevedge_5000vsmart_controllervedge_100vmanage_network_managementvedge_2000_firmwarevedge_1000Cisco SD-WAN Solution
CWE ID-CWE-264
Not Available
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-50274
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.8||HIGH
EPSS-0.28% / 51.08%
||
7 Day CHG~0.00%
Published-23 Jan, 2024 | 17:02
Updated-30 May, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

HPE OneView may allow command injection with local privilege escalation.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)HP Inc.
Product-oneviewHPE OneView
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-1591
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.8||HIGH
EPSS-0.24% / 46.66%
||
7 Day CHG~0.00%
Published-06 Mar, 2019 | 22:00
Updated-20 Nov, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Nexus 9000 Series Fabric Switches Application Centric Infrastructure Mode Shell Escape Vulnerability

A vulnerability in a specific CLI command implementation of Cisco Nexus 9000 Series ACI Mode Switch Software could allow an authenticated, local attacker to escape a restricted shell on an affected device. The vulnerability is due to insufficient sanitization of user-supplied input when issuing a specific CLI command with parameters on an affected device. An attacker could exploit this vulnerability by authenticating to the device CLI and issuing certain commands. A successful exploit could allow the attacker to escape the restricted shell and execute arbitrary commands with root-level privileges on the affected device. This vulnerability only affects Cisco Nexus 9000 Series ACI Mode Switches that are running a release prior to 14.0(3d).

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-nexus_9000nx-osCisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode
CWE ID-CWE-264
Not Available
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-14719
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.27%
||
7 Day CHG~0.00%
Published-23 Oct, 2020 | 04:35
Updated-05 Aug, 2024 | 00:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Verifone MX900 series Pinpad Payment Terminals with OS 30251000 allow multiple arbitrary command injections, as demonstrated by the file manager.

Action-Not Available
Vendor-verifonen/a
Product-mx900mx900_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-37937
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-7.6||HIGH
EPSS-0.11% / 30.51%
||
7 Day CHG~0.00%
Published-14 Jan, 2025 | 14:09
Updated-31 Jan, 2025 | 17:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper neutralization of special elements used in an os command ('os command injection') in Fortinet FortiSwitch version 7.4.0 and 7.2.0 through 7.2.5 and 7.0.0 through 7.0.7 and 6.4.0 through 6.4.13 and 6.2.0 through 6.2.7 and 6.0.0 through 6.0.7 allows attacker to execute unauthorized code or commands via the FortiSwitch CLI.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortiswitchFortiSwitch
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-0396
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.5||HIGH
EPSS-0.29% / 52.05%
||
7 Day CHG~0.00%
Published-12 Jan, 2025 | 12:00
Updated-13 Jan, 2025 | 15:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
exelban stats XPC Service shouldAcceptNewConnection command injection

A vulnerability, which was classified as critical, has been found in exelban stats up to 2.11.21. This issue affects the function shouldAcceptNewConnection of the component XPC Service. The manipulation leads to command injection. It is possible to launch the attack on the local host. Upgrading to version 2.11.22 is able to address this issue. It is recommended to upgrade the affected component.

Action-Not Available
Vendor-exelban
Product-stats
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-15351
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.13% / 33.56%
||
7 Day CHG~0.00%
Published-14 Nov, 2019 | 16:24
Updated-05 Aug, 2024 | 00:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Tecno Camon Android device with a build fingerprint of TECNO/H622/TECNO-ID5b:8.1.0/O11019/G-180829V31:user/release-keys contains a pre-installed platform app with a package name of com.lovelyfont.defcontainer (versionCode=7, versionName=7.0.11). This app contains an exported service named com.lovelyfont.manager.FontCoverService that allows any app co-located on the device to supply arbitrary commands via shell script to be executed as the system user that are triggered by writing an attacker-selected message to the logcat log. This app cannot be disabled by the user and the attack can be performed by a zero-permission app. Executing commands as the system user can allow a third-party app to video record the user's screen, factory reset the device, obtain the user's notifications, read the logcat logs, inject events in the Graphical User Interface (GUI), and obtains the user's text messages, and more. Executing commands as the system user can allow a third-party app to factory reset the device, obtain the user's notifications, read the logcat logs, inject events in the GUI, change the default Input Method Editor (IME) (e.g., keyboard) with one contained within the attacking app that contains keylogging functionality, and obtains the user's text messages, and more.

Action-Not Available
Vendor-n/aTECNO MOBILE LIMITED
Product-tecno\/h622\/tecno-id5b\n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-12699
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-0.17% / 39.19%
||
7 Day CHG~0.00%
Published-02 Oct, 2019 | 19:06
Updated-20 Nov, 2024 | 17:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco FXOS Software and Firepower Threat Defense Software Command Injection Vulnerabilities

Multiple vulnerabilities in the CLI of Cisco FXOS Software and Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to execute commands on the underlying operating system (OS) with root privileges. These vulnerabilities are due to insufficient input validation. An attacker could exploit these vulnerabilities by including crafted arguments to specific CLI commands. A successful exploit could allow the attacker to execute commands on the underlying OS with root privileges.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-firepower_9300firepower_4100firepower_2100firepower_threat_defensefirepower_9300_firmwarefirepower_extensible_operating_systemfirepower_1000Cisco Firepower Extensible Operating System (FXOS)
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-12717
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.7||MEDIUM
EPSS-0.12% / 32.46%
||
7 Day CHG~0.00%
Published-25 Sep, 2019 | 20:16
Updated-20 Nov, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco NX-OS Software Virtualization Manager Command Injection Vulnerability

A vulnerability in a CLI command related to the virtualization manager (VMAN) in Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying Linux operating system with root privileges. The vulnerability is due to insufficient validation of arguments passed to a specific VMAN CLI command on an affected device. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying Linux operating system with root privileges, which may lead to complete system compromise. An attacker would need valid administrator credentials to exploit this vulnerability.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-nexus_93180lc-exnexus_56128pnexus_9332pqnexus_3172tqnexus_93108tc-exnx-osnexus_3636c-rnexus_9508nexus_93120txnexus_93128txnexus_9336pq_aci_spinenexus_6004nexus_3548-xlnexus_31128pqnexus_3132q-vnexus_9332cnexus_7000_9-slotnexus_9364cnexus_92348gc-xnexus_3172tq-32tnexus_9336c-fx2nexus_3164qnexus_3524-xnexus_3132c-znexus_31108tc-vnexus_5548pnexus_9348gc-fxpnexus_5648qnexus_3172nexus_9272qnexus_3464cnexus_93216tc-fx2nexus_36180yc-rnexus_5672upnexus_93180yc-fxnexus_3264qnexus_3432d-snexus_34180ycnexus_9000vnexus_31108pc-vnexus_7700_18-slotnexus_5596upnexus_3524nexus_3548nexus_7000_4-slotnexus_7700_6-slotnexus_3132qnexus_3016nexus_9372pxnexus_5696qnexus_92304qcnexus_92160yc-xnexus_7700_10-slotnexus_9500nexus_3048nexus_9372tx-enexus_9504nexus_6001nexus_93108tc-fxnexus_93360yc-fx2nexus_3524-xlnexus_9396txnexus_7000_10-slotnexus_7000nexus_92300ycnexus_3064nexus_3232cnexus_5548upnexus_9396pxnexus_5596tnexus_3264c-enexus_7700_2-slotnexus_93240yc-fx2nexus_9372txnexus_5624qnexus_3548-xnexus_6004xnexus_3132q-xlnexus_3064-tnexus_3172tq-xlnexus_93180yc-exnexus_3408-snexus_9372px-enexus_7000_18-slotnexus_9236cnexus_9516nexus_3172pq-xlnexus_7700Cisco NX-OS Software 5.0(3)A1(1)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-34642
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.88%
||
7 Day CHG~0.00%
Published-19 Jun, 2023 | 00:00
Updated-12 Dec, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

KioWare for Windows through v8.33 was discovered to contain an incomplete blacklist filter for blocked dialog boxes on Windows 10. This issue can allow attackers to open a file dialog box via the function showDirectoryPicker() which can then be used to open an unprivileged command prompt.

Action-Not Available
Vendor-kiowaren/a
Product-kiowaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-33298
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.23% / 45.64%
||
7 Day CHG~0.00%
Published-30 Jun, 2023 | 00:00
Updated-27 Nov, 2024 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

com.perimeter81.osx.HelperTool in Perimeter81 10.0.0.19 on macOS allows Local Privilege Escalation (to root) via shell metacharacters in usingCAPath.

Action-Not Available
Vendor-perimeter81n/a
Product-xpc_helpertooln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-3313
Matching Score-4
Assigner-Trellix
ShareView Details
Matching Score-4
Assigner-Trellix
CVSS Score-7.8||HIGH
EPSS-0.18% / 40.11%
||
7 Day CHG~0.00%
Published-03 Jul, 2023 | 07:53
Updated-22 Nov, 2024 | 16:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS common injection vulnerability exists in the ESM certificate API, whereby incorrectly neutralized special elements may have allowed an unauthorized user to execute system command injection for the purpose of privilege escalation or to execute arbitrary commands.

Action-Not Available
Vendor-Musarubra US LLC (Trellix)
Product-enterprise_security_managerEnterprise Security Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-33806
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.08% / 24.81%
||
7 Day CHG~0.00%
Published-15 Apr, 2024 | 00:00
Updated-20 Jun, 2025 | 19:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Insecure default configurations in Hikvision Interactive Tablet DS-D5B86RB/B V2.3.0 build220119, allows attackers to execute arbitrary commands.

Action-Not Available
Vendor-n/aHIKVISION
Product-ds-d5b86rb\/b_firmwareds-d5b86rb\/bn/ads-d5b86rb\/b_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-1606
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-5.3||MEDIUM
EPSS-0.16% / 37.47%
||
7 Day CHG~0.00%
Published-08 Mar, 2019 | 20:00
Updated-21 Nov, 2024 | 19:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1606)

A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid user credentials to exploit this vulnerability. Nexus 3000, 3500, and Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I7(4).

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-nexus_9000nexus_3000nx-osnexus_3500Nexus 3500 Platform SwitchesNexus 3000 Series SwitchesNexus 9000 Series Switches in Standalone NX-OS Mode
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
CVE-2019-1000018
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.24% / 46.86%
||
7 Day CHG~0.00%
Published-04 Feb, 2019 | 21:00
Updated-19 Mar, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

rssh version 2.3.4 contains a CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in allowscp permission that can result in Local command execution. This attack appear to be exploitable via An authorized SSH user with the allowscp permission.

Action-Not Available
Vendor-pizzashackn/aFedora ProjectDebian GNU/LinuxCanonical Ltd.
Product-rsshdebian_linuxfedoraubuntu_linuxn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-16011
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.8||HIGH
EPSS-0.09% / 27.28%
||
7 Day CHG~0.00%
Published-29 Apr, 2020 | 20:40
Updated-15 Nov, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOS XE SD-WAN Software Command Injection Vulnerability

A vulnerability in the CLI of Cisco IOS XE SD-WAN Software could allow an authenticated, local attacker to inject arbitrary commands that are executed with root privileges. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by authenticating to the device and submitting crafted input to the CLI utility. The attacker must be authenticated to access the CLI utility. A successful exploit could allow the attacker to execute commands with root privileges.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-asr_10134431_integrated_services_routerasr_1002-hx1100_integrated_services_routerios_xe4221_integrated_services_router4331_integrated_services_routerasr_10064461_integrated_services_routerasr_1001-xasr_1001-hxasr_1004asr_1002-xcsr1000vasr_1009-xasr_1006-xCisco IOS XE SD-WAN Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2024-39567
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.31% / 53.86%
||
7 Day CHG+0.07%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_clientSINEMA Remote Connect Clientsinema_remote_connect_client
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-15343
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.13% / 33.56%
||
7 Day CHG~0.00%
Published-14 Nov, 2019 | 16:24
Updated-05 Aug, 2024 | 00:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Tecno Camon iClick Android device with a build fingerprint of TECNO/H633/TECNO-IN6:8.1.0/O11019/A-180409V96:user/release-keys contains a pre-installed platform app with a package name of com.lovelyfont.defcontainer (versionCode=7, versionName=7.0.8). This app contains an exported service named com.lovelyfont.manager.FontCoverService that allows any app co-located on the device to supply arbitrary commands via shell script to be executed as the system user that are triggered by writing an attacker-selected message to the logcat log. This app cannot be disabled by the user and the attack can be performed by a zero-permission app. Executing commands as the system user can allow a third-party app to video record the user's screen, factory reset the device, obtain the user's notifications, read the logcat logs, inject events in the Graphical User Interface (GUI), and obtains the user's text messages, and more. Executing commands as the system user can allow a third-party app to factory reset the device, obtain the user's notifications, read the logcat logs, inject events in the GUI, change the default Input Method Editor (IME) (e.g., keyboard) with one contained within the attacking app that contains keylogging functionality, and obtains the user's text messages, and more.

Action-Not Available
Vendor-n/aTECNO MOBILE LIMITED
Product-camon_iclickcamon_iclick_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-31425
Matching Score-4
Assigner-Brocade Communications Systems, LLC
ShareView Details
Matching Score-4
Assigner-Brocade Communications Systems, LLC
CVSS Score-7.8||HIGH
EPSS-0.11% / 30.17%
||
7 Day CHG~0.00%
Published-01 Aug, 2023 | 20:34
Updated-13 Feb, 2025 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Privilege escalation via the fosexec command

A vulnerability in the fosexec command of Brocade Fabric OS after Brocade Fabric OS v9.1.0 and, before Brocade Fabric OS v9.1.1 could allow a local authenticated user to perform privilege escalation to root by breaking the rbash shell. Starting with Fabric OS v9.1.0, “root” account access is disabled.

Action-Not Available
Vendor-Broadcom Inc.Brocade Communications Systems, Inc. (Broadcom Inc.)
Product-fabric_operating_systemFabric OS
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7883
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.5||HIGH
EPSS-0.10% / 27.50%
||
7 Day CHG+0.02%
Published-20 Jul, 2025 | 10:44
Updated-22 Jul, 2025 | 13:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Eluktronics Control Center Powershell Script Command command injection

A vulnerability classified as critical has been found in Eluktronics Control Center 5.23.51.41. Affected is an unknown function of the file \AiStoneService\MyControlCenter\Command of the component Powershell Script Handler. The manipulation leads to command injection. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Eluktronics
Product-Control Center
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-15348
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.11% / 30.64%
||
7 Day CHG~0.00%
Published-14 Nov, 2019 | 16:24
Updated-05 Aug, 2024 | 00:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Tecno Camon Android device with a build fingerprint of TECNO/H612/TECNO-ID5a:8.1.0/O11019/F-180828V106:user/release-keys contains a pre-installed platform app with a package name of com.lovelyfont.defcontainer (versionCode=7, versionName=7.0.11). This app contains an exported service named com.lovelyfont.manager.FontCoverService that allows any app co-located on the device to supply arbitrary commands via shell script to be executed as the system user that are triggered by writing an attacker-selected message to the logcat log. This app cannot be disabled by the user and the attack can be performed by a zero-permission app. Executing commands as the system user can allow a third-party app to video record the user's screen, factory reset the device, obtain the user's notifications, read the logcat logs, inject events in the Graphical User Interface (GUI), and obtains the user's text messages, and more. Executing commands as the system user can allow a third-party app to factory reset the device, obtain the user's notifications, read the logcat logs, inject events in the GUI, change the default Input Method Editor (IME) (e.g., keyboard) with one contained within the attacking app that contains keylogging functionality, and obtains the user's text messages, and more.

Action-Not Available
Vendor-n/aTECNO MOBILE LIMITED
Product-tecno\/h612\/tecno-id5a\n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-28906
Matching Score-4
Assigner-Automotive Security Research Group (ASRG)
ShareView Details
Matching Score-4
Assigner-Automotive Security Research Group (ASRG)
CVSS Score-7.8||HIGH
EPSS-0.04% / 12.07%
||
7 Day CHG~0.00%
Published-28 Jun, 2025 | 15:36
Updated-30 Jun, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command injection in networking service

A command injection in the networking service of the MIB3 infotainment allows an attacker already presenting in the system to escalate privileges and obtain administrative access to the system. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources.

Action-Not Available
Vendor-Preh Car Connect GmbH (JOYNEXT GmbH)
Product-Volkswagen MIB3 infotainment system MIB3 OI MQB
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-28000
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-6.3||MEDIUM
EPSS-0.08% / 23.57%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:41
Updated-23 Oct, 2024 | 14:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper neutralization of special elements used in an OS command vulnerability [CWE-78] in FortiADC CLI 7.1.0, 7.0.0 through 7.0.3, 6.2.0 through 6.2.4, 6.1 all versions, 6.0 all versions may allow a local and authenticated attacker to execute unauthorized commands via specifically crafted arguments in diagnose system df CLI command.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortiadcFortiADC
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-28528
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-8.4||HIGH
EPSS-2.27% / 83.97%
||
7 Day CHG~0.00%
Published-28 Apr, 2023 | 02:06
Updated-13 Feb, 2025 | 16:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
IBM AIX command execution

IBM AIX 7.1, 7.2, 7.3, and VIOS 3.1 could allow a non-privileged local user to exploit a vulnerability in the invscout command to execute arbitrary commands. IBM X-Force ID: 251207.

Action-Not Available
Vendor-IBM Corporation
Product-aixviosAIX
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-27999
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-7.6||HIGH
EPSS-0.17% / 38.70%
||
7 Day CHG~0.00%
Published-03 May, 2023 | 21:26
Updated-23 Oct, 2024 | 14:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper neutralization of special elements used in an OS command vulnerability [CWE-78] in FortiADC 7.2.0, 7.1.0 through 7.1.1 may allow an authenticated attacker to execute unauthorized commands via specifically crafted arguments to existing commands.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortiadcFortiADC
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-14868
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-7.4||HIGH
EPSS-1.07% / 76.87%
||
7 Day CHG+0.07%
Published-02 Apr, 2020 | 16:48
Updated-05 Aug, 2024 | 00:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In ksh version 20120801, a flaw was found in the way it evaluates certain environment variables. An attacker could use this flaw to override or bypass environment restrictions to execute shell commands. Services and applications that allow remote unauthenticated attackers to provide one of those environment variables could allow them to exploit this issue remotely.

Action-Not Available
Vendor-ksh_projectKornShellDebian GNU/LinuxApple Inc.
Product-debian_linuxmac_os_xkshksh
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-36667
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-1.07% / 76.83%
||
7 Day CHG~0.00%
Published-11 Jul, 2022 | 15:06
Updated-04 Aug, 2024 | 01:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command injection vulnerability in Druva inSync 6.9.0 for MacOS, allows attackers to execute arbitrary commands via crafted payload to the local HTTP server due to un-sanitized call to the python os.system library.

Action-Not Available
Vendor-druvan/a
Product-insync_clientn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-26127
Matching Score-4
Assigner-Snyk
ShareView Details
Matching Score-4
Assigner-Snyk
CVSS Score-7.8||HIGH
EPSS-0.16% / 37.40%
||
7 Day CHG~0.00%
Published-27 May, 2023 | 05:00
Updated-13 Jan, 2025 | 22:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

All versions of the package n158 are vulnerable to Command Injection due to improper input sanitization in the 'module.exports' function. **Note:** To execute the code snippet and potentially exploit the vulnerability, the attacker needs to have the ability to run Node.js code within the target environment. This typically requires some level of access to the system or application hosting the Node.js environment.

Action-Not Available
Vendor-n158_projectn/a
Product-n158n158
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-25607
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-7.4||HIGH
EPSS-0.15% / 36.24%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 16:51
Updated-22 Oct, 2024 | 20:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper neutralization of special elements used in an OS Command ('OS Command Injection') vulnerability [CWE-78 ] in FortiManager 7.2.0 through 7.2.2, 7.0.0 through 7.0.7, 6.4.0 through 6.4.11, 6.2 all versions, 6.0 all versions, FortiAnalyzer 7.2.0 through 7.2.2, 7.0.0 through 7.0.7, 6.4.0 through 6.4.11, 6.2 all versions, 6.0 all versions and FortiADC  7.1.0, 7.0.0 through 7.0.3, 6.2 all versions, 6.1 all versions, 6.0 all versions management interface may allow an authenticated attacker with at least READ permissions on system settings to execute arbitrary commands on the underlying shell due to an unsafe usage of the wordexp function.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortianalyzerfortiadcfortimanagerFortiManagerFortiADCFortiAnalyzer
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-26294
Matching Score-4
Assigner-HP Inc.
ShareView Details
Matching Score-4
Assigner-HP Inc.
CVSS Score-7.8||HIGH
EPSS-0.66% / 70.11%
||
7 Day CHG~0.00%
Published-12 Jun, 2023 | 21:17
Updated-06 Jan, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Previous versions of HP Device Manager (prior to HPDM 5.0.10) could potentially allow command injection and/or elevation of privileges.

Action-Not Available
Vendor-HP Inc.
Product-hp_device_managerHP Device Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-25554
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.14% / 33.91%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:34
Updated-12 Feb, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-26129
Matching Score-4
Assigner-Snyk
ShareView Details
Matching Score-4
Assigner-Snyk
CVSS Score-8.4||HIGH
EPSS-0.32% / 54.62%
||
7 Day CHG~0.00%
Published-27 May, 2023 | 05:00
Updated-13 Jan, 2025 | 22:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

All versions of the package bwm-ng are vulnerable to Command Injection due to improper input sanitization in the 'check' function in the bwm-ng.js file. **Note:** To execute the code snippet and potentially exploit the vulnerability, the attacker needs to have the ability to run Node.js code within the target environment. This typically requires some level of access to the system or application hosting the Node.js environment.

Action-Not Available
Vendor-bwm-ng_projectn/a
Product-bwm-ngbwm-ng
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-24229
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-1.48% / 80.19%
||
7 Day CHG~0.00%
Published-15 Mar, 2023 | 00:00
Updated-02 Aug, 2024 | 11:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

DrayTek Vigor2960 v1.5.1.4 allows an authenticated attacker with network access to the web management interface to inject operating system commands via the mainfunction.cgi 'parameter' parameter. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-vigor2960_firmwarevigor2960n/avigor2960_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-54564
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.03% / 8.37%
||
7 Day CHG~0.00%
Published-01 Aug, 2025 | 00:00
Updated-04 Aug, 2025 | 15:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

uploadsm in ChargePoint Home Flex 5.5.4.13 does not validate a user-controlled string for bz2 decompression, which allows command execution as the nobody user.

Action-Not Available
Vendor-n/a
Product-n/a
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-24032
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.07% / 22.59%
||
7 Day CHG~0.00%
Published-15 Jun, 2023 | 00:00
Updated-18 Dec, 2024 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Zimbra Collaboration Suite through 9.0 and 8.8.15, an attacker (who has initial user access to a Zimbra server instance) can execute commands as root by passing one of JVM arguments, leading to local privilege escalation (LPE).

Action-Not Available
Vendor-n/aZimbra
Product-collaborationn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-24135
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-22 Jan, 2024 | 00:00
Updated-04 Sep, 2024 | 20:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Jensen of Scandinavia Eagle 1200AC V15.03.06.33_en was discovered to contain a command injection vulnerability in the function formWriteFacMac. This vulnerability allows attackers to execute arbitrary commands via manipulation of the mac parameter.

Action-Not Available
Vendor-jensenofscandinavian/ajensenofscandinavia
Product-eagle_1200aceagle_1200ac_firmwaren/aeagle_1200ac_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-3969
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.2||HIGH
EPSS-0.12% / 31.99%
||
7 Day CHG~0.00%
Published-21 Mar, 2019 | 15:26
Updated-05 Aug, 2024 | 04:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable vulnerability exists in the verified boot protection of the CUJO Smart Firewall. It is possible to add arbitrary shell commands into the dhcpd.conf file, that persist across reboots and firmware updates, and thus allow for executing unverified commands. To trigger this vulnerability, a local attacker needs to be able to write into /config/dhcpd.conf.

Action-Not Available
Vendor-getcujon/a
Product-smart_firewallCUJO
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-54377
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.8||HIGH
EPSS-0.09% / 25.99%
||
7 Day CHG+0.02%
Published-23 Jul, 2025 | 20:36
Updated-23 Jul, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Roo Code Lacks Line Break Validation in its Command Execution Tool

Roo Code is an AI-powered autonomous coding agent that lives in users' editors. In versions 3.23.18 and below, RooCode does not validate line breaks (\n) in its command input, allowing potential bypass of the allow-list mechanism. The project appears to lack parsing or validation logic to prevent multi-line command injection. When commands are evaluated for execution, only the first line or token may be considered, enabling attackers to smuggle additional commands in subsequent lines. This is fixed in version 3.23.19.

Action-Not Available
Vendor-RooCodeInc
Product-Roo-Code
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-3836
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7||HIGH
EPSS-0.09% / 26.70%
||
7 Day CHG~0.00%
Published-24 Apr, 2018 | 19:00
Updated-16 Sep, 2024 | 16:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the gplotMakeOutput function of Leptonica 1.74.4. A specially crafted gplot rootname argument can cause a command injection resulting in arbitrary code execution. An attacker can provide a malicious path as input to an application that passes attacker data to this function to trigger this vulnerability.

Action-Not Available
Vendor-leptonicaDan BloombergDebian GNU/Linux
Product-leptonicadebian_linuxLeptonica
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • Next
Details not found