An issue was discovered in Chadha PHPKB 9.0 Enterprise Edition. installer/test-connection.php (part of the installation process) allows a remote unauthenticated attacker to disclose local files on hosts running PHP before 7.2.16, or on hosts where the MySQL ALLOW LOCAL DATA INFILE option is enabled.
An issue was discovered in CIPPlanner CIPAce 6.80 Build 2016031401. GetDistributedPOP3 allows attackers to obtain the username and password of the SMTP user.
Zoho ManageEngine OpManager before 125120 allows an unauthenticated user to retrieve an API key via a servlet call.
TerraMaster NAS 4.2.29 and earlier allows remote attackers to discover the administrative password by sending "User-Agent: TNAS" to module/api.php?mobile/webNasIPS and then reading the PWD field in the response.
Xiaomi router R3600 ROM before 1.0.50 is affected by a sensitive information leakage caused by an insecure interface get_config_result without authentication
An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
TeamPass 2.1.27.36 allows an unauthenticated attacker to retrieve files from the TeamPass web root. This may include backups or LDAP debug files.
The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.
An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Motorola FX9500 devices allow remote attackers to read database files.
An issue was discovered where a page is exposed that has the current administrator password in cleartext in the source code of the page. No authentication is required in order to reach the page (a certain live_?.shtml page with the variable syspasswd). Affected Devices: Wavlink WN530HG4, Wavlink WN531G3, and Wavlink WN572HG3
Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files.
An issue was discovered on Samsung mobile devices with Q(10.0) software. The DeX Lockscreen allows attackers to access the quick panel and notifications. The Samsung ID is SVE-2019-16532 (March 2020).
In affected versions of WordPress, some private posts, which were previously public, can result in unauthenticated disclosure under a specific set of conditions. This has been patched in version 5.4.1, along with all the previously affected versions via a minor release (5.3.3, 5.2.6, 5.1.5, 5.0.9, 4.9.14, 4.8.13, 4.7.17, 4.6.18, 4.5.21, 4.4.22, 4.3.23, 4.2.27, 4.1.30, 4.0.30, 3.9.31, 3.8.33, 3.7.33).
An issue was discovered in Wavlink WN530HG4, Wavlink WN531G3, Wavlink WN533A8, and Wavlink WN551K1 affecting /cgi-bin/ExportAllSettings.sh where a crafted POST request returns the current configuration of the device, including the administrator password. No authentication is required. The attacker must perform a decryption step, but all decryption information is readily available.
A web application for configuring the controller is accessible at a specific path. It contains an endpoint that allows an unauthenticated remote attacker to read files from the system’s file structure.
Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol leaks information regarding the receiving serverinformation, license information and managing licenses, among others.Through this flaw, attackers can retreive information about a KUKA simulation system, particularly, the version ofthe licensing server, which is connected to the simulator, and which will allow them to launch local simulationswith similar characteristics, further understanding the dynamics of motion virtualization and opening doors toother attacks (see RVDP#711 and RVDP#712 for subsequent vulnerabilities that compromise integrity andavailability).Beyond compromising simulations, Visual Components provides capabilities to interface with industrial machinery.Particularly, their PLC Connectivity feature 'makes it easy' to connect simulations with control systems usingeither the industry standard OPC UA or other supported vendor specific interfaces. This fills the gap of jumpingfrom simulation to real and enables attackers to pivot from the Visual Components simulator to robots or otherIndustrial Control System (ICS) devices, such as PLCs.
An issue was discovered on Samsung mobile devices with O(8.x) software. Access to Gallery in the Secure Folder can occur without authentication. The Samsung ID is SVE-2018-13057 (December 2018).
D-Link routers with the mydlink feature have some web interfaces without authentication requirements. An attacker can remotely obtain users' DNS query logs and login logs. Vulnerable targets include but are not limited to the latest firmware versions of DIR-817LW (A1-1.04), DIR-816L (B1-2.06), DIR-816 (B1-2.06?), DIR-850L (A1-1.09), and DIR-868L (A1-1.10).
In WhatsUp Gold versions released before 2023.1, an API endpoint was found to be missing an authentication mechanism. It is possible for an unauthenticated attacker to enumerate ancillary credential information stored within WhatsUp Gold.
All versions up to BD_R218V2.4 of ZTE MF920 product are impacted by information leak vulnerability. Due to some interfaces can obtain the WebUI login password without login, an attacker can exploit the vulnerability to obtain sensitive information about the affected components.
An issue was discovered in Scytl sVote 2.1. Because the sdm-ws-rest API does not require authentication, an attacker can retrieve the administrative configuration by sending a POST request to the /sdm-ws-rest/preconfiguration URI.
A Missing Authentication for Critical Function vulnerability combined with a Generation of Error Message Containing Sensitive Information vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an unauthenticated, network-based attacker to access sensitive system information. When a user logs in, a temporary file which contains the configuration of the device (as visible to that user) is created in the /cache folder. An unauthenticated attacker can then attempt to access such a file by sending a specific request to the device trying to guess the name of such a file. Successful exploitation will reveal configuration information. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S7; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R1-S2, 23.2R2.
A missing authentication check in the WebSocket channel used for the Check Point IoT integration in Nozomi Networks Guardian and CMC, may allow an unauthenticated attacker to obtain assets data without authentication. Malicious unauthenticated users with knowledge on the underlying system may be able to extract limited asset information.
Certain HP DesignJet products may be vulnerable to credential reflection which allow viewing SMTP server credentials.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
In core/doctype/prepared_report/prepared_report.py in Frappe 11 and 12, data files generated with Prepared Report were being stored as public files (no authentication is required to access; having a link is sufficient) instead of private files.
Incorrect access control in the component l_0_0.xml of TP-Link ARCHER-C7 v5 allows attackers to access sensitive information.
MachineSense devices use unauthenticated MQTT messaging to monitor devices and remote viewing of sensor data by users.
An issue in Plug n Play Camera com.starvedia.mCamView.zwave 5.5.1 allows a remote attacker to obtain sensitive information via the firmware update process
An issue in almando GmbH Almando Play APP (com.almando.play) 1.8.2 allows a remote attacker to obtain sensitive information via the firmware update process
Broadcom RAID Controller Web server (nginx) is serving private server-side files without any authentication on Linux
The issue was addressed with additional permissions checks. This issue is fixed in macOS Ventura 13.6.1. An attacker may be able to access passkeys without authentication.
ironic-image is a container image to run OpenStack Ironic as part of Metal³. Prior to version capm3-v1.4.3, if Ironic is not deployed with TLS and it does not have API and Conductor split into separate services, access to the API is not protected by any authentication. Ironic API is also listening in host network. In case the node is not behind a firewall, the API could be accessed by anyone via network without authentication. By default, Ironic API in Metal3 is protected by TLS and basic authentication, so this vulnerability requires operator to configure API without TLS for it to be vulnerable. TLS and authentication however should not be coupled as they are in versions prior to capm3-v1.4.3. A patch exists in versions capm3-v1.4.3 and newer. Some workarounds are available. Either configure TLS for Ironic API (`deploy.sh -t ...`, `IRONIC_TLS_SETUP=true`) or split Ironic API and Conductor via configuration change (old implementation, not recommended). With both workarounds, services are configured with httpd front-end, which has proper authentication configuration in place.
Walchem Intuition 9 firmware versions prior to v4.21 are missing authentication for some of the API routes of the management web server. This could allow an attacker to download and export sensitive data.
Saho’s attendance devices ADM100 and ADM-100FP have a vulnerability of missing authentication for critical functions. An unauthenticated remote attacker can execute system commands in partial website URLs to read sensitive device information without permissions.
A broken authentication mechanism in the endpoint excel.php of POS Codekop v2.0 allows unauthenticated attackers to download selling data.
ChuanhuChatGPT is a graphical user interface for ChatGPT and many large language models. A vulnerability in versions 20230526 and prior allows unauthorized access to the config.json file of the privately deployed ChuanghuChatGPT project, when authentication is not configured. The attacker can exploit this vulnerability to steal the API keys in the configuration file. The vulnerability has been fixed in commit bfac445. As a workaround, setting up access authentication can help mitigate the vulnerability.
A vulnerability was found in CodeAstro House Rental Management System 1.0. It has been rated as problematic. Affected by this issue is some unknown functionality of the file booking.php/owner.php/tenant.php. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-255392.
In Talend Studio before 7.3.1-R2022-10 and 8.x before 8.0.1-R2022-09, microservices allow unauthenticated access to the Jolokia endpoint of the microservice. This allows for remote access to the JVM via the Jolokia JMX-HTTP bridge.
All configuration parameters of certain Kyocera printers (such as the ECOSYS M5526cdw 2R7_2000.001.701) were accessible by unauthenticated users. This information was only presented in the menus when authenticated, and the pages that loaded this information were also protected. However, all files that contained the configuration parameters were accessible. These files contained sensitive information, such as users, community strings, and other passwords configured in the printer.
An unauthenticated remote attacker can get read access to files in the "/tmp" directory due to missing authentication.
An issue in Shelly com.home.shelly 1.0.4 allows a remote attacker to obtain sensitive information via the firmware update process
BigAnt Software BigAnt Server v5.6.06 was discovered to contain incorrect access control.
Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network.
A certain router administration interface (that includes Realtek APMIB 0.11f for Boa 0.94.14rc21) allows remote attackers to retrieve the configuration, including sensitive data (usernames and passwords). This affects TOTOLINK A3002RU through 2.0.0, A702R through 2.1.3, N301RT through 2.1.6, N302R through 3.4.0, N300RT through 3.4.0, N200RE through 4.0.0, N150RT through 3.4.0, and N100RE through 3.4.0; Rutek RTK 11N AP through 2019-12-12; Sapido GR297n through 2019-12-12; CIK TELECOM MESH ROUTER through 2019-12-12; KCTVJEJU Wireless AP through 2019-12-12; Fibergate FGN-R2 through 2019-12-12; Hi-Wifi MAX-C300N through 2019-12-12; HCN MAX-C300N through 2019-12-12; T-broad GN-866ac through 2019-12-12; Coship EMTA AP through 2019-12-12; and IO-Data WN-AC1167R through 2019-12-12.
IBM Security Guardium 10.5, 10.6, and 11.0 could allow an unauthorized user to obtain sensitive information due to missing security controls. IBM X-Force ID: 141226.
Wipro Holmes Orchestrator 20.4.1 (20.4.1_02_11_2020) allows remote attackers to read application log files containing sensitive information via a predictable /log URI.
An issue was discovered in the Infosysta "In-App & Desktop Notifications" app 1.6.13_J8 for Jira. By using plugins/servlet/nfj/PushNotification?username= with a modified username, a different user's notifications can be read without authentication/authorization. These notifications are then no longer displayed to the normal user.
An unauthenticated attacker with access to the local network of the medical office can query an unprotected Fast Healthcare Interoperability Resources (FHIR) API to get access to sensitive electronic health records (EHR).