Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-28384

Summary
Assigner-icscert
Assigner Org ID-7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At-27 Apr, 2023 | 22:09
Updated At-17 Jan, 2025 | 17:05
Rejected At-
Credits

CVE-2023-28384

mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:icscert
Assigner Org ID:7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At:27 Apr, 2023 | 22:09
Updated At:17 Jan, 2025 | 17:05
Rejected At:
▼CVE Numbering Authority (CNA)
CVE-2023-28384

mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.

Affected Products
Vendor
mySCADA Technologies
Product
mySCADA myPRO
Versions
Affected
  • From 0 through 8.26.0 (custom)
Problem Types
TypeCWE IDDescription
N/AN/ACWE-78 OS Command Injection
Type: N/A
CWE ID: N/A
Description: CWE-78 OS Command Injection
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-096-06
N/A
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-096-06
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-096-06
x_transferred
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-096-06
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:ics-cert@hq.dhs.gov
Published At:27 Apr, 2023 | 23:15
Updated At:17 Jan, 2025 | 17:15

mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

myscada
myscada
>>mypro>>Versions up to 8.26.0(inclusive)
cpe:2.3:a:myscada:mypro:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-78Primarynvd@nist.gov
CWE ID: CWE-78
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-096-06ics-cert@hq.dhs.gov
Third Party Advisory
US Government Resource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-096-06af854a3a-2127-422b-91ae-364da2661108
Third Party Advisory
US Government Resource
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-096-06
Source: ics-cert@hq.dhs.gov
Resource:
Third Party Advisory
US Government Resource
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-096-06
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Third Party Advisory
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

781Records found

CVE-2021-42372
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.49% / 88.67%
||
7 Day CHG~0.00%
Published-08 Nov, 2021 | 04:44
Updated-04 Aug, 2024 | 03:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A shell command injection in the HW Events SNMP community in XoruX LPAR2RRD and STOR2RRD before 7.30 allows authenticated remote attackers to execute arbitrary shell commands as the user running the service.

Action-Not Available
Vendor-xoruxn/a
Product-lpar2rrdstor2rrdn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-42165
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-39.55% / 97.20%
||
7 Day CHG~0.00%
Published-03 May, 2022 | 11:25
Updated-04 Aug, 2024 | 03:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

MitraStar GPT-2541GNAC-N1 (HGU) 100VNZ0b33 devices allow remote authenticated users to obtain root access by executing command "deviceinfo show file &&/bin/bash" because of incorrect sanitization of parameter "path".

Action-Not Available
Vendor-mitrastarn/a
Product-gpt-2541gnac-n1gpt-2541gnac-n1_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-55590
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-8.6||HIGH
EPSS-0.15% / 35.77%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 14:54
Updated-23 Jul, 2025 | 15:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerabilities [CWE-78] in Fortinet FortiIsolator version 2.4.0 through 2.4.5 allows an authenticated attacker with at least read-only admin permission and CLI access to execute unauthorized code via specifically crafted CLI commands.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortiisolatorFortiIsolator
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5987
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-8.8||HIGH
EPSS-2.63% / 85.12%
||
7 Day CHG~0.00%
Published-06 Jan, 2020 | 05:45
Updated-04 Aug, 2024 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Access analysis CGI An-Analyzer released in 2019 June 24 and earlier allows remote authenticated attackers to execute arbitrary OS commands via the Management Page.

Action-Not Available
Vendor-ANGLERSNET
Product-cgi_an-anlyzerAccess analysis CGI An-Analyzer
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-41315
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.63% / 69.34%
||
7 Day CHG~0.00%
Published-17 Sep, 2021 | 14:46
Updated-04 Aug, 2024 | 03:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Device42 Remote Collector before 17.05.01 does not sanitize user input in its SNMP Connectivity utility. This allows an authenticated attacker (with access to the console application) to execute arbitrary OS commands and escalate privileges.

Action-Not Available
Vendor-device42n/a
Product-remote_collectorn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-4144
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-8.8||HIGH
EPSS-1.77% / 81.91%
||
7 Day CHG~0.00%
Published-23 Dec, 2021 | 06:30
Updated-03 Aug, 2024 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TP-Link wifi router TL-WR802N V4(JP), with firmware version prior to 211202, is vulnerable to OS command injection.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-tl-wr802n_firmwaretl-wr802nTL-WR802N V4(JP)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5424
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-1.86% / 82.30%
||
7 Day CHG~0.00%
Published-10 Apr, 2019 | 17:31
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, a privileged user can execute arbitrary shell commands over the SSH CLI interface. This allows to execute shell commands under the root user.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgeswitch_xEdgeMAX
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-41016
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-7.8||HIGH
EPSS-0.81% / 73.22%
||
7 Day CHG~0.00%
Published-02 Feb, 2022 | 10:58
Updated-25 Oct, 2024 | 13:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A improper neutralization of special elements used in a command ('command injection') in Fortinet FortiExtender version 7.0.1 and below, 4.2.3 and below, 4.1.7 and below allows an authenticated attacker to execute privileged shell commands via CLI commands including special characters

Action-Not Available
Vendor-n/aFortinet, Inc.
Product-fortiextender_firmwarefortiextendern/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-44342
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.25% / 48.34%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 00:00
Updated-30 Aug, 2024 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via the wl(0).(0)_ssid parameter. This vulnerability is exploited via a crafted POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-846w_firmwaredir-846wn/adir-846w_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-44341
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.99% / 75.90%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 00:00
Updated-30 Aug, 2024 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via the lan(0)_dhcps_staticlist parameter. This vulnerability is exploited via a crafted POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-846w_firmwaredir-846wn/adir-846w_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5141
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-3.37% / 86.85%
||
7 Day CHG~0.00%
Published-25 Feb, 2020 | 15:26
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the iw_webs functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted iw_serverip parameter can cause user input to be reflected in a subsequent iw_system call, resulting in remote control over the device. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-awk-3131aawk-3131a_firmwareMoxa
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-41738
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.04% / 88.03%
||
7 Day CHG~0.00%
Published-11 Jun, 2022 | 13:26
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ZeroShell 3.9.5 has a command injection vulnerability in /cgi-bin/kerbynet IP parameter, which may allow an authenticated attacker to execute system commands.

Action-Not Available
Vendor-zeroshelln/a
Product-zeroshelln/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-44340
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.54% / 66.52%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 00:00
Updated-30 Aug, 2024 | 14:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via keys smartqos_express_devices and smartqos_normal_devices in SetSmartQoSSettings.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-846w_firmwaredir-846wn/adir-846w_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2013-1598
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-32.16% / 96.68%
||
7 Day CHG~0.00%
Published-24 Jan, 2020 | 18:32
Updated-06 Aug, 2024 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code.

Action-Not Available
Vendor-vivotekn/a
Product-pt7135_firmwarept7135n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-44844
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-9.59% / 92.56%
||
7 Day CHG~0.00%
Published-06 Sep, 2024 | 00:00
Updated-11 Sep, 2024 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

DrayTek Vigor3900 v1.5.1.6 was discovered to contain an authenticated command injection vulnerability via the name parameter in the run_command function.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-vigor3900_firmwarevigor3900n/avigor3900_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42742
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-12.76% / 93.74%
||
7 Day CHG~0.00%
Published-12 Aug, 2024 | 00:00
Updated-13 Aug, 2024 | 20:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setUrlFilterRules. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-13851
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-91.61% / 99.66%
||
7 Day CHG-0.47%
Published-11 Jun, 2020 | 02:15
Updated-04 Aug, 2024 | 12:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Artica Pandora FMS 7.44 allows remote command execution via the events feature.

Action-Not Available
Vendor-n/aPandora FMS S.L.U.
Product-pandora_fmsn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42741
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-9.02% / 92.29%
||
7 Day CHG~0.00%
Published-12 Aug, 2024 | 00:00
Updated-13 Aug, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setL2tpServerCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-13778
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.69% / 70.88%
||
7 Day CHG~0.00%
Published-19 Oct, 2020 | 12:54
Updated-04 Aug, 2024 | 12:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

rConfig 3.9.4 and earlier allows authenticated code execution (of system commands) by sending a forged GET request to lib/ajaxHandlers/ajaxAddTemplate.php or lib/ajaxHandlers/ajaxEditTemplate.php.

Action-Not Available
Vendor-rconfign/a
Product-rconfign/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43657
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
ShareView Details
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
CVSS Score-9.3||CRITICAL
EPSS-1.48% / 80.20%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 07:56
Updated-11 Mar, 2025 | 13:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
When uploading new firmware, a shell script inside a firmware file is executed during its processing. This can be used to craft a custom firmware file with a custom script with arbitrary code, which will then be executed on the charging station.

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Action-Not Available
Vendor-Iocharger
Product-Iocharger firmware for AC models
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-19642
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-25.95% / 96.06%
||
7 Day CHG~0.00%
Published-08 Dec, 2019 | 03:39
Updated-05 Aug, 2024 | 02:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On SuperMicro X8STi-F motherboards with IPMI firmware 2.06 and BIOS 02.68, the Virtual Media feature allows OS Command Injection by authenticated attackers who can send HTTP requests to the IPMI IP address. This requires a POST to /rpc/setvmdrive.asp with shell metacharacters in ShareHost or ShareName. The attacker can achieve a persistent backdoor.

Action-Not Available
Vendor-supermicron/a
Product-x8sti-fx8sti-f_biosx8sti-f_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-12111
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.51% / 88.69%
||
7 Day CHG~0.00%
Published-04 May, 2020 | 14:05
Updated-04 Aug, 2024 | 11:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain TP-Link devices allow Command Injection. This affects NC260 1.5.2 build 200304 and NC450 1.5.3 build 200304.

Action-Not Available
Vendor-n/aTP-Link Systems Inc.
Product-nc260_firmwarenc450_firmwarenc260nc450n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43656
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
ShareView Details
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
CVSS Score-9.3||CRITICAL
EPSS-1.48% / 80.20%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 07:56
Updated-11 Mar, 2025 | 13:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
A backup can be manipulated and then restored to create arbitrary files inside the <redacted> directory. A CGI script can be added to the web directory this way, allowing for full remote code execution.

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Action-Not Available
Vendor-Iocharger
Product-Iocharger firmware for AC models
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43649
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
ShareView Details
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
CVSS Score-9.3||CRITICAL
EPSS-0.81% / 73.32%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 07:56
Updated-11 Mar, 2025 | 13:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated command injection via <redacted>.exe <redacted> parameter

Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).

Action-Not Available
Vendor-Iocharger
Product-Iocharger firmware for AC models
CWE ID-CWE-250
Execution with Unnecessary Privileges
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-11978
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-8.8||HIGH
EPSS-94.27% / 99.93%
||
7 Day CHG~0.00%
Published-16 Jul, 2020 | 00:00
Updated-30 Jul, 2025 | 01:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-07-18||Apply updates per vendor instructions.

An issue was found in Apache Airflow versions 1.10.10 and below. A remote code/command injection vulnerability was discovered in one of the example DAGs shipped with Airflow which would allow any authenticated user to run arbitrary commands as the user running airflow worker/scheduler (depending on the executor in use). If you already have examples disabled by setting load_examples=False in the config then you are not vulnerable.

Action-Not Available
Vendor-The Apache Software Foundation
Product-airflowApache AirflowAirflow
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-3417
Matching Score-4
Assigner-ZTE Corporation
ShareView Details
Matching Score-4
Assigner-ZTE Corporation
CVSS Score-8.1||HIGH
EPSS-1.55% / 80.66%
||
7 Day CHG~0.00%
Published-15 Aug, 2019 | 14:43
Updated-04 Aug, 2024 | 19:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

All versions up to V1.1.10P3T18 of ZTE ZXHN F670 product are impacted by command injection vulnerability. Due to insufficient parameter validation check, an authorized user can exploit this vulnerability to take control of user router system.

Action-Not Available
Vendor-ZTE Corporation
Product-zxhn_f670_firmwarezxhn_f670ZXHN F670
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43652
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
ShareView Details
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
CVSS Score-9.3||CRITICAL
EPSS-2.67% / 85.22%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 07:56
Updated-11 Mar, 2025 | 13:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.

Action-Not Available
Vendor-Iocharger
Product-Iocharger firmware for AC chargers
CWE ID-CWE-250
Execution with Unnecessary Privileges
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42747
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.3||HIGH
EPSS-2.08% / 83.29%
||
7 Day CHG~0.00%
Published-12 Aug, 2024 | 00:00
Updated-13 Aug, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setWanIeCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43385
Matching Score-4
Assigner-CERT@VDE
ShareView Details
Matching Score-4
Assigner-CERT@VDE
CVSS Score-8.8||HIGH
EPSS-1.15% / 77.61%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 08:43
Updated-27 Sep, 2024 | 19:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Phoenix Contact: OS command execution through PROXY_HTTP_PORT in mGuard devices

A low privileged remote attacker can trigger the execution of arbitrary OS commands as root due to improper neutralization of special elements in the variable PROXY_HTTP_PORT in mGuard devices.

Action-Not Available
Vendor-Phoenix Contact GmbH & Co. KG
Product-fl_mguard_2105_firmwaretc_mguard_rs2000_4g_vpnfl_mguard_2102fl_mguard_4102_pci_firmwarefl_mguard_4302_firmwarefl_mguard_pcie4000_vpn_firmwarefl_mguard_rs2000_tx\/tx-b_firmwarefl_mguard_4102_pcie_firmwarefl_mguard_rs4000_tx\/txfl_mguard_pcie4000_firmwarefl_mguard_4305_firmwarefl_mguard_rs4000_tx\/tx_firmwaretc_mguard_rs4000_3g_vpn_firmwarefl_mguard_rs4004_tx\/dtx_vpn_firmwarefl_mguard_rs4004_tx\/dtx_firmwarefl_mguard_pcie4000tc_mguard_rs4000_4g_vzw_vpn_firmwarefl_mguard_core_tx_vpntc_mguard_rs2000_4g_att_vpn_firmwarefl_mguard_delta_tx\/txfl_mguard_4302fl_mguard_rs4000_tx\/tx_vpn_firmwarefl_mguard_rs2000_tx\/tx_vpn_firmwarefl_mguard_rs2000_tx\/tx-btc_mguard_rs4000_4g_att_vpntc_mguard_rs2000_3g_vpnfl_mguard_rs2005_tx_vpntc_mguard_rs4000_4g_vpnfl_mguard_4102_pcifl_mguard_gt\/gt_firmwarefl_mguard_gt\/gt_vpn_firmwarefl_mguard_core_tx_vpn_firmwaretc_mguard_rs2000_4g_vzw_vpnfl_mguard_rs4004_tx\/dtxfl_mguard_delta_tx\/tx_vpn_firmwarefl_mguard_rs4000_tx\/tx-pfl_mguard_2105fl_mguard_4305fl_mguard_pci4000_firmwaretc_mguard_rs2000_3g_vpn_firmwaretc_mguard_rs4000_4g_vpn_firmwarefl_mguard_core_tx_firmwaretc_mguard_rs4000_4g_att_vpn_firmwarefl_mguard_gt\/gt_vpnfl_mguard_centerport_vpn-1000fl_mguard_pcie4000_vpnfl_mguard_2102_firmwarefl_mguard_centerport_vpn-1000_firmwarefl_mguard_rs2000_tx\/tx_vpntc_mguard_rs2000_4g_vpn_firmwarefl_mguard_rs4000_tx\/tx-m_firmwarefl_mguard_smart2_vpnfl_mguard_smart2fl_mguard_rs2005_tx_vpn_firmwaretc_mguard_rs2000_4g_att_vpnfl_mguard_smart2_vpn_firmwarefl_mguard_rs4000_tx\/tx-mfl_mguard_smart2_firmwarefl_mguard_delta_tx\/tx_firmwarefl_mguard_pci4000fl_mguard_pci4000_vpn_firmwarefl_mguard_delta_tx\/tx_vpntc_mguard_rs4000_4g_vzw_vpnfl_mguard_rs4000_tx\/tx_vpntc_mguard_rs2000_4g_vzw_vpn_firmwarefl_mguard_rs4004_tx\/dtx_vpnfl_mguard_gt\/gtfl_mguard_4102_pciefl_mguard_core_txtc_mguard_rs4000_3g_vpnfl_mguard_rs4000_tx\/tx-p_firmwarefl_mguard_pci4000_vpnFL MGUARD 4102 PCIETC MGUARD RS4000 4G VPNFL MGUARD RS2000 TX/TX VPNTC MGUARD RS2000 4G ATT VPNFL MGUARD 4305FL MGUARD RS4004 TX/DTXTC MGUARD RS2000 3G VPNTC MGUARD RS4000 4G VZW VPNFL MGUARD DELTA TX/TXFL MGUARD PCIE4000FL MGUARD SMART2 VPNFL MGUARD CORE TXFL MGUARD RS4000 TX/TXFL MGUARD RS4000 TX/TX-PFL MGUARD RS2000 TX/TX-BFL MGUARD 2102FL MGUARD RS2005 TX VPNFL MGUARD PCIE4000 VPNFL MGUARD 4102 PCIFL MGUARD CENTERPORT VPN-1000FL MGUARD DELTA TX/TX VPNFL MGUARD RS4000 TX/TX VPNFL MGUARD RS4004 TX/DTX VPNFL MGUARD PCI4000 VPNFL MGUARD GT/GTFL MGUARD 2105TC MGUARD RS4000 3G VPNFL MGUARD CORE TX VPNTC MGUARD RS4000 4G ATT VPNFL MGUARD RS4000 TX/TX-MFL MGUARD 4302FL MGUARD SMART2FL MGUARD GT/GT VPNFL MGUARD PCI4000TC MGUARD RS2000 4G VPNTC MGUARD RS2000 4G VZW VPNfl_mguard_smart2_vpn_firmwaretc_mguard_rs4000_4g_vzw_vpn_firmwarefl_mguard_4305_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43386
Matching Score-4
Assigner-CERT@VDE
ShareView Details
Matching Score-4
Assigner-CERT@VDE
CVSS Score-8.8||HIGH
EPSS-1.15% / 77.61%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 08:43
Updated-27 Sep, 2024 | 19:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Phoenix Contact: OS command execution through EMAIL_NOTIFICATION.TO in mGuard devices.

A low privileged remote attacker can trigger the execution of arbitrary OS commands as root due to improper neutralization of special elements in the variable EMAIL_NOTIFICATION.TO in mGuard devices.

Action-Not Available
Vendor-Phoenix Contact GmbH & Co. KG
Product-fl_mguard_2105_firmwaretc_mguard_rs2000_4g_vpnfl_mguard_2102fl_mguard_4102_pci_firmwarefl_mguard_4302_firmwarefl_mguard_pcie4000_vpn_firmwarefl_mguard_rs2000_tx\/tx-b_firmwarefl_mguard_4102_pcie_firmwarefl_mguard_rs4000_tx\/txfl_mguard_pcie4000_firmwarefl_mguard_4305_firmwarefl_mguard_rs4000_tx\/tx_firmwaretc_mguard_rs4000_3g_vpn_firmwarefl_mguard_rs4004_tx\/dtx_vpn_firmwarefl_mguard_rs4004_tx\/dtx_firmwarefl_mguard_pcie4000tc_mguard_rs4000_4g_vzw_vpn_firmwarefl_mguard_core_tx_vpntc_mguard_rs2000_4g_att_vpn_firmwarefl_mguard_delta_tx\/txfl_mguard_4302fl_mguard_rs4000_tx\/tx_vpn_firmwarefl_mguard_rs2000_tx\/tx_vpn_firmwarefl_mguard_rs2000_tx\/tx-btc_mguard_rs4000_4g_att_vpntc_mguard_rs2000_3g_vpnfl_mguard_rs2005_tx_vpntc_mguard_rs4000_4g_vpnfl_mguard_4102_pcifl_mguard_gt\/gt_firmwarefl_mguard_gt\/gt_vpn_firmwarefl_mguard_core_tx_vpn_firmwaretc_mguard_rs2000_4g_vzw_vpnfl_mguard_rs4004_tx\/dtxfl_mguard_delta_tx\/tx_vpn_firmwarefl_mguard_rs4000_tx\/tx-pfl_mguard_2105fl_mguard_4305fl_mguard_pci4000_firmwaretc_mguard_rs2000_3g_vpn_firmwaretc_mguard_rs4000_4g_vpn_firmwarefl_mguard_core_tx_firmwaretc_mguard_rs4000_4g_att_vpn_firmwarefl_mguard_gt\/gt_vpnfl_mguard_centerport_vpn-1000fl_mguard_pcie4000_vpnfl_mguard_2102_firmwarefl_mguard_centerport_vpn-1000_firmwarefl_mguard_rs2000_tx\/tx_vpntc_mguard_rs2000_4g_vpn_firmwarefl_mguard_rs4000_tx\/tx-m_firmwarefl_mguard_smart2_vpnfl_mguard_smart2fl_mguard_rs2005_tx_vpn_firmwaretc_mguard_rs2000_4g_att_vpnfl_mguard_smart2_vpn_firmwarefl_mguard_rs4000_tx\/tx-mfl_mguard_smart2_firmwarefl_mguard_delta_tx\/tx_firmwarefl_mguard_pci4000fl_mguard_pci4000_vpn_firmwarefl_mguard_delta_tx\/tx_vpntc_mguard_rs4000_4g_vzw_vpnfl_mguard_rs4000_tx\/tx_vpntc_mguard_rs2000_4g_vzw_vpn_firmwarefl_mguard_rs4004_tx\/dtx_vpnfl_mguard_gt\/gtfl_mguard_4102_pciefl_mguard_core_txtc_mguard_rs4000_3g_vpnfl_mguard_rs4000_tx\/tx-p_firmwarefl_mguard_pci4000_vpnFL MGUARD 4102 PCIETC MGUARD RS4000 4G VPNFL MGUARD RS2000 TX/TX VPNTC MGUARD RS2000 4G ATT VPNFL MGUARD 4305FL MGUARD RS4004 TX/DTXTC MGUARD RS2000 3G VPNTC MGUARD RS4000 4G VZW VPNFL MGUARD DELTA TX/TXFL MGUARD PCIE4000FL MGUARD SMART2 VPNFL MGUARD CORE TXFL MGUARD RS4000 TX/TXFL MGUARD RS4000 TX/TX-PFL MGUARD RS2000 TX/TX-BFL MGUARD 2102FL MGUARD RS2005 TX VPNFL MGUARD PCIE4000 VPNFL MGUARD 4102 PCIFL MGUARD CENTERPORT VPN-1000FL MGUARD DELTA TX/TX VPNFL MGUARD RS4000 TX/TX VPNFL MGUARD RS4004 TX/DTX VPNFL MGUARD PCI4000 VPNFL MGUARD GT/GTFL MGUARD 2105TC MGUARD RS4000 3G VPNFL MGUARD CORE TX VPNTC MGUARD RS4000 4G ATT VPNFL MGUARD RS4000 TX/TX-MFL MGUARD 4302FL MGUARD SMART2FL MGUARD GT/GT VPNFL MGUARD PCI4000TC MGUARD RS2000 4G VPNTC MGUARD RS2000 4G VZW VPNfl_mguard_smart2_vpn_firmwaretc_mguard_rs4000_4g_vzw_vpn_firmwarefl_mguard_4305_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42738
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-16.40% / 94.61%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 00:00
Updated-14 Aug, 2024 | 16:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setDmzCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2012-6610
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.23% / 83.86%
||
7 Day CHG~0.00%
Published-28 Jan, 2020 | 16:28
Updated-06 Aug, 2024 | 21:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Polycom HDX Video End Points before 3.0.4 and UC APL before 2.7.1.J allows remote authenticated users to execute arbitrary commands as demonstrated by a ; (semicolon) to the ping command feature.

Action-Not Available
Vendor-polycomn/a
Product-hdx_video_end_pointsuc_aplhdx_8000n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43804
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-1.40% / 79.62%
||
7 Day CHG~0.00%
Published-29 Aug, 2024 | 16:45
Updated-06 Sep, 2024 | 22:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
OS Command Injection via Port Scan Functionality in Roxy-WI

Roxy-WI is a web interface for managing Haproxy, Nginx, Apache and Keepalived servers. An OS Command Injection vulnerability allows any authenticated user on the application to execute arbitrary code on the web application server via port scanning functionality. User-supplied input is used without validation when constructing and executing an OS command. User supplied JSON POST data is parsed and if "id" JSON key does not exist, JSON value supplied via "ip" JSON key is assigned to the "ip" variable. Later on, "ip" variable which can be controlled by the attacker is used when constructing the cmd and cmd1 strings without any extra validation. Then, server_mod.subprocess_execute function is called on both cmd1 and cmd2. When the definition of the server_mod.subprocess_execute() function is analyzed, it can be seen that subprocess.Popen() is called on the input parameter with shell=True which results in OS Command Injection. This issue has not yet been patched. Users are advised to contact the Roxy-WI to coordinate a fix.

Action-Not Available
Vendor-roxy-wiroxy-wiroxy-wi
Product-roxy-wiroxy-wiroxy-wi
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43654
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
ShareView Details
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
CVSS Score-9.3||CRITICAL
EPSS-2.21% / 83.77%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 07:56
Updated-11 Mar, 2025 | 13:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Action-Not Available
Vendor-Iocharger
Product-Iocharger firmware for AC models
CWE ID-CWE-250
Execution with Unnecessary Privileges
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-14432
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.8||HIGH
EPSS-0.65% / 69.77%
||
7 Day CHG~0.00%
Published-14 May, 2018 | 20:00
Updated-16 Sep, 2024 | 17:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the web server functionality of Moxa EDR-810 V4.1 build 17030317. A specially crafted HTTP POST can cause a privilege escalation resulting in root shell. An attacker can inject OS commands into the openvpnServer0_tmp= parameter in the "/goform/net\_Web\_get_value" uri to trigger this vulnerability.

Action-Not Available
Vendor-Moxa Inc.Talos (Cisco Systems, Inc.)
Product-edr-810_firmwareedr-810Moxa
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43653
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
ShareView Details
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
CVSS Score-9.3||CRITICAL
EPSS-2.21% / 83.77%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 07:56
Updated-11 Mar, 2025 | 13:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated command injection in the <redacted> action leads to full remote code execution as root on the charging station

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Action-Not Available
Vendor-Iocharger
Product-Iocharger firmware for AC models
CWE ID-CWE-250
Execution with Unnecessary Privileges
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-4715
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-8.8||HIGH
EPSS-5.05% / 89.36%
||
7 Day CHG~0.00%
Published-11 Dec, 2019 | 14:25
Updated-16 Sep, 2024 | 22:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Spectrum Scale 4.2 and 5.0 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially-crafted request, an attacker could exploit this vulnerability to execute arbitrary commands on the system. IBM X-Force ID: 172093.

Action-Not Available
Vendor-IBM Corporation
Product-spectrum_scaleSpectrum Scale
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43648
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
ShareView Details
Matching Score-4
Assigner-Dutch Institute for Vulnerability Disclosure (DIVD)
CVSS Score-9.3||CRITICAL
EPSS-1.36% / 79.35%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 07:56
Updated-11 Mar, 2025 | 13:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated command injection via <redacted>.exe <redacted> parameter

Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).

Action-Not Available
Vendor-Iocharger
Product-Iocharger firmware for AC models
CWE ID-CWE-250
Execution with Unnecessary Privileges
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-14535
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-91.39% / 99.65%
||
7 Day CHG~0.00%
Published-16 Feb, 2018 | 04:00
Updated-05 Aug, 2024 | 19:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

trixbox 2.8.0.4 has OS command injection via shell metacharacters in the lang parameter to /maint/modules/home/index.php.

Action-Not Available
Vendor-netfortrisn/a
Product-trixboxn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-4301
Matching Score-4
Assigner-TWCERT/CC
ShareView Details
Matching Score-4
Assigner-TWCERT/CC
CVSS Score-8.8||HIGH
EPSS-1.17% / 77.84%
||
7 Day CHG~0.00%
Published-29 Apr, 2024 | 04:01
Updated-01 Aug, 2024 | 20:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
N-Reporter and N-Cloud from N-Partner - Os Command Injection

N-Reporter and N-Cloud, products of the N-Partner, have an OS Command Injection vulnerability. Remote attackers with normal user privilege can execute arbitrary system commands by manipulating user inputs on a specific page.

Action-Not Available
Vendor-N-Partnern-partner
Product-N-Reporter firmwareN-Cloud firmwaren-cloud_firmwaren-reporter_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-39244
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-16.20% / 94.55%
||
7 Day CHG~0.00%
Published-23 Aug, 2021 | 04:26
Updated-04 Aug, 2024 | 02:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Authenticated Semi-Blind Command Injection (via Parameter Injection) exists on Altus Nexto, Nexto Xpress, and Hadron Xtorm devices via the getlogs.cgi tcpdump feature. This affects Nexto NX3003 1.8.11.0, Nexto NX3004 1.8.11.0, Nexto NX3005 1.8.11.0, Nexto NX3010 1.8.3.0, Nexto NX3020 1.8.3.0, Nexto NX3030 1.8.3.0, Nexto NX5100 1.8.11.0, Nexto NX5101 1.8.11.0, Nexto NX5110 1.1.2.8, Nexto NX5210 1.1.2.8, Nexto Xpress XP300 1.8.11.0, Nexto Xpress XP315 1.8.11.0, Nexto Xpress XP325 1.8.11.0, Nexto Xpress XP340 1.8.11.0, and Hadron Xtorm HX3040 1.7.58.0.

Action-Not Available
Vendor-altusn/a
Product-nexto_nx3004nexto_nx3005nexto_nx5101_firmwarenexto_xpress_xp315hadron_xtorm_hx3040_firmwarenexto_nx3003_firmwarenexto_xpress_xp300nexto_nx3010_firmwarenexto_xpress_xp325nexto_nx5100nexto_xpress_xp315_firmwarenexto_xpress_xp325_firmwarenexto_nx3020hadron_xtorm_hx3040nexto_xpress_xp340nexto_nx3030_firmwarenexto_nx5210nexto_nx5110_firmwarenexto_xpress_xp300_firmwarenexto_nx3010nexto_nx3004_firmwarenexto_nx5100_firmwarenexto_xpress_xp340_firmwarenexto_nx3020_firmwarenexto_nx3003nexto_nx5210_firmwarenexto_nx5101nexto_nx3030nexto_nx3005_firmwarenexto_nx5110n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42737
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-20.36% / 95.32%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 00:00
Updated-13 Aug, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in delBlacklist. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43387
Matching Score-4
Assigner-CERT@VDE
ShareView Details
Matching Score-4
Assigner-CERT@VDE
CVSS Score-8.8||HIGH
EPSS-0.41% / 60.75%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 08:43
Updated-27 Sep, 2024 | 19:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Phoenix Contact: Access files due to improper neutralization of special elements in MGUARD devices

A low privileged remote attacker can read and write files as root due to improper neutralization of special elements in the variable EMAIL_RELAY_PASSWORD in mGuard devices.

Action-Not Available
Vendor-Phoenix Contact GmbH & Co. KG
Product-fl_mguard_2105_firmwaretc_mguard_rs2000_4g_vpnfl_mguard_2102fl_mguard_4102_pci_firmwarefl_mguard_4302_firmwarefl_mguard_pcie4000_vpn_firmwarefl_mguard_rs2000_tx\/tx-b_firmwarefl_mguard_4102_pcie_firmwarefl_mguard_rs4000_tx\/txfl_mguard_pcie4000_firmwarefl_mguard_4305_firmwarefl_mguard_rs4000_tx\/tx_firmwaretc_mguard_rs4000_3g_vpn_firmwarefl_mguard_rs4004_tx\/dtx_vpn_firmwarefl_mguard_rs4004_tx\/dtx_firmwarefl_mguard_pcie4000tc_mguard_rs4000_4g_vzw_vpn_firmwarefl_mguard_core_tx_vpntc_mguard_rs2000_4g_att_vpn_firmwarefl_mguard_delta_tx\/txfl_mguard_4302fl_mguard_rs4000_tx\/tx_vpn_firmwarefl_mguard_rs2000_tx\/tx_vpn_firmwarefl_mguard_rs2000_tx\/tx-btc_mguard_rs4000_4g_att_vpntc_mguard_rs2000_3g_vpnfl_mguard_rs2005_tx_vpntc_mguard_rs4000_4g_vpnfl_mguard_4102_pcifl_mguard_gt\/gt_firmwarefl_mguard_gt\/gt_vpn_firmwarefl_mguard_core_tx_vpn_firmwaretc_mguard_rs2000_4g_vzw_vpnfl_mguard_rs4004_tx\/dtxfl_mguard_delta_tx\/tx_vpn_firmwarefl_mguard_rs4000_tx\/tx-pfl_mguard_2105fl_mguard_4305fl_mguard_pci4000_firmwaretc_mguard_rs2000_3g_vpn_firmwaretc_mguard_rs4000_4g_vpn_firmwarefl_mguard_core_tx_firmwaretc_mguard_rs4000_4g_att_vpn_firmwarefl_mguard_gt\/gt_vpnfl_mguard_centerport_vpn-1000fl_mguard_pcie4000_vpnfl_mguard_2102_firmwarefl_mguard_centerport_vpn-1000_firmwarefl_mguard_rs2000_tx\/tx_vpntc_mguard_rs2000_4g_vpn_firmwarefl_mguard_rs4000_tx\/tx-m_firmwarefl_mguard_smart2_vpnfl_mguard_smart2fl_mguard_rs2005_tx_vpn_firmwaretc_mguard_rs2000_4g_att_vpnfl_mguard_smart2_vpn_firmwarefl_mguard_rs4000_tx\/tx-mfl_mguard_smart2_firmwarefl_mguard_delta_tx\/tx_firmwarefl_mguard_pci4000fl_mguard_pci4000_vpn_firmwarefl_mguard_delta_tx\/tx_vpntc_mguard_rs4000_4g_vzw_vpnfl_mguard_rs4000_tx\/tx_vpntc_mguard_rs2000_4g_vzw_vpn_firmwarefl_mguard_rs4004_tx\/dtx_vpnfl_mguard_gt\/gtfl_mguard_4102_pciefl_mguard_core_txtc_mguard_rs4000_3g_vpnfl_mguard_rs4000_tx\/tx-p_firmwarefl_mguard_pci4000_vpnFL MGUARD 4102 PCIETC MGUARD RS4000 4G VPNFL MGUARD RS2000 TX/TX VPNTC MGUARD RS2000 4G ATT VPNFL MGUARD 4305FL MGUARD RS4004 TX/DTXTC MGUARD RS2000 3G VPNTC MGUARD RS4000 4G VZW VPNFL MGUARD DELTA TX/TXFL MGUARD PCIE4000FL MGUARD SMART2 VPNFL MGUARD CORE TXFL MGUARD RS4000 TX/TXFL MGUARD RS4000 TX/TX-PFL MGUARD RS2000 TX/TX-BFL MGUARD 2102FL MGUARD RS2005 TX VPNFL MGUARD PCIE4000 VPNFL MGUARD 4102 PCIFL MGUARD CENTERPORT VPN-1000FL MGUARD DELTA TX/TX VPNFL MGUARD RS4000 TX/TX VPNFL MGUARD RS4004 TX/DTX VPNFL MGUARD PCI4000 VPNFL MGUARD GT/GTFL MGUARD 2105TC MGUARD RS4000 3G VPNFL MGUARD CORE TX VPNTC MGUARD RS4000 4G ATT VPNFL MGUARD RS4000 TX/TX-MFL MGUARD 4302FL MGUARD SMART2FL MGUARD GT/GT VPNFL MGUARD PCI4000TC MGUARD RS2000 4G VPNTC MGUARD RS2000 4G VZW VPNfl_mguard_smart2_vpn_firmwaretc_mguard_rs4000_4g_vzw_vpn_firmwarefl_mguard_4305_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42739
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-12.76% / 93.74%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 00:00
Updated-14 Aug, 2024 | 15:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setAccessDeviceCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/ax5000r
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43778
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-8.8||HIGH
EPSS-1.33% / 79.14%
||
7 Day CHG~0.00%
Published-18 Sep, 2024 | 06:14
Updated-20 Sep, 2024 | 12:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings.

Action-Not Available
Vendor-TAKENAKA ENGINEERING CO., LTD.takenaka_engineering
Product-AHD04T-AAHD16T-AHDVR-400AHD08T-AHDVR-800NVR04T-ANVR16T-AHDVR-1600NVR08T-Aahd16t-a_firmwarehdvr-800_firmwarehdvr-1600_firmwarenvr16t-a_firmwarehdvr-400_firmwarenvr04t-a_firmwareahd08t-a_firmwarenvr08t-a_firmwareahd04t-a_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-38965
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-6.3||MEDIUM
EPSS-2.31% / 84.14%
||
7 Day CHG~0.00%
Published-17 Jan, 2022 | 17:15
Updated-17 Sep, 2024 | 01:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM FileNet Content Manager 5.5.4, 5.5.6, and 5.5.7 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 212346.

Action-Not Available
Vendor-IBM Corporation
Product-filenet_content_managerFileNet Content Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-37708
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-2.01% / 82.95%
||
7 Day CHG~0.00%
Published-16 Aug, 2021 | 19:15
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command injection in mail agent settings

Shopware is an open source eCommerce platform. Versions prior to 6.4.3.1 contain a command injection vulnerability in mail agent settings. Version 6.4.3.1 contains a patch. As workarounds for older versions of 6.1, 6.2, and 6.3, corresponding security measures are also available via a plugin.

Action-Not Available
Vendor-shopwareshopware
Product-shopwareplatform
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-42633
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-11.01% / 93.15%
||
7 Day CHG~0.00%
Published-19 Aug, 2024 | 00:00
Updated-20 Aug, 2024 | 16:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the do_upgrade_post function of the httpd binary in Linksys E1500 v1.0.06.001. As a result, an authenticated attacker can execute OS commands with root privileges.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-e1500_firmwaree1500n/ae1500_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-37531
Matching Score-4
Assigner-SAP SE
ShareView Details
Matching Score-4
Assigner-SAP SE
CVSS Score-9.9||CRITICAL
EPSS-4.22% / 88.30%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 11:15
Updated-04 Aug, 2024 | 01:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SAP NetWeaver Knowledge Management XML Forms versions - 7.10, 7.11, 7.30, 7.31, 7.40, 7.50, contains an XSLT vulnerability which allows a non-administrative authenticated attacker to craft a malicious XSL stylesheet file containing a script with OS-level commands, copy it into a location to be accessed by the system and then create a file which will trigger the XSLT engine to execute the script contained within the malicious XSL file. This can result in a full compromise of the confidentiality, integrity, and availability of the system.

Action-Not Available
Vendor-SAP SE
Product-netweaver_knowledge_management_xml_formsSAP NetWeaver Knowledge Management XML Forms
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-37158
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.33%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 23:11
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in OpenGamePanel OGP-Agent-Linux through 2021-08-14. An authenticated attacker could inject OS commands by starting a Counter-Strike server and using the map field to enter a Bash command.

Action-Not Available
Vendor-opengamepaneln/a
Product-opengamepaneln/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 15
  • 16
  • Next
Details not found