IBM Verify Gateway (IVG) 1.0.0 and 1.0.1 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 179478.
In Solstice Pod before 3.3.0 (or Open4.3), the screen key can be enumerated using brute-force attacks via the /lookin/info Solstice Open Control API because there are only 1.7 million possibilities.
In Solstice Pod before 3.3.0 (or Open4.3), the Administrator password can be enumerated using brute-force attacks via the /Config/service/initModel?password= Solstice Open Control API because there is no complexity requirement (e.g., it might be all digits or all lowercase letters).
JetKVM before 0.5.4 does not rate limit login requests, enabling brute-force attempts to guess credentials.
The GL-iNet Comet (GL-RM1) KVM web interface does not limit login requests, enabling brute-force attempts to guess credentials.
JHipster generator-jhipster before 2.23.0 allows a timing attack against validateToken due to a string comparison that stops at the first character that is different. Attackers can guess tokens by brute forcing one character at a time and observing the timing. This of course drastically reduces the search space to a linear amount of guesses based on the token length times the possible characters.
Binardat 10G08-0800GSM network switch firmware version V300SP10260209 and prior do not implement rate limiting or account lockout on failed login attempts, enabling brute-force attacks against user credentials.
Information disclosure in Logon Page in MV's mConnect application v02.001.00 allows an attacker to know valid users from the application's database via brute force.
Eaton Intelligent Power Protector (IPP) software allows repeated authentication attempts against the web interface login page due to insufficient rate‑limiting controls. This security issue has been fixed in the latest version of Eaton IPP which is available on the Eaton download centre.
The Web UI component of Mitel MiVoice 6800 and 6900 series SIP Phones with firmware before 5.1.0.SP5 could allow an unauthenticated attacker to expose sensitive information due to improper memory handling during failed login attempts.
IBM Security Guardium Big Data Intelligence 4.0 (SonarG) uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 161036.
A flaw was found in Moodle. A remote attacker could exploit a lack of proper rate limiting in the confirmation email service. This vulnerability allows attackers to more easily enumerate or guess user credentials, facilitating brute-force attacks against user accounts.
OPEXUS FOIAXpress Public Access Link (PAL) version v11.1.0 allows attackers to bypass account-lockout and CAPTCHA protections. Unauthenticated remote attackers can more easily brute force passwords.
Trilium Notes is an open-source, cross-platform hierarchical note taking application with focus on building large personal knowledge bases. In versions below 0.97.0, a brute-force protection bypass in the initial sync seed retrieval endpoint allows unauthenticated attackers to guess the login password without triggering rate limiting. Trilium is a single-user app without a username requirement, and brute-force protection bypass makes exploitation much more feasible. Multiple features provided by Trilium (e.g. MFA, share notes, custom request handler) indicate that Trilium can be exposed to the internet. This is fixed in version 0.97.0.
File Browser provides a file managing interface within a specified directory and it can be used to upload, delete, preview, rename and edit files. Prior to version 2.34.1, a missing password policy and brute-force protection makes the authentication process insecure. Attackers could mount a brute-force attack to retrieve the passwords of all accounts in a given instance. This issue has been patched in version 2.34.1.
Password guessing limits could be bypassed when using LDAP authentication.
Dell CloudBoost Virtual Appliance, versions 19.13.0.0 and prior, contains an Improper Restriction of Excessive Authentication Attempts vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access.
Vulnerability of brute-force attacks on the device authentication module.Successful exploitation of this vulnerability may affect service confidentiality.
IBM DevOps Plan 3.0.0 through 3.0.5 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials.
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not properly enforce restriction of excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.
Vulnerability of brute-force attacks on the device authentication module.Successful exploitation of this vulnerability may affect service confidentiality.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.
The Telnet service for Polycom ViewStation before 7.2.4 does not restrict the number of failed login attempts, which makes it easier for remote attackers to guess usernames and passwords via a brute force attack.
Improper restriction of excessive authentication attempts with two factor authentication methods in Checkmk 2.3 before 2.3.0p6 facilitates brute-forcing of second factor mechanisms.
Compaq/Microcom 6000 Access Integrator does not disconnect a client after a certain number of failed login attempts, which allows remote attackers to guess usernames or passwords via a brute force attack.
The SMB server's login mechanism does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
An issue has been discovered in GitLab CE/EE affecting all versions before 15.1.6, all versions starting from 15.2 before 15.2.4, all versions starting from 15.3 before 15.3.2. It may be possible for an attacker to guess a user's password by brute force by sending crafted requests to a specific endpoint, even if the victim user has 2FA enabled on their account.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) did not implement account lockout. Local account credentials may be extracted from the device via brute force guessing attacks.
Lack of protection against brute force attacks in M-Files Server before 23.12.13205.0 allows an attacker unlimited authentication attempts, potentially compromising targeted M-Files user accounts by guessing passwords.
OpenEMR 7.0.1 contains an authentication brute force vulnerability that allows attackers to bypass rate limiting protections by sending repeated login attempts to the main login endpoint. Attackers can submit POST requests with authUser and clearPass parameters to systematically test username and password combinations without account lockout restrictions.
By default, .ZED containers produced by PRIMX ZED! for Windows before Q.2020.3 (ANSSI qualification submission); ZED! for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before 2023.5; ZEDMAIL for Windows before 2023.5; and ZED! for Windows, Mac, Linux before 2023.5 include an encrypted version of sensitive user information, which could allow an unauthenticated attacker to obtain it via brute force.
IBM PowerSC 1.3, 2.0, and 2.1 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 275107.
LibreNMS is an auto-discovering PHP/MySQL/SNMP based network monitoring which includes support for a wide range of network hardware and operating systems. In affected versions the login method has no rate limit. An attacker may be able to leverage this vulnerability to gain access to user accounts. This issue has been addressed in version 23.11.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
IBM Engineering Lifecycle Optimization 7.0.2 and 7.0.3 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 268755.
Improper Restriction of Excessive Authentication Attempts in RDT400 in SICK APU allows an unprivileged remote attacker to guess the password via trial-and-error as the login attempts are not limited.
Nextcloud Server provides data storage for Nextcloud, an open source cloud platform. In Nextcloud Server starting with 25.0.0 and prior to 25.09 and 26.04; as well as Nextcloud Enterprise Server starting with 22.0.0 and prior to 22.2.10.14, 23.0.12.9, 24.0.12.5, 25.0.9, and 26.0.4; missing protection allows an attacker to brute force passwords on the WebDAV API. Nextcloud Server 25.0.9 and 26.0.4 and Nextcloud Enterprise Server 22.2.10.14, 23.0.12.9, 24.0.12.5, 25.0.9, and 26.0.4 contain patches for this issue. No known workarounds are available.
IBM Cloud Pak System 2.3.1.1, 2.3.2.0, and 2.3.3.7 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 260733.
SAP BusinessObjects Business Intelligence Platform - version 420, 430, allows an unauthorized attacker who had hijacked a user session, to be able to bypass the victim’s old password via brute force, due to unrestricted rate limit for password change functionality. Although the attack has no impact on integrity loss or system availability, this could lead to an attacker to completely takeover a victim’s account.
A lack of rate limiting in Elenos ETG150 FM transmitter v3.12 allows attackers to obtain user credentials via brute force and cause other unspecified impacts.
Improper Restriction of Excessive Authentication Attempts in the SICK ICR890-4 could allow a remote attacker to brute-force user credentials.
Weintek Weincloud v0.13.6 could allow an attacker to efficiently develop a brute force attack on credentials with authentication hints from error message responses.
Nextcloud Server is a data storage system for Nextcloud, a self-hosted productivity platform. When multiple requests are sent in parallel, all of them were executed even if the amount of faulty requests succeeded the limit by the time the response was sent to the client. This allowed someone to send as many requests the server could handle in parallel to bruteforce protected details instead of the configured limit, default 8. Nextcloud Server versions 25.0.7 and 26.0.2 and Nextcloud Enterprise Server versions 21.0.9.12, 22.2.10.12, 23.0.12.7, 24.0.12.2, 25.0.7 and 26.0.2 contain patches for this issue.