Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-04 Oct, 2023 | 18:13
Updated At-27 Feb, 2025 | 20:46
Rejected At-
Credits

A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:04 Oct, 2023 | 18:13
Updated At:27 Feb, 2025 | 20:46
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application.

Affected Products
Vendor
Schneider Electric SESchneider Electric
Product
EcoStruxure Power Monitoring Expert
Default Status
unaffected
Versions
Affected
  • All versions – prior to application of Hotfix-145271
Vendor
Schneider Electric SESchneider Electric
Product
EcoStruxure Power Operation (EPO) with Advanced Reports
Default Status
unaffected
Versions
Affected
  • All versions – prior to application of Hotfix-145271
Vendor
Schneider Electric SESchneider Electric
Product
EcoStruxure Power SCADA Operation with Advanced Reports
Default Status
unaffected
Versions
Affected
  • All versions – prior to application of Hotfix-145271
Problem Types
TypeCWE IDDescription
CWECWE-502CWE-502 Deserialization of Untrusted Data
Type: CWE
CWE ID: CWE-502
Description: CWE-502 Deserialization of Untrusted Data
Metrics
VersionBase scoreBase severityVector
3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf
N/A
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:04 Oct, 2023 | 19:15
Updated At:01 Feb, 2024 | 00:49

A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Secondary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Schneider Electric SE
schneider-electric
>>ecostruxure_power_monitoring_expert>>*
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_power_operation_with_advanced_reports>>*
cpe:2.3:a:schneider-electric:ecostruxure_power_operation_with_advanced_reports:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_power_scada_operation_with_advanced_reports>>*
cpe:2.3:a:schneider-electric:ecostruxure_power_scada_operation_with_advanced_reports:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-502Primarycybersecurity@se.com
CWE ID: CWE-502
Type: Primary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdfcybersecurity@se.com
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1073Records found

CVE-2017-6034
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.14% / 34.65%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-04 Jun, 2026 | 22:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay

An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.

Action-Not Available
Vendor-Schneider Electric SE
Product-modbus_firmwaremodbusModicon Modbus Protocol
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2017-6028
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.32% / 55.37%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m241modicon_m251_firmwaremodicon_m241_firmwaremodicon_m251Schneider Electric Modicon PLCs
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-30234
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.4||CRITICAL
EPSS-0.37% / 59.06%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-16 Sep, 2024 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2012-0931
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.15% / 88.95%
||
7 Day CHG~0.00%
Published-28 Jan, 2012 | 01:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_quantum_plcn/a
CWE ID-CWE-287
Improper Authentication
CVE-2022-26507
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.70% / 91.48%
||
7 Day CHG~0.00%
Published-14 Apr, 2022 | 12:04
Updated-03 Aug, 2024 | 05:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

Action-Not Available
Vendor-attn/a
Product-ecostruxure_process_expertecostruxure_control_expertremoteconnectxmillscadapack_470scadapack_570scadapack_574scadapack_575scadapack_474n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-24310
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.98% / 84.00%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2022-24311
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.70% / 88.26%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-2329
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.83% / 88.44%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2022-22731
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.56% / 68.91%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-22805
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-8.20% / 92.42%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 19:30
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Action-Not Available
Vendor-
Product-scl_series_1036_upssmc_series_1018_ups_firmwaresmtl_series_1026_upsscl_series_1029_ups_firmwaresmt_series_1015_upssmtl_series_1026_ups_firmwarescl_series_1030_ups_firmwaresmt_series_1015_ups_firmwaresmx_series_1031_ups_firmwaresmx_series_1031_upsscl_series_1037_ups_firmwarescl_series_1037_upsscl_series_1036_ups_firmwaresmc_series_1018_upsscl_series_1030_upsscl_series_1029_upsSmartConnect
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-24324
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.43% / 85.54%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-22810
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.30% / 54.00%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)

Action-Not Available
Vendor-n/a
Product-fellerlynkwiser_for_knxspacelynkwiser_for_knx_firmwarefellerlynk_firmwarespacelynk_firmwarespaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2022-22806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.23% / 45.67%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 19:30
Updated-03 Aug, 2024 | 03:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Action-Not Available
Vendor-
Product-scl_series_1036_upssmc_series_1018_ups_firmwaresmtl_series_1026_upsscl_series_1029_ups_firmwaresmt_series_1015_upssmtl_series_1026_ups_firmwarescl_series_1030_ups_firmwaresmt_series_1015_ups_firmwaresmx_series_1031_ups_firmwaresmx_series_1031_upsscl_series_1037_ups_firmwarescl_series_1037_upsscl_series_1036_ups_firmwaresmc_series_1018_upsscl_series_1030_upsscl_series_1029_upsSmartConnect
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2022-0223
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.57% / 69.02%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-11737
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.3||CRITICAL
EPSS-0.46% / 64.73%
||
7 Day CHG~0.00%
Published-11 Dec, 2024 | 09:36
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could lead to a denial of service and a loss of confidentiality, integrity of the controller when an unauthenticated crafted Modbus packet is sent to the device.

Action-Not Available
Vendor-
Product-Modicon Controllers M241 / M251Modicon Controllers M258 / LMC058
CWE ID-CWE-20
Improper Input Validation
CVE-2024-10575
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-10||CRITICAL
EPSS-0.40% / 61.32%
||
7 Day CHG~0.00%
Published-13 Nov, 2024 | 04:35
Updated-19 Nov, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on the network and potentially impacting connected devices.

Action-Not Available
Vendor-
Product-ecostruxure_it_gatewayEcoStruxure IT Gatewayecostruxure_it_gateway
CWE ID-CWE-862
Missing Authorization
CVE-2023-5399
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-25.06% / 96.31%
||
7 Day CHG~0.00%
Published-04 Oct, 2023 | 18:07
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause tampering of files on the personal computer running C-Bus when using the File Command.

Action-Not Available
Vendor-Schneider Electric SE
Product-spacelogic_c-bus_toolkitC-Bus Toolkit
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-5402
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 51.39%
||
7 Day CHG~0.00%
Published-04 Oct, 2023 | 17:59
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-269: Improper Privilege Management vulnerability exists that could cause a remote code execution when the transfer command is used over the network.

Action-Not Available
Vendor-Schneider Electric SE
Product-c-bus_toolkitC-Bus Toolkit
CWE ID-CWE-269
Improper Privilege Management
CVE-2018-7231
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.14% / 78.91%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-16 Sep, 2024 | 19:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7233
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.14% / 78.91%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 01:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22707
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-91.56% / 99.69%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2021-22731
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.88% / 75.89%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker.

Action-Not Available
Vendor-n/a
Product-mcsesm083f23f0hmcsesp083f23g0t_firmwaremcsesm083f23f0_firmwaremcsesp083f23g0tmcsesm063f2cu0mcsesm063f2cs0_firmwaremcsesm103f2cu0mcsesm123f2lg0mcsesp083f23g0_firmwaremcsesm103f2cu0hmcsesm053f1cu0_firmwaremcsesm103f2cs0hmcsesm093f1cu0_firmwaremcsesm093f1cu0mcsesm043f23f0_firmwaremcsesm093f1cs0_firmwaremcsesm053f1cu0mcsesm043f23f0mcsesm103f2cs0_firmwaremcsesm103f2cs0h_firmwaremcsesm083f23f0h_firmwaremcsesm083f23f0mcsesm063f2cu0_firmwaremcsesm123f2lg0_firmwaremcsesm053f1cs0_firmwaremcsesp083f23g0mcsesm063f2cs0mcsesm103f2cu0_firmwaremcsesm103f2cu0h_firmwaremcsesm093f1cs0mcsesm103f2cs0mcsesm053f1cs0Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2021-22730
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.35% / 57.73%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:44
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2017-9629
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-19.70% / 95.59%
||
7 Day CHG~0.00%
Published-07 Jul, 2017 | 17:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_archestra_loggerSchneider Electric Wonderware ArchestrA Logger
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-6407
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 60.74%
||
7 Day CHG~0.00%
Published-11 Jul, 2024 | 09:07
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Action-Not Available
Vendor-
Product-whc-5918awhc-5918a_firmwareWiser Home Controller WHC-5918A
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2025-1960
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.21% / 44.18%
||
7 Day CHG~0.00%
Published-12 Mar, 2025 | 15:33
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.

Action-Not Available
Vendor-Schneider Electric SE
Product-WebHMI – Deployed with EcoStruxure Power Automation System
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2021-30064
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.06% / 18.44%
||
7 Day CHG~0.00%
Published-03 Apr, 2022 | 21:56
Updated-03 Aug, 2024 | 22:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).

Action-Not Available
Vendor-beldenn/a
Product-tofino_argon_fa-tsa-220-mm\/txeagle_20_tofino_943_987-504-mm\/txtofino_argon_fa-tsa-220-tx\/txtcsefea23f3f21_firmwareeagle_20_tofino_943_987-502_-tx\/mm_firmwareeagle_20_tofino_943_987-501-tx\/txtofino_argon_fa-tsa-220-mm\/tx_firmwaretofino_argon_fa-tsa-100-tx\/txtofino_xenon_security_appliance_firmwareeagle_20_tofino_943_987-501-tx\/tx_firmwaretcsefea23f3f21eagle_20_tofino_943_987-504-mm\/tx_firmwaretofino_argon_fa-tsa-220-tx\/mm_firmwaretofino_xenon_security_appliancetofino_argon_fa-tsa-100-tx\/tx_firmwareeagle_20_tofino_943_987-502_-tx\/mmtcsefea23f3f22_firmwaretofino_argon_fa-tsa-220-tx\/tx_firmwareeagle_20_tofino_943_987-505-mm\/mmtofino_argon_fa-tsa-220-tx\/mmtcsefea23f3f22eagle_20_tofino_943_987-505-mm\/mm_firmwaretofino_argon_fa-tsa-220-mm\/mmtcsefea23f3f20tofino_argon_fa-tsa-220-mm\/mm_firmwaretcsefea23f3f20_firmwaren/a
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2024-37036
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.09% / 25.24%
||
7 Day CHG~0.00%
Published-12 Jun, 2024 | 16:48
Updated-14 Aug, 2024 | 14:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-787: Out-of-bounds Write vulnerability exists that could result in an authentication bypass when sending a malformed POST request and particular configuration parameters are set.

Action-Not Available
Vendor-
Product-sage_4400sage_1410sage_3030_magnumsage_2400sage_rtu_firmwaresage_1450sage_1430Sage 4400Sage 1450Sage 1410Sage 3030 MagnumSage 1430Sage 2400sage_4400_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8884
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.18% / 39.82%
||
7 Day CHG~0.00%
Published-08 Oct, 2024 | 10:32
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause exposure of credentials when attacker has access to application on network over http

Action-Not Available
Vendor-
Product-System Monitor application in Harmony Industrial PC HMIBMO/HMIBMI/HMIPSO/HMIBMP/HMIBMU/HMIPSP/HMIPEP seriesSystem Monitor application in Pro-face Industrial PC PS5000 seriessystem_monitor_application_in_harmony_industrial_pc_hmibmo_hmibmi_hmipso_hmibmp_hmibmu_hmipsp_hmipep_series
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22727
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.60% / 70.04%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:43
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized access to the charging station web server

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-331
Insufficient Entropy
CVE-2021-22794
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-3.73% / 88.30%
||
7 Day CHG~0.00%
Published-28 Mar, 2022 | 16:25
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22772
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.28% / 52.19%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when authentication is bypassed.

Action-Not Available
Vendor-n/a
Product-t200et200i_firmwaret200it200pt200e_firmwaret200p_firmwareEasergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2020-7521
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.73% / 73.26%
||
7 Day CHG~0.00%
Published-31 Aug, 2020 | 16:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.

Action-Not Available
Vendor-n/a
Product-apc_easy_ups_online_softwareSFAPV9601 - APC Easy UPS On-Line Software V2.0 and earlier
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22763
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 50.59%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 14:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_pm5562powerlogic_pm8eccpowerlogic_pm5560powerlogic_pm5560_firmwarepowerlogic_pm5562_firmwarepowerlogic_pm5563_firmwarepowerlogic_pm5563powerlogic_pm8ecc_firmwarepowerlogic_pm5561_firmwarepowerlogic_pm5561PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation)
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2021-22801
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.84% / 75.30%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially crafted event actions. Affected Product: ConneXium Network Manager Software (All Versions)

Action-Not Available
Vendor-n/a
Product-connexium_network_managerConneXium Network Manager Software (All Versions)
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-22765
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.61% / 70.24%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_egx300_firmwarepowerlogic_egx100_firmwarepowerlogic_egx100powerlogic_egx300PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22803
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.03% / 84.21%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2021-22729
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.35% / 57.73%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:44
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-259
Use of Hard-coded Password
CVE-2021-22738
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.18% / 40.14%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access when credentials are discovered after a brute force attack.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-327
Use of a Broken or Risky Cryptographic Algorithm
CVE-2021-22802
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.47% / 85.64%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-22820
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.57% / 69.21%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evp2pe_firmwareevlink_parking_evf2_firmwareevlink_parking_evw2evlink_parking_evp2peevlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_city_evc1s7p4n/a
CWE ID-CWE-613
Insufficient Session Expiration
CVE-2021-22714
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.27% / 85.05%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:13
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.

Action-Not Available
Vendor-n/a
Product-powerlogic_ion9000_firmwarepowerlogic_pm8000_firmwarepowerlogic_pm8000powerlogic_ion9000powerlogic_ion7400_firmwarepowerlogic_ion7400PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22795
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-3.19% / 87.31%
||
7 Day CHG~0.00%
Published-28 Mar, 2022 | 16:25
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-22767
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.79% / 74.37%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_egx300_firmwarepowerlogic_egx100_firmwarepowerlogic_egx100powerlogic_egx300PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22768
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.79% / 74.37%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_egx300_firmwarepowerlogic_egx100_firmwarepowerlogic_egx100powerlogic_egx300PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22737
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.30% / 54.18%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 00:00
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.

Action-Not Available
Vendor-n/a
Product-homelynkspacelynk_firmwarehomelynk_firmwarespacelynkhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2023-29412
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.54% / 85.83%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:50
Updated-05 Feb, 2025 | 21:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-29411
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-7.71% / 92.14%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:49
Updated-05 Feb, 2025 | 21:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-28004
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.28% / 80.08%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 21:16
Updated-02 Aug, 2024 | 12:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution.

Action-Not Available
Vendor-
Product-powerlogic_hdpm6000_firmwarepowerlogic_hdpm6000PowerLogic HDPM6000
CWE ID-CWE-129
Improper Validation of Array Index
CVE-2022-45788
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.40% / 60.92%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-29 May, 2026 | 14:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)

Action-Not Available
Vendor-Schneider Electric SE
Product-modicon_m340_bmxp342030_firmwaremodicon_premium_tsxp57_454mmodicon_m340_bmxp3420302h_firmwaremodicon_premium_tsxp57_2834m_firmwaremodicon_premium_tsxp57_6634m_firmwaremodicon_m340_bmxp342020h_firmwaremodicon_m580_bmep583040_firmwaremodicon_m580_bmeh582040smodicon_quantum_140cpu65160_firmwaremodicon_m340_bmxp3420302_firmwaremodicon_m340_bmxp342010modicon_m580_bmeh584040smodicon_m580_bmep582020h_firmwaremodicon_m580_bmep584040s_firmwaremodicon_m580_bmep584040modicon_m340_bmxp342010_firmwaremodicon_m340_bmxp342020_firmwaremodicon_mc80_bmkc8020310_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep582040h_firmwaremodicon_premium_tsxp57_454m_firmwaremodicon_quantum_140cpu65150modicon_m580_bmep584040_firmwaremodicon_momentum_171cbu78090_firmwaremodicon_m580_bmep584040smodicon_m580_bmeh582040cmodicon_m580_bmep583040ecostruxure_control_expertmodicon_m580_bmep582040modicon_m580_bmep585040modicon_premium_tsxp57_4634mmodicon_m580_bmep584020_firmwaremodicon_m580_bmeh584040modicon_m580_bmep585040c_firmwaremodicon_premium_tsxp57_2634m_firmwaremodicon_m580_bmeh584040_firmwaremodicon_momentum_171cbu78090modicon_premium_tsxp57_5634mmodicon_m580_bmep581020h_firmwaremodicon_m580_bmep584020modicon_mc80_bmkc8020301modicon_m580_bmeh584040s_firmwaremodicon_momentum_171cbu98090_firmwaremodicon_m580_bmep582040smodicon_premium_tsxp57_1634m_firmwaremodicon_m340_bmxp342020modicon_m340_bmxp342030hmodicon_m340_bmxp342020hmodicon_m580_bmeh586040cmodicon_m580_bmep582020_firmwaremodicon_momentum_171cbu98091modicon_m340_bmxp342000_firmwaremodicon_m580_bmep581020hmodicon_m580_bmeh586040_firmwaremodicon_m580_bmeh584040cmodicon_m340_bmxp342030modicon_m580_bmeh586040c_firmwaremodicon_m580_bmep586040_firmwaremodicon_m580_bmeh582040_firmwaremodicon_quantum_140cpu65150c_firmwaremodicon_m580_bmep582040_firmwaremodicon_m580_bmeh582040modicon_quantum_140cpu65160c_firmwaremodicon_mc80_bmkc8030311modicon_quantum_140cpu65160modicon_momentum_171cbu98090modicon_premium_tsxp57_1634mmodicon_m580_bmeh582040c_firmwaremodicon_m580_bmep583020modicon_m580_bmeh586040s_firmwaremodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_premium_tsxp57_2634mmodicon_m340_bmxp342000modicon_m580_bmeh586040modicon_m580_bmep583020_firmwaremodicon_premium_tsxp57_5634m_firmwaremodicon_premium_tsxp57_554m_firmwaremodicon_m340_bmxp341000modicon_mc80_bmkc8020310modicon_m580_bmep582020modicon_quantum_140cpu65160cmodicon_m580_bmeh584040c_firmwaremodicon_quantum_140cpu65150_firmwaremodicon_momentum_171cbu98091_firmwaremodicon_quantum_140cpu65150cmodicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_mc80_bmkc8030311_firmwaremodicon_m580_bmep582040hmodicon_m340_bmxp3420302modicon_premium_tsxp57_554mmodicon_m580_bmep582040s_firmwaremodicon_premium_tsxp57_2834mmodicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwaremodicon_mc80_bmkc8020301_firmwareecostruxure_process_expertmodicon_m580_bmep581020modicon_m580_bmep586040cmodicon_premium_tsxp57_4634m_firmwaremodicon_m340_bmxp342030h_firmwaremodicon_m580_bmep582020hmodicon_m580_bmep586040c_firmwaremodicon_m340_bmxp3420102modicon_m580_bmeh582040s_firmwaremodicon_premium_tsxp57_6634mLegacy Modicon Quantum (140CPU65*) and Premium CPUs (TSXP57*)Modicon M580 CPU (part numbers BMEP* and BMEH*) Modicon M340 CPU (part numbers BMXP34*)Modicon MC80 (BMKC80)EcoStruxure Control Expert Modicon Momentum Unity M1E Processor (171CBU*)Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)EcoStruxure Process Expert
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 21
  • 22
  • Next
Details not found