systeminformation is a System Information Library for Node.JS. Versions 5.0.0 through 5.21.6 have a SSID Command Injection Vulnerability. The problem was fixed with a parameter check in version 5.21.7. As a workaround, check or sanitize parameter strings that are passed to `wifiConnections()`, `wifiNetworks()` (string only).
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges.
A weakness has been identified in D-Link DIR-806A 100CNb11. Affected is the function ssdpcgi_main of the component SSDP Request Handler. This manipulation causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited. This vulnerability only affects products that are no longer supported by the maintainer.
D-LINK DWL-6610 FW_v_4.3.0.8B003C was discovered to contain a command injection vulnerability in the function sub_2EF50. This vulnerability allows attackers to execute arbitrary commands via the manual-time-string parameter.
A vulnerability classified as critical was found in TOTOLINK A6000R 1.0.1-B20201211.2000. Affected by this vulnerability is the function apcli_cancel_wps of the file /usr/lib/lua/luci/controller/mtkwifi.lua. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
D-LINK DWL-6610 FW_v_4.3.0.8B003C was discovered to contain a command injection vulnerability in the function pcap_download_handler. This vulnerability allows attackers to execute arbitrary commands via the update.device.packet-capture.tftp-file-name parameter.
Wavlink WL-WN575A3 RPT75A3.V4300.201217 was discovered to contain a command injection vulnerability via the function obtw. This vulnerability allows attackers to execute arbitrary commands via a crafted POST request.
D-LINK DWL-6610 FW_v_4.3.0.8B003C was discovered to contain a command injection vulnerability in the function web_cert_download_handler. This vulnerability allows attackers to execute arbitrary commands via the certDownload parameter.
A vulnerability was detected in TRENDnet TEW-713RE 1.02. The impacted element is an unknown function of the file /goformX/formFSrvX. The manipulation of the argument SZCMD results in os command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. The vendor confirms: "The product in question TEW-731RE for CVE-2025-15471 has been discontinued and end of life since October 23, 2020. We no longer provide support for this product, so we are not able to confirm the vulnerabilities. We will make an announcement on the website product support page and notify customers who registered their products with us." This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230722 and classified as critical. This issue affects some unknown processing of the file importhtml.php. The manipulation of the argument sql leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-235967. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Command Execution vulnerability in China Mobile Communications China Mobile Intelligent Home Gateway v.HG6543C4 allows a remote attacker to execute arbitrary code via the shortcut_telnet.cg component.
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in LB-LINK AC1900 Router 1.0.2 and classified as critical. Affected by this issue is the function websGetVar of the file /goform/set_blacklist. The manipulation of the argument mac/enable leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formRoute of the component Web-based Configuration Interface. The manipulation of the argument strIp/strMask/strGateway results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
WAVLINK WN572HP3, WN533A8, WN530H4, WN535G3, WN531P3 nas.cgi has no filtering on parameters: User1Passwd and User1, which leads to command injection in page /nas_disk.shtml.
A command injection vulnerability on AX53 v1 occurs in mscd debug functionality due to insufficient input handling, allowing log redirection to arbitrary files and concatenation of unvalidated file content into shell commands, enabling authenticated attackers to inject and execute arbitrary commands. Successful exploitation may allow execution of malicious commands and ultimately full control of the device.
A command injection vulnerability exists in MLflow's model serving container initialization code, specifically in the `_install_model_dependencies_to_env()` function. When deploying a model with `env_manager=LOCAL`, MLflow reads dependency specifications from the model artifact's `python_env.yaml` file and directly interpolates them into a shell command without sanitization. This allows an attacker to supply a malicious model artifact and achieve arbitrary command execution on systems that deploy the model. The vulnerability affects versions 3.8.0 and is fixed in version 3.8.2.
A privilege escalation vulnerability exists in the /bin/login functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted command line argument can lead to a limited-shell escape and elevated capabilities. An attacker can authenticate with hard-coded credentials and execute unblocked default busybox functionality to trigger this vulnerability.
Improper input validation in Citrix XenMobile Server 10.12 before RP3, Citrix XenMobile Server 10.11 before RP6, Citrix XenMobile Server 10.10 RP6 and Citrix XenMobile Server before 10.9 RP5 allows SQL Injection.
NETSCOUT nGeniusPULSE 3.8 has a Command Injection Vulnerability.
Netgear R7100LG 1.0.0.78 was discovered to contain a command injection vulnerability via the password parameter at usb_remote_invite.cgi.
A vulnerability, which was classified as critical, was found in LB-LINK AC1900 Router 1.0.2. Affected is the function websGetVar of the file /goform/set_manpwd. The manipulation of the argument routepwd leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Dango-Translator v4.5.5 was discovered to contain a remote command execution (RCE) vulnerability via the component app/config/cloud_config.json.
A Command Injection vulnerability has been identified in the MiVoice Office 400 SMB Controller through 1.2.5.23 which could allow a malicious actor to execute arbitrary commands within the context of the system.
COMFAST CF-XR11 V2.7.2 has a command injection vulnerability detected at function sub_4143F0. Attackers can send POST request messages to /usr/bin/webmgnt and inject commands into parameter timestr.
A command injection vulnerability in the component diag_backup.php of OPNsense Community Edition before 23.7 and Business Edition before 23.4.2 allows attackers to execute arbitrary commands via a crafted backup configuration file.
matrix-appservice-irc is a Node.js IRC bridge for Matrix. Prior to version 1.0.1, it is possible to craft a command with newlines which would not be properly parsed. This would mean you could pass a string of commands as a channel name, which would then be run by the IRC bridge bot. Versions 1.0.1 and above are patched. There are no robust workarounds to the bug. One may disable dynamic channels in the config to disable the most common execution method but others may exist.
We have recently released new version of AirMax AirOS firmware v6.3.0 for TI, XW and XM boards that fixes vulnerabilities found on AirMax AirOS v6.2.0 and prior TI, XW and XM boards, according to the description below:There are certain end-points containing functionalities that are vulnerable to command injection. It is possible to craft an input string that passes the filter check but still contains commands, resulting in remote code execution.Mitigation:Update to the latest AirMax AirOS firmware version available at the AirMax download page.
django-sspanel v2022.2.2 was discovered to contain a remote command execution (RCE) vulnerability via the component sspanel/admin_view.py -> GoodsCreateView._post.
TOTOLINK LR350 V9.3.5u.6369_B20220309 was discovered to contain a command injection vulnerability via the FileName parameter in the setUploadSetting function.
A vulnerability was determined in TOTOLINK X5000R 9.1.0cu.2089_B20211224. Affected by this issue is the function snprintf of the file /cgi-bin/cstecgi.cgi?action=exportOvpn&type=user. This manipulation of the argument User causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.
A remote command execution (RCE) vulnerability in NextGen Mirth Connect v4.3.0 allows attackers to execute arbitrary commands on the hosting server.
WAYOS FBM-291W 19.09.11V was discovered to contain a command injection vulnerability via the component /upgrade_filter.asp.
Command injection vulnerability in ELECOM and LOGITEC wireless LAN routers allows a remote unauthenticated attacker to execute an arbitrary command by sending a specially crafted request to a certain port of the web management page. Affected products and versions are as follows: WRC-1167GHBK3-A v1.24 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1900GHBK-A all versions, and LAN-W301NR all versions.
SpotCam Co., Ltd. SpotCam Sense’s hidden Telnet function has a vulnerability of OS command injection. An remote unauthenticated attacker can exploit this vulnerability to execute command injection attack to perform arbitrary system commands or disrupt service.
An issue in BL-AC2100 V1.0.4 and before allows a remote attacker to execute arbitrary code via the enable parameter passed to /goform/set_hidessid_cfg is not handled properly.
A vulnerability was identified in Shiguangwu sgwbox N3 2.0.25. This impacts an unknown function of the file /usr/sbin/http_eshell_server of the component NETREBOOT Interface. Such manipulation leads to command injection. The attack can be launched remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injection.This issue affects PM43 versions prior to P10.19.050004. Update to the latest available firmware version of the respective printers to version MR19.5 (e.g. P10.19.050006).
Heights Telecom ERO1xS-Pro Dual-Band FW version BZ_ERO1XP.025.
A command injection vulnerability in the DHCP Client function of all UniFi Access Points and Switches, excluding the Switch Flex Mini, could allow a Remote Code Execution (RCE). Affected Products: All UniFi Access Points (Version 6.5.53 and earlier) All UniFi Switches (Version 6.5.32 and earlier) -USW Flex Mini excluded. Mitigation: Update UniFi Access Points to Version 6.5.62 or later. Update UniFi Switches to Version 6.5.59 or later.
TOTOLINK LR350 V9.3.5u.6369_B20220309 was discovered to contain a command injection vulnerability via the hostname parameter in the setOpModeCfg function.
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
TOTOLINK LR350 V9.3.5u.6369_B20220309 was discovered to contain a command injection vulnerability via the FileName parameter in the UploadFirmwareFile function.
TOTOLINK LR350 V9.3.5u.6369_B20220309 was discovered to contain a command injection vulnerability via the ussd parameter in the setUssd function.
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.15), Teamcenter V13.0 (All versions < V13.0.0.10), Teamcenter V13.1 (All versions < V13.1.0.10), Teamcenter V13.2 (All versions < V13.2.0.9), Teamcenter V13.3 (All versions < V13.3.0.5), Teamcenter V14.0 (All versions < V14.0.0.2). File Server Cache service in Teamcenter consist of a functionality that is vulnerable to command injection. This could potentially allow an attacker to perform remote code execution.
A vulnerability was determined in Shiguangwu sgwbox N3 2.0.25. This affects an unknown function of the component SHARESERVER Feature. This manipulation of the argument params causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the POST parameters passed in this request (to test if email credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The library "libmailutils.so" is the one that has the vulnerable function "sub_1FC4" that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows an ARM little endian format. The function sub_1FC4 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "receiver1" is extracted in function "sub_15AC" which is then passed to the vulnerable system API call. The vulnerable library function is accessed in "cgibox" binary at address 0x0008F598 which calls the "mailLoginTest" function in "libmailutils.so" binary as shown below which results in the vulnerable POST parameter being passed to the library which results in the command injection issue.
A flaw has been found in Edimax BR-6478AC V3 1.0.15. The affected element is the function sub_44CCE4 of the file /boafrm/formSysCmd. This manipulation of the argument sysCmd causes os command injection. The attack may be initiated remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue discovered in sub_4117F8 function in TOTOLINK X6000R V9.4.0cu.852_B20230719 allows attackers to run arbitrary commands via the 'lang' parameter.