In Phoenix Contact FL SWITCH SMCS series products in multiple versions if an attacker sends a hand-crafted TCP-Packet with the Urgent-Flag set and the Urgent-Pointer set to 0, the network stack will crash. The device needs to be rebooted afterwards.
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
An unauthenticated remote attacker can cause a Denial of Service by sending a large number of requests to the http service on port 80.
Uncontrolled Resource Consumption can be exploited to cause the Phoenix Contact HMIs BTP 2043W, BTP 2070W and BTP 2102W in all versions to become unresponsive and not accurately update the display content (Denial of Service).
Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests.
In Phoenix Contact FL COMSERVER UNI in versions < 2.40 a invalid Modbus exception response can lead to a temporary denial of service.
Phoenix Contact Classic Line Controllers ILC1x0 and ILC1x1 in all versions/variants are affected by a Denial-of-Service vulnerability. The communication protocols and device access do not feature authentication measures. Remote attackers can use specially crafted IP packets to cause a denial of service on the PLC's network communication module. A successful attack stops all network communication. To restore the network connectivity the device needs to be restarted. The automation task is not affected.
A low-privileged local attacker can exploit improper permissions on nssm.exe to escalate their privileges and gain administrative access.
Phoenix Contact ProConOs and MultiProg do not require authentication, which allows remote attackers to execute arbitrary commands via protocol-compliant traffic.
An unauthenticated adjacent attacker can modify configuration by sending specific requests to an API-endpoint resulting in read and write access due to missing authentication.
Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14.
An unprotected logging route may allow an attacker to write endless log statements into the database without space limits or authentication. This results in consuming the entire available hard-disk space on the Ignition 8 Gateway (versions prior to 8.0.10), causing a denial-of-service condition.
A vulnerability was found in SimStudioAI sim up to 37786d371e17d35e0764e1b5cd519d873d90d97b. It has been declared as critical. Affected by this vulnerability is the function POST of the file apps/sim/app/api/files/upload/route.ts of the component Session Handler. The manipulation of the argument Request leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition.
Hermes Agent before 0.16.0 contains a DNS rebinding vulnerability in WebSocket endpoints that allows remote attackers to bypass Host and Origin validation. FastAPI HTTP middleware does not execute for WebSocket upgrade requests on /api/pty, /api/ws, /api/pub, and /api/events endpoints, enabling attackers to exploit DNS rebinding and inject malicious commands or read terminal output.
Core FTP 2.0 build 653 contains a denial of service vulnerability in the PBSZ command that allows unauthenticated attackers to crash the service by sending a malformed command with an oversized buffer. Attackers can send a PBSZ command with a payload exceeding 211 bytes to trigger an access violation and crash the FTP server process.
D-Link D-View shutdown_coreserver Missing Authentication Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of D-Link D-View. Authentication is not required to exploit this vulnerability. The specific flaw exists within the shutdown_coreserver action. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-19572.
Capgo before 12.128.2 contains a denial of service vulnerability allowing attackers to register accounts using arbitrary email addresses without verification, then initiate deletion to lock emails in pending deletion state. Attackers can permanently lock legitimate users out of the platform for 30 days by exploiting unverified email ownership in account lifecycle operations.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 7061/tcp. This vulnerability is independent from CVE-2019-18310. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
An issue was discovered on Belkin Wemo Switch 28B WW_2.00.11057.PVT-OWRT-SNS devices. They allow remote attackers to cause a denial of service (persistent rules-processing outage) via a crafted ruleDbBody element in a StoreRules request to the upnp/control/rules1 URI, because database corruption occurs.
The Web Management of TP-Link TP-SG105E V4 1.0.0 Build 20181120 devices allows an unauthenticated attacker to reboot the device via a reboot.cgi request.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a sequence of Modbus RTU over TCP messages to port 503 using the Write Single Register function code (6). The attack sequence begins with a message to register 58112 with a value of 1000, indicating that a configuration change will follow. Next, a message is sent to register 29440 with a value corresponding to the new Modbus address to be configured. Finally, a message to register 57856 with a value of 161 commits the configuration change. After this configuration change, the device will be in a denial-of-service state.
Vulnerability in the Oracle Financial Services Analytical Applications Infrastructure product of Oracle Financial Services Applications (component: System Configuration). Supported versions that are affected are 8.0.7.9, 8.0.8.7 and 8.1.2.5. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Financial Services Analytical Applications Infrastructure. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of Oracle Financial Services Analytical Applications Infrastructure. CVSS 3.1 Base Score 7.5 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
free5GC is an open-source implementation of the 5G core network. Prior to 4.2.2, free5GC's SMF mounts the UPI management route group without inbound OAuth2 middleware. The POST /upi/v1/upNodesLinks create-or-update handler accepts attacker-controlled JSON and passes it directly into UpNodesFromConfiguration(), which calls logger.InitLog.Fatalf(...) on several validation failures. One confirmed path is the UE-IP-pool overlap check: a single unauthenticated POST that adds a new UPF whose pool overlaps an existing UPF terminates the entire SMF process (docker ps shows Exited (1)), not just the goroutine. This vulnerability is fixed in 4.2.2.
A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) Supervisor, Cisco UCS Director, and Cisco UCS Director Express for Big Data could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition. The vulnerability is due to a missing authentication check in an API call. An attacker who can send a request to an affected system could cause all currently authenticated users to be logged off. Repeated exploitation could cause the inability to maintain a session in the web-based management portal.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 14.1.1.0.0 and 14.1.2.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP/2 to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of Oracle WebLogic Server. CVSS 3.1 Base Score 7.5 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
The Chaos Controller Manager in Chaos Mesh exposes a GraphQL debugging server without authentication to the entire Kubernetes cluster, which provides an API to kill arbitrary processes in any Kubernetes pod, leading to cluster-wide denial of service.
An incorrect API discovered in Signify Wiz Connected 1.9.1 allows attackers to remotely launch a DoS on Wiz devices only requiring the MAC address.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a single Modbus TCP message to port 503 using the Write Single Register function code (6) to write the value 1 to register 4352. This action changes the Modbus address to 15. After this message is sent, the device will be in a denial-of-service state.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a sequence of Modbus TCP messages to port 502 using the Write Single Register function code (6). The attack sequence begins with a message to register 58112 with a value of 1000, indicating that a configuration change will follow. Next, a message is sent to register 29440 with a value corresponding to the new Modbus address to be configured. Finally, a message to register 57856 with a value of 161 commits the configuration change. After this configuration change, the device will be in a denial-of-service state.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP USB Function functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted network packet can lead to a denial of service. An attacker can send an unauthenticated packet to trigger this vulnerability.This vulnerability is specific to the malicious message sent via Modbus TCP over port 502.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP USB Function functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted network packet can lead to a denial of service. An attacker can send an unauthenticated packet to trigger this vulnerability.This vulnerability is specific to the malicious message sent via Modbus RTU over TCP on port 503.
WWBN AVideo is an open source video platform. In versions 26.0 and prior, the AVideo on_publish_done.php endpoint in the Live plugin allows unauthenticated users to terminate any active live stream. The endpoint processes RTMP callback events to mark streams as finished in the database, but performs no authentication or authorization checks before doing so. An attacker can enumerate active stream keys from the unauthenticated stats.json.php endpoint, then send crafted POST requests to on_publish_done.php to terminate any live broadcast. This enables denial-of-service against all live streaming functionality on the platform. At time of publication, there are no publicly available patches.
Missing Authentication for Critical Function in SICK Flexi Classic and Flexi Soft Gateways with Partnumbers 1042193, 1042964, 1044078, 1044072, 1044073, 1044074, 1099830, 1099832, 1127717, 1069070, 1112296, 1051432, 1102420, 1127487, 1121596, 1121597 allows an unauthenticated remote attacker to influence the availability of the device by changing the IP settings of the device via broadcasted UDP packets.
Missing authentication for critical function exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to execute some critical functions without authentication, e.g., rebooting the product.
SiYuan is a personal knowledge management system. Prior to version 3.6.2, the SiYuan kernel WebSocket server accepts unauthenticated connections when a specific "auth keepalive" query parameter is present. After connection, incoming messages are parsed using unchecked type assertions on attacker-controlled JSON. A remote attacker can send malformed messages that trigger a runtime panic, potentially crashing the kernel process and causing denial of service. Version 3.6.2 fixes the issue.
NLTK (Natural Language Toolkit) is a suite of open source Python modules, data sets, and tutorials supporting research and development in Natural Language Processing. In versions 3.9.3 and prior, `nltk.app.wordnet_app` allows unauthenticated remote shutdown of the local WordNet Browser HTTP server when it is started in its default mode. A simple `GET /SHUTDOWN%20THE%20SERVER` request causes the process to terminate immediately via `os._exit(0)`, resulting in a denial of service. Commit bbaae83db86a0f49e00f5b0db44a7254c268de9b patches the issue.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode.
An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via HTTP.
An unauthenticated remote attacker can access a URL which causes the device to reboot.
An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (TCP).
The reminder module lacks an authentication mechanism for broadcasts received. Successful exploitation of this vulnerability may affect availability.
An issue in the component tpi_systool_handle(0) (/goform/SysToolReboot) of Tenda W6-S v1.0.0.4(510) allows unauthenticated attackers to arbitrarily reboot the device.
An issue in the component tpi_systool_handle(0) (/goform/SysToolRestoreSet) of Tenda W6-S v1.0.0.4(510) allows unauthenticated attackers to arbitrarily reboot the device.
BKG Professional NtripCaster 2.0.39 allows querying information over the UDP protocol without authentication. The NTRIP sourcetable is typically quite long (tens of kBs) and can be requested with a packet of only 30 bytes. This presents a vector that can be used for UDP amplification attacks. Normally, only authenticated streaming data will be provided over UDP and not the sourcetable.
A denial of service vulnerability exists in the Modbus TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted network packet can lead to denial of service. An attacker can send an unauthenticated packet to trigger this vulnerability.
An improper authentication for critical function issue in Hitachi Kokusai Electric Network products for monitoring system (Camera, Decoder and Encoder) and bellow allows attckers to remotely reboot the device via a crafted POST request to the endpoint /ptipupgrade.cgi. Security information ID hitachi-sec-2022-001 contains fixes for the issue.
In D-link DIR-816 A2_v1.10CNB04.img,the network can be reset without authentication via /goform/setMAC.