SAP NetWeaver Application Server Java Platforms Invoker Servlet does not require authentication, allowing for remote code execution via a HTTP or HTTPS request.
Apply updates per vendor instructions.
Due to missing authentication check in SAP Host Agent - version 7.22, an unauthenticated attacker can set an undocumented parameter to a particular compatibility value and in turn call read functions. This allows the attacker to gather some non-sensitive information about the server. There is no impact on integrity or availability.
SAP NetWeaver Application Server Java for Classload Service - version 7.50, does not perform any authentication checks for functionalities that require user identity, resulting in escalation of privileges. This failure has a low impact on confidentiality of the data such that an unassigned user can read non-sensitive server data.
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
An unauthenticated attacker over the network can attach to an open interface exposed through JNDI by the User Defined Search (UDS) of SAP NetWeaver Process Integration (PI) - version 7.50 and make use of an open naming and directory API to access services which can be used to perform unauthorized operations affecting users and data across the entire system. This allows the attacker to have full read access to user data, make limited modifications to user data, and degrade the performance of the system, leading to a high impact on confidentiality and a limited impact on the availability and integrity of the application.
SAP Solution Manager (Diagnostics Agent), version 7.2, does not perform the authentication check for the functionalities of the Collector Simulator, leading to Missing Authentication.
Standalone clients connecting to SAP NetWeaver AS Java via P4 Protocol, versions (SAP-JEECOR 7.00, 7.01; SERVERCOR 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50; CORE-TOOLS 7.00, 7.01, 7.02, 7.05, 7.10, 7.11, 7.20, 7.30, 7.31, 7.40, 7.50) do not perform any authentication checks for operations that require user identity leading to Authentication Bypass.
An unauthenticated user can attach to an open interface exposed through JNDI by the Messaging System of SAP NetWeaver Process Integration (PI) - version 7.50. This user can make use of an open naming and directory API to access services that could perform unauthorized operations. The vulnerability affects local users and data, leading to a considerable impact on confidentiality as well as availability and a limited impact on the integrity of the application. These operations can be used to: * Read any information * Modify sensitive information * Denial of Service attacks (DoS) * SQL Injection
SAP Solution Manager (JAVA stack), version - 7.20, allows an unauthenticated attacker to compromise the system because of missing authorization checks in the Upgrade Diagnostics Agent Connection Service, this has an impact to the integrity and availability of the service.
SAP Process Integration, business-to-business add-on, versions 1.0, 2.0, does not perform authentication check properly when the default security provider is changed to BouncyCastle (BC), leading to Missing Authentication Check
Due to missing authentication check, SAP Business one License service API - version 10.0 allows an unauthenticated attacker to send malicious http requests over the network. On successful exploitation, an attacker can break the whole application making it inaccessible.
SAP Solution Manager (JAVA stack), version - 7.20, allows an unauthenticated attacker to compromise the system because of missing authorization checks in the Upgrade Legacy Ports Service, this has an impact to the integrity and availability of the service.
SAP Startup Service, SAP KERNEL 7.45, 7.49, and 7.52, is missing an authentication check for functionalities that require user identity and cause consumption of file system storage.
SAP Solution Manager (JAVA stack), version - 7.20, allows an unauthenticated attacker to compromise the system because of missing authorization checks in the Outside Discovery Configuration Service, this has an impact to the integrity and availability of the service.
SAP NetWeaver System Landscape Directory, LM-CORE 7.10, 7.20, 7.30, 7.31, 7.40, does not perform any authentication checks for functionalities that require user identity.
The Simple Diagnostics Agent - versions 1.0 up to version 1.57, does not perform any authentication checks for functionalities that can be accessed via localhost on http port 3005. Due to lack of authentication checks, an attacker could access administrative or other privileged functionalities and read, modify, or delete sensitive information and configurations.
SAP Solution Manager (JAVA stack), version - 7.20, allows an unauthenticated attacker to compromise the system because of missing authorization checks in the SVG Converter Service, this has an impact to the integrity and availability of the service.
SAP NetWeaver AS Java for Deploy Service - version 7.5, does not perform any access control checks for functionalities that require user identity enabling an unauthenticated attacker to attach to an open interface and make use of an open naming and directory API to access a service which will enable them to access but not modify server settings and data with no effect on availability and integrity.
SAP PowerDesigner - version 16.7, has improper access control which might allow an unauthenticated attacker to run arbitrary queries against the back-end database via Proxy.
The Runtime Workbench (RWB) of SAP NetWeaver Process Integration - version SAP_XITOOL 7.50, does not perform authentication checks for certain functionalities that require user identity. An unauthenticated user might access technical data about the product status and its configuration. The vulnerability does not allow access to sensitive information or administrative functionalities. On successful exploitation an attacker can cause limited impact on confidentiality and availability of the application.
SAP Software Provisioning Manager 1.0 (SAP NetWeaver Master Data Management Server 7.1) does not have an option to set password during its installation, this allows an authenticated attacker to perform various security attacks like Directory Traversal, Password Brute force Attack, SMB Relay attack, Security Downgrade.
SAP Host Agent, version 7.21, allows an attacker to cause a slowdown in processing of username/password-based authentication requests of the SAP Host Agent, leading to Denial of Service.
SAP Solution Manager (Diagnostics Agent), version 720, allows unencrypted connections from unauthenticated sources. This allows an attacker to control all remote functions on the Agent due to Missing Authentication Check.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
In Totolink A3100R V5.9c.4577, multiple pages can be read by curl or Burp Suite without authentication. Additionally, admin configurations can be set without cookies.
An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot.
upgrademysqlstatus in databases/views.py in CyberPanel (aka Cyber Panel) before 5b08cd6 allows remote attackers to bypass authentication and execute arbitrary commands via /dataBases/upgrademysqlstatus by bypassing secMiddleware (which is only for a POST request) and using shell metacharacters in the statusfile property, as exploited in the wild in October 2024 by PSAUX. Versions through 2.3.6 and (unpatched) 2.3.7 are affected.
Emerson Dixell XWEB-500 products are affected by arbitrary file write vulnerability in /cgi-bin/logo_extra_upload.cgi, /cgi-bin/cal_save.cgi, and /cgi-bin/lo_utils.cgi. An attacker will be able to write any file on the target system without any kind of authentication mechanism, and this can lead to denial of service and potentially remote code execution. Note: the product has not been supported since 2018 and should be removed or replaced
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC-F Series CPU modules, MELSEC iQ-F Series, MELSEC iQ-R series CPU modules, MELSEC iQ-R series, MELSEC iQ-L series, MELSEC Q series, MELSEC-L series, Mitsubishi Electric CNC M800V/M80V series, Mitsubishi Electric CNC M800/M80/E80 series and Mitsubishi Electric CNC M700V/M70V/E70 series allows a remote unauthenticated attacker to execute arbitrary commands by sending specific packets to the affected products. This could lead to disclose or tamper with information by reading or writing control programs, or cause a denial-of-service (DoS) condition on the products by resetting the memory contents of the products to factory settings or resetting the products remotely.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request.
ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186).
Trustwave Secure Web Gateway (SWG) through 11.8.0.27 allows remote attackers to append an arbitrary public key to the device's SSH Authorized Keys data, and consequently obtain remote root access, via the publicKey parameter to the /sendKey URI.
Missing Authentication for Critical Function vulnerability in debug_post_set.cgi of D-Link DWR-932C E1 firmware allows an unauthenticated attacker to execute administrative actions.
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.
An issue was discovered in Atos Eviden iCare 2.7.1 through 2.7.11. The application exposes a web interface locally. In the worst-case scenario, if the application is remotely accessible, it allows an attacker to execute arbitrary commands with system privilege on the endpoint hosting the application, without any authentication.
A firmware update vulnerability exists in the login.cgi functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary firmware update. An attacker can send an unauthenticated message to trigger this vulnerability.
The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.
BAB TECHNOLOGIE GmbH eibPort V3 prior version 3.9.1 allow unauthenticated attackers access to /webif/SecurityModule to validate the so called and hard coded unique 'eibPort String' which acts as the root SSH key passphrase. This is usable and part of an attack chain to gain SSH root access.
A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution.
RaspberryMatic is an open-source operating system for HomeMatic internet-of-things devices. RaspberryMatic / OCCU prior to version 3.75.6.20240316 contains a unauthenticated remote code execution (RCE) vulnerability, caused by multiple issues within the Java based `HMIPServer.jar` component. RaspberryMatric includes a Java based `HMIPServer`, that can be accessed through URLs starting with `/pages/jpages`. The `FirmwareController` class does however not perform any session id checks, thus this feature can be accessed without a valid session. Due to this issue, attackers can gain remote code execution as root user, allowing a full system compromise. Version 3.75.6.20240316 contains a patch.
An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway component that if exploited allows attackers without any access to interact with the services and the post-authentication attack surface.
A vulnerability allows unauthorized access to functionality inadequately constrained by ACLs. Attackers may exploit this to unauthenticated execute commands potentially leading to unauthorized data manipulation, access to privileged functions, or even the execution of arbitrary code.
Trend Micro Apex One (2019), OfficeScan XG and Worry-Free Business Security (9.0, 9.5, 10.0) server contains a vulnerable service DLL file that could allow a remote attacker to execute arbitrary code on affected installations with SYSTEM level privileges. Authentication is not required to exploit this vulnerability.
Red Lion SixTRAK and VersaTRAK Series RTUs with authenticated users enabled (UDR-A) any Sixnet UDR message will meet an authentication challenge over UDP/IP. When the same message is received over TCP/IP the RTU will simply accept the message with no authentication challenge.
An issue was discovered on D-Link DAP-1360 revision F devices. Remote attackers can start a telnet service without authorization via an undocumented HTTP request. Although this is the primary vulnerability, the impact depends on the firmware version. Versions 609EU through 613EUbeta were tested. Versions through 6.12b01 have weak root credentials, allowing an attacker to gain remote root access. After 6.12b01, the root credentials were changed but the telnet service can still be started without authorization.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link DCS-960L v1.07.102. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HNAP service, which listens on TCP port 80 by default. When parsing the SOAPAction request header, the process does not properly validate the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the admin user. Was ZDI-CAN-8458.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
Victure PC530 devices allow unauthenticated TELNET access as root.