A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.
CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS.
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin.
In Totolink A3100R V5.9c.4577, multiple pages can be read by curl or Burp Suite without authentication. Additionally, admin configurations can be set without cookies.
An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot.
Emerson Dixell XWEB-500 products are affected by arbitrary file write vulnerability in /cgi-bin/logo_extra_upload.cgi, /cgi-bin/cal_save.cgi, and /cgi-bin/lo_utils.cgi. An attacker will be able to write any file on the target system without any kind of authentication mechanism, and this can lead to denial of service and potentially remote code execution. Note: the product has not been supported since 2018 and should be removed or replaced
An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request.
ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186).
Trustwave Secure Web Gateway (SWG) through 11.8.0.27 allows remote attackers to append an arbitrary public key to the device's SSH Authorized Keys data, and consequently obtain remote root access, via the publicKey parameter to the /sendKey URI.
Missing Authentication for Critical Function vulnerability in debug_post_set.cgi of D-Link DWR-932C E1 firmware allows an unauthenticated attacker to execute administrative actions.
BAB TECHNOLOGIE GmbH eibPort V3 prior version 3.9.1 allow unauthenticated attackers access to /webif/SecurityModule to validate the so called and hard coded unique 'eibPort String' which acts as the root SSH key passphrase. This is usable and part of an attack chain to gain SSH root access.
A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution.
The Invoker Servlet on SAP NetWeaver Application Server Java platforms, possibly before 7.3, does not require authentication, which allows remote attackers to execute arbitrary code via an HTTP or HTTPS request, as exploited in the wild in 2013 through 2016, aka a "Detour" attack.
A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges.
Trend Micro Apex One (2019), OfficeScan XG and Worry-Free Business Security (9.0, 9.5, 10.0) server contains a vulnerable service DLL file that could allow a remote attacker to execute arbitrary code on affected installations with SYSTEM level privileges. Authentication is not required to exploit this vulnerability.
Control Web Panel Missing Authentication Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Control Web Panel. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of authentication within the web interface. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of a valid CWP user. Was ZDI-CAN-20582.
SAP Solution Manager (User Experience Monitoring), version- 7.2, due to Missing Authentication Check does not perform any authentication for a service resulting in complete compromise of all SMDAgents connected to the Solution Manager.
An issue was discovered on D-Link DAP-1360 revision F devices. Remote attackers can start a telnet service without authorization via an undocumented HTTP request. Although this is the primary vulnerability, the impact depends on the firmware version. Versions 609EU through 613EUbeta were tested. Versions through 6.12b01 have weak root credentials, allowing an attacker to gain remote root access. After 6.12b01, the root credentials were changed but the telnet service can still be started without authorization.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link DCS-960L v1.07.102. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HNAP service, which listens on TCP port 80 by default. When parsing the SOAPAction request header, the process does not properly validate the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the admin user. Was ZDI-CAN-8458.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
Victure PC530 devices allow unauthenticated TELNET access as root.
Super Micro SuperDoctor 5, when restrictions are not implemented in agent.cfg, allows remote attackers to execute arbitrary commands via NRPE.
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
In ONAP MSB through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the StorageNode service, which listens on TCP port 9075 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26156.
In ONAP SO through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
In ONAP CLI through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
Due to unencrypted and unauthenticated data communication, the wireless barcode scanner Inateck BCST-60 is prone to keystroke injection attacks. Thus, an attacker is able to send arbitrary keystrokes to a victim's computer system, e.g., to install malware when the target system is unattended. In this way, an attacker can remotely take control over the victim's computer that is operated with an affected receiver of this device.
The nd-restaurant-reservations plugin before 1.5 for WordPress has no requirement for nd_rst_import_settings_php_function authentication.
Improper Access Control in the RCP+ server of the Bosch Video Recording Manager (VRM) component allows arbitrary and unauthenticated access to a limited subset of certificates, stored in the underlying Microsoft Windows operating system. The fixed versions implement modified authentication checks. Prior releases of VRM software version 3.70 are considered unaffected. This vulnerability affects VRM v3.70.x, v3.71 < v3.71.0034 and v3.81 < 3.81.0050; DIVAR IP 5000 3.80 < 3.80.0039; BVMS all versions using VRM.
AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the DaoService service, which listens on TCP port 9074 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26158.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/setSysAdm to edit the web or system account without authentication.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin.