A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.
An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access.
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
Use-after-free vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via unspecified long strings that trigger heap memory corruption.
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data.
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
A Command Injection vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.
A Command Injection vulnerability exists in the web-based GUI of the 1st Gen PelcoSarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.
Command injection vulnerabilities in the underlying CLI service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba's Access Point management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system.
TOTOLINK X18 V9.1.0cu.2024_B20220329 was discovered to contain a command injection vulnerability via the pid parameter in the disconnectVPN function.
Command injection vulnerabilities in the underlying CLI service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba's Access Point management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system.
An issue was discovered in Anyka Microelectronics AK3918EV300 MCU v18. A command injection vulnerability in the network configuration script within the MCU's operating system allows attackers to perform arbitrary command execution via a crafted wifi SSID or password.
Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetPppoeServer. This vulnerability allows attackers to execute arbitrary commands via the pppoeServerIP, pppoeServerStartIP, and pppoeServerEndIP parameters.
Tenda AX3 v16.03.12.10_CN was discovered to contain a command injection vulnerability in the function WanParameterSetting. This vulnerability allows attackers to execute arbitrary commands via the gateway, dns1, and dns2 parameters.
An issue was discovered in SeaCMS <=12.9 which allows remote attackers to execute arbitrary code via admin_ping.php.
Multiple OS command injection vulnerabilities exist in the login.cgi set_sys_init() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary code execution. An attacker can make an unauthenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists within the `restart_hour_value` POST parameter.
Multiple OS command injection vulnerabilities exist in the login.cgi set_sys_init() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary code execution. An attacker can make an unauthenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists within the `restart_min_value` POST parameter.
An attacker is able to remotely inject arbitrary commands by sending especially crafted packets destined to the PAPI (Aruba Networks AP Management protocol) UDP port (8211) of access-pointsor controllers in Aruba 9000 Gateway; Aruba 7000 Series Mobility Controllers; Aruba 7200 Series Mobility Controllers version(s): 2.1.0.1, 2.2.0.0 and below; 6.4.4.23, 6.5.4.17, 8.2.2.9, 8.3.0.13, 8.5.0.10, 8.6.0.5, 8.7.0.0 and below ; 6.4.4.23, 6.5.4.17, 8.2.2.9, 8.3.0.13, 8.5.0.10, 8.6.0.5, 8.7.0.0 and below.
GL-iNet products AR750/AR750S/AR300M/AR300M16/MT300N-V2/B1300/MT1300/SFT1200/X750 v4.3.11, MT3000/MT2500/AXT1800/AX1800/A1300/X300B v4.5.16, XE300 v4.3.16, E750 v4.3.12, AP1300/S1300 v4.3.13, and XE3000/X3000 v4.4 were discovered to contain a vulnerability can be exploited to manipulate routers by passing malicious shell commands through the s2s API.
inventory in Atos Unify OpenScape 4000 Platform and OpenScape 4000 Manager Platform 10 R1 before 10 R1.34.4 allows an unauthenticated attacker to run arbitrary commands on the platform operating system and achieve administrative access, aka OSFOURK-23552.
Tenda AX3 v16.03.12.10_CN was discovered to contain a command injection vulnerability in the function mDMZSetCfg. This vulnerability allows attackers to execute arbitrary commands via the dmzIp parameter.
Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetQvlanList. This vulnerability allows attackers to execute arbitrary commands via the qvlanIP parameter.
Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetIpGroup. This vulnerability allows attackers to execute arbitrary commands via the IPGroupStartIP and IPGroupEndIP parameters.
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function.
TOTOLINK X18 V9.1.0cu.2024_B20220329 was discovered to contain multiple command injection vulnerabilities via the rtLogEnabled and rtLogServer parameters in the setSyslogCfg function.
TOTOLINK X18 V9.1.0cu.2024_B20220329 was discovered to contain a command injection vulnerability via the command parameter in the setTracerouteCfg function.
OPTILINK OP-XT71000N V2.2 is vulnerable to Remote Code Execution. The issue occurs when the attacker sends an arbitrary code on "/diag_ping_admin.asp" to "PingTest" interface that leads to COMMAND EXECUTION. An attacker can successfully trigger the COMMAND and can compromise full system.